8.5.3
Removing the chain collector box
Fig. 38
–
Unscrew and remove service cover (1).
–
Place bag (2) with the control cable on the top of the chain hoist.
–
Disconnect spring (3) and place it in the recess in the chain collector box.
–
Remove retaining spring (4) from pin (5) and remove the pin. While doing so, hold the chain collector.
–
Place chain collector box (6) on the ground.
8.5.4
Operating limit switches (standard for DC-Com 10 with 2/1 reeving)
8.5.4.1
Checking operating limit switches
DANGER
Danger of broken chain and falling load
The chain may break and loads may fall if the emergency limit position limiter is frequently approached.
214
80
2 44/291
113
71
Summary of Contents for DC-Com 1
Page 39: ...214 802 44 291113 39...
Page 45: ...Fig 21 214 802 44 291113 45...
Page 46: ...Fig 22 46 214 802 44 291113...
Page 102: ...214802ET indd 291113 102 12 Spare parts 12 1 Overview 1 1 reeving 2 1 reeving 42764247 eps...
Page 104: ...214802ET indd 291113 104 12 3 Parts on the gearbox 42763847 eps...
Page 106: ...214802ET indd 291113 106 12 4 Chain drive 42764346 eps 1 1 reeving 2 1 reeving...