background image

DEMA 151

 

FAUCET PROPORTIONER 

INSTALLATION INSTRUCTIONS

I-101 

 

  Pg. 

of 

Rev. C-41011    9/11/15 

 

I.

 

PARTS 

A.

 

Faucet Proportioner 

B.

 

¼” ID x 8 ft. long vinyl supply tubing, foot valve and ceramic weight 

C.

 

Metering Tips (2 ea.) 

 

II.

 

INSTALLATION

 

 
 

This product is designed only to be used as described in this instruction sheet.  Adhere to all warnings and 
cautions identified in this document.   

 

WARNING: 

Installations must conform to all local and national plumbing codes and use 

approved backflow prevention and pressure relief devices where required. 
 

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER 
IS NOT IN USE. 

 

Always read SDS for all chemicals used and follow personal protective guidelines.

 

 

 

Screw proportioner directly onto garden hose type faucets. Remove inlet adapters for mounting onto standard 
external aerator threads.  For other faucets, see parts break-down for adapter part numbers.  Select a metering tip (See 
section 4), and screw it into the inlet barb (Figure 1). 
 
Place the chemical container in a convenient location not more than 6 feet below the proportioner (greater lifts will 
reduce injection capacities).  Insert the vinyl supply tubing with the foot end into the chemical container.  Cut the 
vinyl tube to any convenient length that will allow it to extend from the bottom of the chemical container to the 
proportioner inlet barb.  (See Figure 1) 
 
For filling buckets or mop rigs: a short length of open ended garden hose may be attached to the proportioner outlet.  
Replace screen retainer part 100-8 with hose adapter part 100-10.  Use one screen part 100-7 to insure priming. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 151

Page 1: ...s Screw proportioner directly onto garden hose type faucets Remove inlet adapters for mounting onto standard external aerator threads For other faucets see parts break down for adapter part numbers Select a metering tip See section 4 and screw it into the inlet barb Figure 1 Place the chemical container in a convenient location not more than 6 feet below the proportioner greater lifts will reduce ...

Page 2: ...CARE WHEN HANDLING HAZARDOUS CHEMICALS Turn on water and press the blue button to draw in chemical When water is turned off proportioner will reset to dispense clear water FIGURE1 METERINGTIP PUSHBUTTON AIRVENT OUTLETSCREENRETAINER SUPPLYTUBING FOOTVALVE CERAMICWEIGHT CHEMICALCONTAINER INLETADAPTER DETERGENTINLETBARB ...

Page 3: ...atio Oz Gal Ratio Oz Gal Ratio Tan 0 25 512 1 0 20 640 1 0 17 756 1 0 15 853 1 Orange 0 33 384 1 0 30 427 1 0 25 512 1 0 20 640 1 Turquoise 0 50 256 1 0 40 320 1 0 33 384 1 0 25 512 1 Pink 0 63 205 1 0 50 256 1 0 45 284 1 0 33 384 1 Clear 0 75 171 1 0 70 183 1 0 60 213 1 0 45 284 1 Brown 1 00 128 1 0 85 151 1 0 70 183 1 0 50 256 1 Red 1 25 102 1 1 00 128 1 0 80 160 1 0 60 213 1 White 1 50 85 1 1 2...

Page 4: ...drawing RETURNS NO MERCAHNDISE MAY BE RETURNED FOR CREDIT WITH DEMA S WRITTEN PERMISSION RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN ADVANCE OF RETURN WARRANTY DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture This limited warranty does not apply to any products which have a normal like shorter than...

Page 5: ...r w Washer 11 100 12 ID x 8 Lg Supply Tubing 12 61 107 2 Ceramic Weight NO PART NO DESCRIPTION 13 100 16E Foot Valve 14 100 51 Repair Kit NO PART NO DESCRIPTION 15 150 23 Outside Chicago Thread Adapter 16 150 21 Inside Aerator Thread Adapter 17 150 32 Inside Kohler Thread Adapter 18 150 9 2 Irregular Faucet Adapter 19 100 14M Coupling For ID x 8 Lg Tubing 20 34 22 Backflow Preventer INTERNAL AERAT...