Installation  

Mount the unit no higher than 6 feet from the chemical container. Take into account the proximity to the chemical, 
drain, and power for the unit. Use the included screw and anchor kit to secure the mounting bracket to the wall and 
then mount the unit on the wall. Then cut the tubing to the proper length to reach from the chemical container to the 
unit and the unit to the drain where the chemical is being dispensed.  
 

Squeeze Tube Installation 

Install the squeeze tube by 
removing the pump cover by 
depressing the tab on the 
front of the unit. (1) Place 
one end of the squeeze tube 
on the left side of the pump 
in the slot provided. (2) 
Wrap the squeeze tube 
around the rollers of the 
pump. (3) Then stretch the 
squeeze tube so that the end 
of the tube goes into the slot 
provided. (4) Replace the 
cover on the pump.  

 

   

 (1)                       (2) 

                 (3)   

                 (4)

 

 

Retaining Clip 

There is a clip on the bottom of the unit. This is to help relieve strain on 
the power cord.  Place the power cord through this strain relief to help the 
power cord from coming unplugged from the unit.  
 

 

 

Clasp Close Pump Heads 

     The pump heads have an added feature which will 
help to ensure the pump head is installed properly. 
When pushing the pump head on be sure to see the 
clip is fully covering the notch as seen in the first 
picture. If the tab is not fully engaged, there is a 
possibility of it popping off the pump head as seen in 
the second picture.    

 

Operation  

Programming the Dispenser - Reset timer before programming.

 

Note:  If a mistake is made during the programming, simply push the 
reset button and start over.  

A.

 

12 Hour or 24 Hour (Military) Mode 

Hold the “Clock” button down for 5 seconds or more to change back & 
forth to between the 12 & 24 hour modes. 

B.

  Set the Time and Day

 

When the unit arrives the display may be blank or may display a time. Plug the 
unit into an outlet before programming. 

NOTE: Make sure that the bar in the bottom of the display is over the word 
OFF – if it isn’t, press the MANUAL button until it is. 

1.

 

To set the time and day of the week, hold the CLOCK button in and press the day, hour, and minute buttons 
until the proper day, hour, and minute is achieved. 

Note:  The days will be across the top of the screen and will advance as the button is hit. The time 
must be set to AM and PM it is in the left top corner of the display. By holding in the Day, Hour, or 
Minute button for three seconds the setting will continue to advance until the button is released.  
 