background image

1

DOC PN 392-0210-Rev B 

IMPORTANT SAFETY INSTRUCTIONS 

SAVE THESE INSTRUCTIONS:

This manual contains 

important safety and operating instructions for the Battery Tender® 
Solar Charger and Solar Panels. 

CAREFULLY READ THESE 

INSTRUCTIONS BEFORE USING THE BATTERY CHARGER. 

WARNING AND CAUTION LABEL DEFINITIONS: 

WARNING     

WARNING indicates a potentially hazardous situation, which, if 
not avoided, could result in serious injury or death.

CAUTION     

CAUTION indicates a potentially hazardous situation, which, if 
not avoided, may result in minor or moderate injury.

CAUTION     

CAUTION used without the safety alert symbol indicates a 
potentially hazardous situation that if not avoided, may result in 
property damage. 

GENERAL PRECAUTIONS 

WARNING     

Battery posts, terminals and related accessories contain lead 
and lead components, and other chemicals known to the State 
of California to cause cancer and birth defects or other 
reproductive harm.  Always wash your hands after handling 
these devices. 

WARNING     

Do not operate the battery charger with damaged DC input 
cords or DC output cords or accessories - Replace Cords or 
accessories immediately if damaged. 

Battery Tender

£

 Solar Junior 

Battery Charger & Solar Panels

Designed for six cell lead-acid batteries 

from 1.2 – 200Ah

2

CAUTION     

WORKING WITH LEAD ACID BATTERIES AND BATTERY CHARGERS:  

All lead acid batteries have the potential to emit gasses that may combine 
into a combustible or explosive mixture.  In many cases, it is possible that 
lead acid batteries will emit these gasses during normal discharge and 
charging operations.  Because of this potential danger, it is important that 
you follow the precautions recommended by both the battery and battery 
charger manufacturers before using either one. For example, do not 
exceed the recommended maximum recharge rate (charger output current 
limit), or remove cell caps while charging flooded batteries. 

CAUTION     

CHARGER VOLTAGE COMPATIBILITY:  NEVER 

use a battery charger 

unless the battery voltage matches the output voltage rating of the charger. 
For example, do not use a 12-volt charger with a 6-volt battery and vice-
versa.

CHARGER LOCATION:  LOCATE 

the charger as far away from the 

battery as is allowed by the length of the output cable harness.

  NEVER 

set 

the charger above the battery.

  NEVER 

set the charger on a surface 

constructed from combustible material.  

NEVER

place the battery, the 

charger, or any of the electrical connections between them in an area that 
is likely to become wet. 

EXCESSIVE MOISTURE:

  Do not expose the battery charger or any of its 

electrical connections to rain, snow, or extremely high, condensing 
humidity.

CHARGER ATTACHMENTS:  

Do not use attachments that are not 

recommended or sold by the charger manufacturer.  To do otherwise may 
result in the risk of electric shock, fire, or possibly some other unforeseen 
potential personal injury situations. 

HANDLING POWER CORDS:

  When handling electric power cords, 

always pull by the plug rather than by the cord.  This will reduce the risk of 
damage to both the plug and cord, and it will minimize the likelihood of 
electric shock resulting from that damage. 

LOCATION OF POWER CORDS:

  Make sure all electric power cords are 

located so that they cannot be stepped on, tripped over, or otherwise 
subjected to damage or stress. 

MONITORING SEALED & NON-SEALED BATTERIES:

  When leaving a 

battery charger connected to either a sealed (AGM or GEL) or non-sealed 
(flooded battery) for extended periods of time (weeks, months, etc.), 
periodically check the battery to see if it is unusually warm.  This is an 
indication that the battery may have a weak cell and that it could go into a 
thermal runaway condition.  If the battery releases an excessive amount of 
gas or if the battery gets hotter than 130

q

F (55

q

C) during charging, 

disconnect the charger and allow the battery to cool.  Overheating may 
result in plate distortion, internal shorting, drying out or other damage.  For 
flooded batteries, also check individual cell fluid levels against 
manufacturer's recommendations for safe operation. 

Summary of Contents for Battery Tender Solar Junior

Page 1: ...GE COMPATIBILITY NEVER use a battery charger unless the battery voltage matches the output voltage rating of the charger For example do not use a 12 volt charger with a 6 volt battery and vice versa CHARGER LOCATION LOCATE the charger as far away from the battery as is allowed by the length of the output cable harness NEVER set the charger above the battery NEVER set the charger on a surface const...

Page 2: ...kaline and other similar types of batteries If you have any doubt about the type of battery that you have please contact the battery manufacturer before attempting to charge the battery 7 NEVER charge a visibly damaged or frozen battery PREPARING TO CHARGE First follow all General Personal Precautions as previously explained and then continue WARNING IF THE BATTERY MUST BE REMOVED FROM THE VEHICLE...

Page 3: ...arge automotive or marine deep cycle type batteries may take several days to fully recharge 6 WORKING WITH A DEAD BATTERY OR A BATTERY WITH A VERY LOW VOLTAGE If you try to charge a dead battery having a voltage below 3 Volts the BATTERY TENDER charger will not start to charge because an internal safety circuit prevents the battery chargers from generating any DC output voltage NOTE If a 12 Volt L...

Page 4: ...recommendations of major lead acid battery manufacturers Maximum Operating Temperature 50 qC Typical Charger Case Dimensions BT Solar Jr 4 0 in 100 mm L x 2 5 in 63 mm W x 75 in 19 mm H BT Solar Panel Dimensions BT Solar 5W 16 in 406 5mm L x 16 in 406 5mm W x 1 in 25 5mm H BT Solar 10W 16 in 406 5mm L x 29 in 736 5mm W x 1 in 25 5mm H BT Solar 15W 16 in 406 5mm L x 41 in 1041 5mm W x 1 in 25 5mm H...

Reviews: