DEMA TITAN II T-812-DL Manual Download Page 8

 

 
 
 
 

 

 

 

 

I-1024 
Rev. G-4

SWIT
INAC

MACH
CONV

TRIG
DETE
NOTE

RINSE
during
mode,
initial 
The de
additiv
rinse a
DETE

DIRT
INAC

 

* The 

COM

NOTE

with th
symbo

ALAR

CONC

20

FEED

ALAR

00:20 

FEED

10:00 

RECH

00:01 

43816 

TCHOVER AL

CTIVE 

HINE TYPE 

VEYOR 

GGER MODE 

ERGENT/RIN

E: 

Four trigger

E ONLY, requ

g the rinse trigg

 the wash trigg

charge will be

etergent operat

ve is dispensed

and the deterge

ERGENT/RINS

TY H2O ALAR
CTIVE 

dirty H2O al

PANY NAME

E: 

Pressing 

he 

 and 

 ke

ols.   Press 

RM VOLUME

0 – 10

C. SET POINT

00 0 

– 

100

D RATE 

1 – 10

RM DELAY 

mm:ss 

D LIMIT 

mm:ss 

HARGE TIME

mm:ss 

  3/2







LARM 

NSE 

r options are av

uires only a rins

ger when using
ger may be con

e dispensed dur

tes normally. In

d following the

ent functions to
SE is the defau

RM 



 

 

arm will ‘rese

 displays th

eys (press and 

to save. 

T  

(Co

00 

(Co

0 The

(Th
star
be s

(Th
pum

(Th
cha
set 

23/18 

DEMA Engi
St. Louis, M

SWITCH
ACTIVE

SWITCH

MACHIN
DOOR

TRIGGE

NO TRIG

vailable. DETE

se trigger. Rins

g RINSE ONLY
nnected to the m

ring the fill cyc

n conveyor mo

e loss of the det

o run whenever

ult mode. 

DIRTY H
ACTIVE

 

et’ after the ta

he current com

hold down to 

oncentration se

ontrols the rate

e default is 5.)

he time delay b

rts when the co

set from 5 seco

he time delay fr

mp is stopped. 

his is the time d
arge is dispense

from 1 sec to 5

SERVICE 
DISPENSER

ineering 

MO 

HOVER ALARM

E



H MESSAGE 

(T

di
E
to
D

NE TYPE

ER MODE

GGER INPUT

ERGENT/RINS

se functions op

Y trigger. Whe

machine fill va
cle. DETERGE

ode, the rinse ru

tergent trigger.

r there is powe

H20 ALARM

E

nk has been d

mpany name and

‘fast cycle’). T

et point default 

e of approach t

before a deterge

oncentration is 

onds to 10 min

rom when the c

It may be set f

detergent will b

ed. This time is

5 min. The def

R SOON 

(This allows

Auto Switch
switches fro
Setting it to

This allows the

isplayed when

Enter displays th

o be changed, l

DOWN 

 keys

(This allows 

mode. The s

Programmin

TRIGGER

T DETERGE

SE allows the t

perate normally

en using RINSE

alve. When the 

ENT ONLY, re

uns with the tr

. NO TRIGGE

er to the dispen

Press “EN
how long 
alarm soun

drained and re

 (Insert 

d allows it to b

The empty ‘spa

is 50) 

to the set point

ent alarm will 

below the set p

nutes. The defau

concentration a

from 5 sec to 1

be dispensed in

s not used in th

fault is 1 secon

Page 8

s a message to b

hover is enable

om concentrati

o inactive will i

e entry of a cus

n a switch over 

the current mes

letter by letter, 

s. 

the selection o

status may only

ng mode. Conv

MODE 

ENT ONLY  R

traditional two

y and detergent

E ONLY trigg

fill valve beco

equires only a d

rigger. In door 

ER INPUT, wil

nser. 

NTER” and inpu

dish machine s

nds.

* (1 hr. m

efilled. (All mo

your company

be changed, let
ace’ is between

t to help contro

sound in conce
point and is no
ult setting is 5 

alarm starts un

0 min. The def

n probeless mo

he no trigger do

nd.) 

8 of 16 

be displayed if

ed and the cont

ion to probeles

inhibit the disp

stom message t

occurs. Pressin

ssage and allow

with the UP 

of Door or Con

y be changed in

veyor is the def

TRIGGER MO

RINSE ONLY

o trigger input. 

t functions occ

er in PROBEL

omes active, th

detergent trigg

mode, the rins
l cause both th

ut time to indic

should run befo

in – 4 hrs. ma

odes) 

y name here.) 

tter by letter, 

n the

 and ! 

ol overshoot. 

entration mode

ot increasing. It

minutes.) 

ntil the detergen

fault is 10 min.

ode after the in

oor mode. It m

trol 

s. 

play.) 

to be 

ng 

ws it 

 and 

nveyor 

fault.) 

ODE 

cur 

LESS 

he 

ger. 

he 

cate

fore

ax)

e. It 

t may 

nt 

.) 

itial 

may be 

Summary of Contents for TITAN II T-812-DL

Page 1: ...form to loca icating tee is to state of Wiscon OTECTIVE CL CTS WAREW T 813 S elivery functio ply that will acc of 20V 500V 5 as an Auto Sw ver feature virtu meet all applica incial or other ctrical co...

Page 2: ...8 ID LDPE detergent 16 ft x 1 16 ID Vinyl rinse san 1 1 1 1 1 2 1 2 C 12V1K Conductivity Cell 1 1 1 1 904 8KY Sanitizer Check Valve 1 1 Operational Requirements For Indoor Use Only Main Power 100 VAC...

Page 3: ...M MAGNE INDUCT 6 PRODU POWER OWN RIPTION ROL BOARD ER BOARD W R SUPPLY inc TING BRACK II HOLE PLU PUMP AND M II LABEL KIT ER CABLE R E CABLE 15 MODULE AS R AND DETE NOID VALVE ER INPUT C MODULE JOIN...

Page 4: ...R BLO 2 ROLLER BLO ENT SQUEEZE TU ITIZER SQUEEZE PU 60 RPM GEAR 15 RPM GEAR MO SILICONE LUBE VE ASS DES SOLENOID VA DES VAL MACHINE S VALVE ASSEMB G FITTING STRA PP JG FITTING ELB SS SCR CABLE VALVE B...

Page 5: ...le ng 25 68 20 i 0 12 SV1 whic quired and if d needed to go fr length require e elp to install th fety purposes per the dish m ROUNDED E nnection points rd and cable T he wiring diagra field when the...

Page 6: ...WH BLA RED GRE ing of the unit with DEMA E three steps wil rogrammed in hine manufactu dish machine p via the wash nd white wire n should receiv wires to the dis a rinse trigger OWN WASH ITE WASH ACK...

Page 7: ...oncentration pr ess mode settin settings simula ount of time in mount of time ften to recharg ode for less than 2 ge harge is 1 min o 8 s it will appear ht Use and to step throug within 10 seco page 1...

Page 8: ...is onds to 10 min rom when the c It may be set f detergent will b ed This time is 5 min The def R SOON M This allows Auto Switch switches fro Setting it to This allows the isplayed when Enter display...

Page 9: ...ting and the deterge prompts t one pressing nductivity A c chemical capsu asure the condu fficiently differ the same a fai The set point sh ed to be about be recommend rinse motor m t The default i fr...

Page 10: ...nt cover of the dispenser Take the four screws out to lift the board out There are two solder points on the back of the board Connect them together with an insulated wire and turn on the power Next tu...

Page 11: ...tion r three minute cle will termina ESS allows yo NOTE T directly t heading Press the headi programm m Access programmable G PRESS GET TO THE es RIME PRIMING mp if it is not s PRIME PRIMIN ZER PRIMIN...

Page 12: ...uto S SWITCH ACTIVE MACHIN DOOR TRIGGE NO TRIG vailable DETE se trigger Rins ENT ONLY re inse runs with t trigger NO TR power to the d DIRTY H ACTIVE ays the current and hold down NTER USER CO DEMA St...

Page 13: ...ow the block RETURN TO SYSTEM ACCESS RINSE SPEED 50 0 100 RINSE DELAY 1 0 15s RINSE LIMIT 15 70s RINSE LENGTH The length of the rinse cycle for one rack 12 5 75s PROBELESS PARAMETERS 1 0 10 DWELL TIME...

Page 14: ...OTE 0000 0000 LEFT TO RESET RETURN TO SYSTEM ACCESS NOTE This screen displays the total switchover count for OVER and UNDER feedings The number below OVER is the count of switchovers caused by the dis...

Page 15: ...ult for this initial charge is 15 seconds This may not be enough time for the wash tank to reach its concentration level Watch the wash tank reach its level and determine the time it takes then use th...

Page 16: ...the probe cable connection points and make sure it is connected properly 3 Clean Probe 4 Check set point in programming Pump under feeding 1 If in concentration or probe mode the probe cable may be s...

Reviews: