INTRODUCTION 

Thank you for purchasing one of our products. The cushions have been designed and manufactured 

to meet all your needs for practical, correct and safe use. This manual contains some suggestions for 
a correct use of the device and valuable advice for your safety. We recommend to read all the manual 
carefully before using the item. In case of any doubts, please contact the dealer, who will be able to 
advise you correctly. 

Note: Check all parts to verify it won’t be any shipping damage. In case of any damages, do not use 

it. Contact the dealer for further instructions. 

 
DECLARATION OF CONFORMITY 

DEMARTA VIRGINIO SAS declare under sole responsibility that the products that belong to walker range 

are in accordance with the European Directive on Medical devices (93/42/EEC).  

DEMARTA VIRGINIO SAS guarantees and declared under sole responsibility what follow: 
• The devices under discussion satisfy the essential requisites requested by the I enclosure  directive 

93/42/CEE as laid down by the VII enclosure of the above mentioned Directive. 

• The devices under discussion belong to class I. 
• It is NOT PERMITTED to use this devices outside the intended use envisaged by DEMARTA VIRGINIO SAS. 
• The articles also comply with all European standards applicable to them. 

 
INTENDED USE 

The cushion air is intended for the prevention of pressure sores in subjects who must maintain a sitting 
position for prolonged periods of time. 
Intended  use:  the  products  have  been  made  for  use  both  in  a  sanitary  and  private  environment, 
according to the medical prescription. 
Limitations of use: due to the type of material used and the medical prescription. 

 
WARNINGS 

• Beware of sharp objects ex. scissors. 
• Avoid exposure to the sun and flames. 
• Protect the pillow from contact with cigarette butts. 
• The maximum weight supported by the air bubble cushion is 140 kg. 
• Do not use the cushion if it is damaged. 
• Make sure there are no objects resting on the cushion before sitting. 

 
DESCRIPTION 

CUSHION AIR is an air bubble cushion with a micro-interchange structure. It is made of waterproof PVC 
air to ensure constant pressure is maintained inside. The cover is characterized by a support surface in 
Jersey, breathable and bielastic polyester; a honeycomb structure on the sides, a non-slip base, 
carrying handle, zips on 3 sides and laces for anchoring to the wheelchair. Therapeutic capacity 140 
Kg. 
Inflation pump included. 
The models available are: 
• Profile 6 cm, one valve.   • Profile 10 cm, one valve. 
• Profile 6 cm, two valves.  • Profile 10 cm, two valves. 

 

Summary of Contents for CUSHION AIR

Page 1: ...Demarta Virginio SAS di Belletti Virginio e C via Bozzalla 20 13814 Pollone BI P IVA 01530570025 C F 00459790010 Tel 39 015 9555440 info demarta com MANUALE D USO CUSHION AIR...

Page 2: ...va I dispositivi in oggetto sono da considerarsi come appartenenti alla classe I NON CONSENTITO utilizzare e o installare i dispositivi in oggetto al di fuori della destinazione d uso prevista dalla D...

Page 3: ...6 x 50 x 10 05 01 1V5056 6 50 x 56 x 6 05 01 2V5056 6 50 x 56 x 6 05 01 1V5056 10 50 x 56 x 10 05 01 2V5056 10 50 x 56 x 10 05 01 1V5656 6 56 x 56 x 6 05 01 2V5656 6 56 x 56 x 6 05 01 1V5656 10 56 x 5...

Page 4: ...ione possibile con disinfettanti diluiti al 5 anche a base alcolica Manutenzione e Pulizia Fodera Lavaggio Max 40 C Non Stirare Non Candeggiare Non Utilizzare l Asciugatrice CONDIZIONI DI SMALTIMENTO...

Page 5: ...Demarta Virginio SAS di Belletti Virginio e C via Bozzalla 20 13814 Pollone BI P IVA 01530570025 C F 00459790010 Tel 39 015 9555440 info demarta com USER MANUAL CUSHION AIR...

Page 6: ...vices under discussion belong to class I It is NOT PERMITTED to use this devices outside the intended use envisaged by DEMARTA VIRGINIO SAS The articles also comply with all European standards applica...

Page 7: ...x 50 x 6 05 01 1V5650 10 56 x 50 x 10 05 01 2V5650 10 56 x 50 x 10 05 01 1V5056 6 50 x 56 x 6 05 01 2V5056 6 50 x 56 x 6 05 01 1V5056 10 50 x 56 x 10 05 01 2V5056 10 50 x 56 x 10 05 01 1V5656 6 56 x...

Page 8: ...ass the valves through the respective holes on the cover Close the zip carefully The cushion is ready for use CLEANING Cushion Maintenance and Cleaning Disinfection possible with 5 diluted disinfectan...

Reviews: