background image

I-1022 

 

Page 2 of 8 

Rev. B-36992      6/17/11 

Packing List 

X = included in kit 

Part Number 

Description 

DNE.DL 

DNE.LL. 

DNE.DLL 

DNE.LLL 

904.8T 

RINSE CHECK VALVE ¼” OD TEFLON BALL 

80.55 

LIQUID DETERGENT FEED INJECTION ELBOW 

 

 

81.312.1 

SPLIT PICK UP TUBE STIFFENER 

25.68.20 

20 FT ¼” OD LDPE TUBING 

C.12B 

CONDUCTIVITY 

CELL 

X X X X 

100.12.SV1 

VINYL 

RINSE 

TUBING 

X X X X 

58.5 

OVERFLOW ELBOW KIT – DRY DETERGENT 

 

 

904.8KY 

RINSE CHECK VALVE ¼” COMP X 1/8” NPT KYNAR 

 

 

81.16.1 

TIE WRAPS 8” LONG 

I1022 

INSTRUCTION 

SHEET 

X X X X 

Operational Requirements 

 

For indoor use only 

Main Power 

100-265VAC 50/60 Hz 1.5A 

Motor/Solenoid Rating 

24VDC 

Enclosure Material 

ABS 

Environmental Temp. 

0-40°C 

32-104°F 

Product Weight 

4.08 KG 

9.0 LB 

The integrity and operational characteristics of this unit are not guaranteed outside the above 

mentioned parameters. Use of this unit outside of these parameters nullifies warranty. 

This unit will only accept up to 265 VAC. It cannot accept over this amount. If more than 265 
VAC is supplied to this unit, critical damage will occur.  

 

Overall Size 

 

Summary of Contents for Master Nitro Express

Page 1: ...products must meet all applicable electrical codes and regulations established by national city county parish provincial or other agencies It is possible that electrical codes and regulations require...

Page 2: ...VALVE COMP X 1 8 NPT KYNAR X X 81 16 1 TIE WRAPS 8 LONG 5 5 8 8 I1022 INSTRUCTION SHEET X X X X Operational Requirements For indoor use only Main Power 100 265VAC 50 60 Hz 1 5A Motor Solenoid Rating...

Page 3: ...CT 81 118 29 1 PUMP 2 SPRING ROLLER 60 RPM MOTOR ID KIT 80 59 60MK 60 RPM DETERGENT MOTOR 3 44 123 14B DM NITRO EXPRESS DETERGENT VALVE REPLACEMENT 81 118 29 2 PUMP 3 ROLLER FIXED 15 RPM MOTOR 1 8 ID...

Page 4: ...tall the sanitizer injection fitting 904 8KY if sanitizer is used into the rinse line tap provided by the manufacturer of the machine If a tap is not provided follow the manufacturer s recommendations...

Page 5: ...am for the unit This is the internal wiring of the unit Programming the Nitro Express Programming is done through the setting of dip switches and potentiometers knobs The following states how to progr...

Page 6: ...of elapsed time where no triggers have activated the dispenser 1 2 With the rinse limit turned on switch 7 and a rinse trigger active for Detergent more than 20 seconds an initial charge will be disp...

Page 7: ...The settings for the probe configuration are the same when the dispenser is being used in door or conveyor mode Detergent Concentration Level The detergent knob sets the concentration level or set poi...

Page 8: ...ble connection points and make sure it is connected properly 3 Clean Probe 4 Switch dip switch to low range or set knob to needed setting Pump under feeding 1 If in concentration or probe mode the pro...

Reviews: