Deltec E-

Flow 

pumps are brushless motor, true sine wave 24V DC pumps.  

They come with a separate controller. The power consumption and performance can 
be  selected  with  the  up/down  buttons  located  on  the  face  of  the  controller.  The 

pump  itself  can  be  installed  either  dry  outside  the  sump  or  submersed  inside  the 
sump or aquarium. 

The controller is not submersible

.   

 
 

Important safety instructions 

 

Deltec E-Elow

24V

 pumps are designed /manufactured according to existing technical 

standards and safety regulations. However there is a potential risk to persons and 
goods if the pumps or safety instructions are not being observed. Persons under the 
age of 16 or persons who are unable to understand possible risks or do not fully 

understand the safety and operating instructions are not allowed to use this pump 
for safety reasons.  

Keep these instructions in a safe place where it is accessible at all times. 

 

Please read the following instructions very carefully before installing the 

pump. Should you still have questions please contact your supplier.  

 

Installation of the pump 

 

Always unplug the pump during the installation process. 

 

- After unpacking check pump, controller and cables for any damage. If any 
components show signs of damage, do not use the pump.  
- The pumps are designed for ‘dry’ or submersible installation in fresh or seawater 
aquarium systems.  
- The pumps are 

not 

self priming and need to be installed below the water level.  

- The separate controller must be placed in a dry, cool area, to prevent damage to 
the electronic control circuits through water or dampness.  
- To install, place the pump on a firm, even surface.  
- Never select pipes or hoses smaller in diameter than that of the pumps suction 
and pressure side fittings. Shut off valves should be selected one size bigger and 
fitted with reducers down to the normal pipe diameters, since the normal inner shut 
off valve diameter restricts the flow considerably.  
- To achieve best performance, plan the piping as short as possible, use slow bends 

instead of elbows.  
- On longer pipe installation increase the diameter of the pipes. Instead of 32 mm 
use 40 mm, etc.  
- It is good practice to use a straight length of pipe of app 300 mm on the suction 

side of the pump. This will give a laminar flow into the pump and prevent unwanted 
noises  
- Never run the pump dry, this may lead to irreparable damage.  
 

 