OPERATING AND TESTING CO ALARM
When the battery is installed, Green LED will flash once indicating the alarm
is powered and wait for about 1 minute to stabilize the sensor before testing the
unit. To test the unit, press and hold the button until the repeating series of 4
beeps sound with Red LED flashes. When the button is released, the siren will
stop.
Check and test the CO alarm after installation. Ensure that you can clearly hear
the CO alarm in sleeping area. It should be tested weekly and check after re-
occupation following a holiday.
Check that Green LED flashes about every minute to ensure the unit is in
operating mode.
If the Green LED is not flashing once per minute, or the unit does not respond
to the test button:
Make sure the unit contains the recommended type of battery
1.
Ensure the battery is installed correctly.
2.
Make sure the unit has been cleaned adequately.
3.
Check for obvious damage.
4.
If the alarm still fails to work, it must be replaced immediately. Do not attempt
to repair it yourself, warranty will be void.
Note: The test push button is independent function with hush button. During
the normal testing mode, the silence feature will not active.
ADDITIONAL FEATURES
The CO alarm comes with the following friendly additional features for use.
Silence feature
- This feature can be used to silence nuisance alarms. Press
test/silence button during alarm condition will silence the alarm signal for 4
minutes. If the CO surrounding level reaches 200 ppm, the alarm will reacti-
vate. Observe that the Red LED repeatedly series 4 flashes during hush model
last for 4 minutes. The unit will automatically return to normal mode after 4
minutes. If the concentration is increased, the silencer (hush) feature is by pass
and the unit will alarm.
CAUTION : If the CO concentration at 200 ppm the silence feature does not
activate. The user must be aware that if the alarms continually after push the
silence button, the CO concentration surrounding the alarm could be 200 ppm
or greater. Always determine why the alarm has been trigged before using the
silence feature. If the case of alarm is not clear, assure that there is an actual
CO leakage and evacuate the area.