Height of skimmer compartment
between 180 -290mm
Starting the skimmer
-
position the skimmer in the sump
-
feed water into the skimmer compartment (if applicable)
-
open the water level adjuster (diagram c) fully by turning it anti-clockwise
-
start the skimmer pump
-
close the water level adjuster until fine bubbles are visible between the bayonet and
the bottom of the skimmer cup (diagram d)
-
initially keep the foam level in the skimmer cup low to avoid over skimming and
possible flooding of the cup
-
wait a minimum of 24 hours before the final adjustment
-
turn the water level adjuster in or out until the fine air bubbles start bursting
approximately half way up the cups riser tube
-
for dry foam turn the water level adjuster anti-clockwise
-
for wet foam clockwise
-
Important:
Never allow the pump to run dry.
Operation with Ozone
The Skimmer can be operated with ozone up to max. 50 mg/h per pump. One air
connection of the ozoniser should be connected via a suitable silicon hose to the protein
skimmer pump. The air is automatically sucked in the ozoniser by the skimmer pump.
Should the skimmer performance deteriorate please check the ozoniser for blockage.