4.1 Techanical Data Sheet Of Series
4. Technical Characteristics:
3.6 Sw2/sw6 Setting:
Worm Gear
5500N
5000N
3800 RPM
60W
24 Vdc
3A
500kg
6 Meters
5.5A for Maximum 10 secs
-20oC~+50oC
250 X 170 X 265
8 kg
21.9 cm / sec
PL500
Motor
Gear type
Peak thrust
Nominal thrust
Engine RPM
Absorbed Power
Power supply
Nominal input power
Maximum gate weight
Maximum gate length
Maximum operating current
Operating Temperature
Dimension LxWxH mm.
Weight
Speed
Default Device
Description
Remark
ON
OFF
ON
OFF
Ph1
Ph2
Stop
D
C SW6
SW2
1
2
3
4
5
6
SW6
1 – ON
2 – ON
3 – ON
4 – ON
5 – ON
6 – ON
Ph1
Photocell-1
Ph2
Photocell-2
Stop
Remote
Remote
None
Switch to ON if Ph1 is not connected; Otherwise,
switch to OFF if Ph1 is connected
Switch to ON if Ph2 is not connected; Otherwise,
switch to OFF if Ph2 is connected
Switch to ON if “Stop (12)” is not connected; Otherwise,
switch to OFF if “Stop” is connected to any device
Setting with SW2
Setting with SW2
No function
1 & 2 must switch to ON
,
if Ph1 & Ph2 are not
connected to any devices
Default Device
Description (coordinate with remote)
Remark
SW2
SW2
ON
OFF
2/4 Channel
Transmitter
2/4 Channel
Transmitter
ON, Button B is pedestrian mode
If connected with external device (EXT+/EXT-; 1/2)
,
SW6 4-ON; Button C on the remote can operation the device
If connected with external device (EXT+/EXT-; 1/2)
,
SW6 5-ON; Button D on the remote can operation the device
OFF
,
Button B can operation the external device
(EXT+/EXT-; 1/2)
OFF
,
SW6 4-ON; Button C is pedestrian mode;
Button D no function
OFF
,
SW6 5-ON; Button D is pedestrian mode;
Button C no function
With external device:
SW6 4 - ON/OFF >
Button C - ON/OFF;
SW6 5 - ON/OFF >
Button D - ON/OFF;
If using a 2-channel
remote and require the
Button B to operation
the external device
,
switch the SW2 to OFF
10
INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL