background image

I-1246 

 

Page 5 of 9 

Rev. E-43816                                  3/23/18 

Use U

p

 and Down Button to

 mov

e

 throu

g

h menu 

Programming for Drain Application

 

 

MONDAY 11:23 

POWER LEVEL 100% 

CLOCK STYLE 

24hr 

CURRENT TIME 

11:24 

CURRENT DAY 

MONDAY 

SELECT MODE 

DRAIN 

SELECT   SMTWTFS 
DAYS ON  

*******

 

CHARGES PER DAY 

02 

CHARGE#   START 

01    01:30 AM 

RUN TIME mm:ss 

01:30 

ENTER PASSCODE 

0000 

Idle screen – Day, Time and Power Level for Battery Life Option – 
Press ENTER to access programming.  

Enter the passcode to access programming and press ENTER – 
default passcode out of the box is “0000” 

AUDIBLE ALERT 

NO 

CHANGE PASSCODE 

0000 

EXIT PROGRAMMING 

PRESS ENTER 

Select 12 or 24hr clock format - Press ENTER, use LEFT and 
RIGHT to select 12hr or 24hr clock format, Press ENTER to save. 

What is the current time? Press ENTER. Use LEFT and RIGHT to 
move to hours and minutes and UP and DOWN to change the hour 
and minute.  Press ENTER to save. 

What is the current day of the week? Press ENTER. Use UP and 
DOWN button to select the day.  Press ENTER to save. 

Is this a Drain or Deodorizer application? Press ENTER, use LEFT 
and RIGHT button to select Drain or Deodorizer. Press ENTER to 
save.    

What days should the pump run? Press ENTER, use LEFT and 
RIGHT to move through days.  The asterisk (*) signifies that the 
pump will run that day.  Use UP to add asterisk and DOWN to 
remove the asterisk. Press ENTER to save. 

How many pump operations per day? Press ENTER, use UP and 
DOWN to move through choices. Press ENTER to save up to 24 
operations max. 

When should the pump operations run? Press ENTER, use UP and 
DOWN to select the Charge# and then use the LEFT and RIGHT to 
move the time and UP and DOWN to change the charge the start 
time.  Press ENTER to save up to 24 operations max. 

How long should the pump run? Press ENTER, use LEFT and 
RIGHT to select minutes and seconds.  Press ENTER to save. Run 
Time applies to all charges, with maximum of 10 minutes. 

Is an audible beep desired for alerting low battery or out of 
chemical product (out of product sensor required)? Press ENTER, 
use UP and DOWN to select Yes or No.  Press ENTER to save.

Modify the passcode? Press ENTER, use LEFT and RIGHT to 
select the digit, UP and DOWN to change the value of digit. Press 
ENTER to save. 

Press ENTER to exit programming. 

Summary of Contents for Trapper

Page 1: ...parish provincial or other agencies It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation For questions c...

Page 2: ...Kit List Installation and Accessory Parts for Drain Applications No Part No Description Trapper Drain Trapper OC 1 25 235 1 Compression Fitting Drain system 1 2 25 215 Spray Nozzle Deodorizing system...

Page 3: ...cell batteries or 115 VAC or 100 240 VAC wall adapters Motor Solenoid Rating 12VDC 1 25A max Pump Rate 14 oz min 420 ml min Enclosure Material ABS Shipping Wt AC 2 3 kg 5 0 lbs Shipping Wt Battery 2 8...

Page 4: ...ell heavy duty batteries in the battery holder 4 Mount the Trapper pump and battery enclosures on the mounting bracket 5 Install injection fitting drain application or spray nozzle deodorizing applica...

Page 5: ...rizer application Press ENTER use LEFT and RIGHT button to select Drain or Deodorizer Press ENTER to save What days should the pump run Press ENTER use LEFT and RIGHT to move through days The asterisk...

Page 6: ...orizer application Press ENTER use LEFT and RIGHT button to select Drain or Deodorizer Press ENTER to save What days should the pump run Press ENTER use LEFT and RIGHT to move through days The asteris...

Page 7: ...w 5 5 81 147 1 5 Button Rubber Keypad 1 6 25 228 1 Pump Housing Rear 1 7 25 231 1 Trapper Control Board 1 8 25 227 1 Pump Mounting Bracket 1 9 25 252 1 Power Inlet DC 1 10 25 253 1 Power Cable Motor 1...

Page 8: ...QTY 1 25 222 1 Battery Box Mounting Bracket 1 2 81 183 7 Cable Strain Relief 1 3 25 224 Battery Housing Front 1 4 25 223 1 Battery Housing Rear 1 5 81 16 1 Cable Tie 2 6 25 251 1 Battery Holder w DC P...

Page 9: ...ne year from the date of manufacture This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals corrosion physical abu...

Reviews: