DEMA MixRite TF-25 Quick Start Manual Download Page 2

  

  2

MixRite TF 25 Proportional Dosing Injectors 

 

We congratulate you on your purchase of one of MixRite's excellent products. 

 It is important to devote a few minutes to carefully reading the explanations and recommendations 

in this user's manual in order to get the most from the proportioning dosing injector. 

 

Operation of the injector 

The proportioning dosing injector is fitted on the water line. The flow of water passing through the 

injector activates it and causes the pumping of liquid additive and inserts it in a relative quantity 

into the water line. 

 

The MixRite TF 25 proportioning dosing 

injector will operate in the following 

conditions: 

The flow rate of the water passing through the MixRite TF 25 is between 2 and 25 m

3

/hour (530-

6600 gal/hour). 

The water pressure is between 1 and 8 bar (14-120 PSI). 

 

Head loss for MixRite TF 25: Minimum flow 0.1 Bar – Maximum flow 1.5 Bar  

The water & air temperature are not less than 4ºC (40ºF) and not more than 40ºC (104ºF)   

The flow rate of the additive can be adjusted relative to the flow rate of the water in the range of 

0.1% to 1% for Model 001 and of 0.3% to 2.5% for Model 002 and in the range of 1% to 5.5% for 

Model 005. 

 

Installation of the 
injector

 

 

Option A: Wall 
mounting bracket 

(Supplied as standard)  

The package should 

contain: 

 

A proportioning dosing 

injector to which are 

attached two couplings 

for a 63mm plastic pipe  

Or two 2" threaded 

couplings. 

 

A flexible suction tube 

to which is attached a 

flat 1" seal and a filter. 

 

A Bracket, 4 SS screws 

M8*45, 4 SS nuts M8. 

 

Spanner for TF cover 

nut.  

 

User's manual 

Summary of Contents for MixRite TF-25

Page 1: ...MixRite TF 25 ...

Page 2: ...ter passing through the MixRite TF 25 is between 2 and 25 m3 hour 530 6600 gal hour The water pressure is between 1 and 8 bar 14 120 PSI Head loss for MixRite TF 25 Minimum flow 0 1 Bar Maximum flow 1 5 Bar The water air temperature are not less than 4ºC 40ºF and not more than 40ºC 104ºF The flow rate of the additive can be adjusted relative to the flow rate of the water in the range of 0 1 to 1 f...

Page 3: ...and a filter A stand comprising 4 legs 2 arched braces 4 bolts with 8 mm nuts and 4 bolts with 6mm nuts Spanner for TF cover nut User s manual To assemble the stand Insert the narrow part of the leg into the opening in the tube in the arched brace Make sure that the holes in the leg are opposite the holes in the arched brace Insert the 6mm bolt and tighten the nut Repeat with the other legs Attach...

Page 4: ...tion tube Insert the flat seal into the nut of the coupling on the end of the tube 1 Thread and tighten the nut to the inlet valve on the underside of the injector Make sure that the nut is threaded and tightened properly 2 3 ...

Page 5: ...t the pipe into the inlet and outlet opening and push hard so that the pipe penetrates and passes the seal and is stopped at the end of the route To ease Insertion apply a little silicon grease to the end of the pipe Push the white ring until it contacts the threaded part and tighten the nut Repeat the process in order to connect the pump to the pipe on the other side Optional Special grip ring fo...

Page 6: ...ng of the line 1 water filter of 200 mesh 2 backflow prevention valve 3 must be fitted to a drinking water line according to local regulations in order to prevent entry of chemicals to the drinking water A pressure reducer 4 a T connection for diversion from the main line to the bypass a valve 5 on the bypass before the inlet to the proportioning dosing injector a valve 6 after the outlet from the...

Page 7: ... a regulation valve 6 the injector a non return valve 7 after the outlet from the injector and a return connection to the main line 8 anti vacuum valve 9 Both sides of the instillation must be identical Connection to the additive tank The suction tube should be connected to the additive tank preferably about 5cm above the bottom diagram A The liquid additive must pass through a chemical resistant ...

Page 8: ...site direction to the water flow direction Fit the injector with the arrows in the direction of flow s e v l a v e h t n e p O d e s o l c e r a s e v l a v t e l t u o d n a t e l n i e h T r e t l i f e h t n a e l C d e k c o l b s i r e t l i f t e l n i e h T The injector does not work e v l a v n i a m e h t n e p O e r u s s e r p e t a i r p o r p p a e h t t a w o l f r e t a w o n s i e ...