DeltaTRAK ThermoTrace 15053 User Manual Download Page 4

2

Status Descriptions

Display Descriptions

• 

Standby Mode: 

The backlight is off and the last temperature reading is displayed. 

(Figure 1)

• 

Battery Symbol: 

The “empty” battery symbol flashes when the battery is depleted. 

(Figure 2)   

1. 

Modes: Body Temperature; Surface Temperature; Count Mode 

2. 

Device Status: System; USB Connection; Volume; Power 

3. 

Measurement Result: Temperature Reading 

4. 

Temperature Scale: Celsius; Fahrenheit 

5. 

Function or Memory: M - - indicates the current SAVED reading;     
F - - indicates the 

FUNCTION 

number 

6. 

History Temp (Saved Temperature Reading) or Environmental Temp 
(Ambient Temperature) 

7. 

Environmental Temperature Reading 

• 

Normal Temperature: 

When the temperature reading is normal green lights flash 

on both sides, and the voice command, “Normal temperature,” will sound. (Figure 3)

• 

Abnormal Temperature:

 When the temperature reading is abnormal red lights 

flash on both sides and the display backlight turns red. (Figure 4)

Fig. 1

Fig. 2

97.7

°

F

Body Mode

Environment Temp

M

0 1

68.0

97.7

°

F

Body Mode

Environment Temp

M

0 1

68.0

97.7

°

F

Body Mode

M

0 1

68.0

Environment Temp

Fig. 3

Body Mode

Environment Temp 

64.0

°F

97.7

97.7

°

F

Body Mode

Envrironment Temp

M

03

68.0

Fig. 4

Body Mode

Environment Temp 

64.0

°F

97.7

°

F

Body Mode

Envrironment Temp

M

03

68.0

Summary of Contents for ThermoTrace 15053

Page 1: ...User Guide Auto Check Non Contact Infrared Forehead Thermometer K3 Pro Model 15053 Please read this manual before operating unit Important safety information inside...

Page 2: ...ps www deltatrak com 15053 2 Support and Technical Services https www deltatrak com support tech support 3 Warranty https www deltatrak com support warranty 5 Introduction Video https www deltatrak co...

Page 3: ...ting Hole 11 Battery Cover Accuracy 0 2 degrees 93 F 113 F 34 C 45 C Alarm Mode Flashing Red LED audible tone for 10 seconds Measuring Distance 2in 6in 5cm 15cm Display LCD Transmission Interface USB...

Page 4: ...Saved Temperature Reading or Environmental Temp Ambient Temperature 7 Environmental Temperature Reading Normal Temperature When the temperature reading is normal green lights flash on both sides and t...

Page 5: ...y History Temp and Environmental Temp The saved temperature log number i e M01 will also be displayed Press the left arrow to scroll through the saved readings in the order that the measurements were...

Page 6: ...ome louder Figure 12 To mute the volume press the left arrow until the speaker symbol no longer appears Figure 13 To save the setting press the SET button until the HOME SCREEN is displayed 7 Setting...

Page 7: ...nnection Use Type C USB cable to connect to your computer Download the software and connect the device in order to store measurement results in real time For more online instructions please refer to t...

Page 8: ...The subfolder TempData year month is automatically generated within the TestACY folder The format is Year Month Day The file type is TXT If you cannot find the folder use your computer s search functi...

Page 9: ...Temp 99 5 Bod Save As 97 5F Normal COM V1 03 Serial Port Operation Disconnect COM1 Quantity 1 15 12 30 97 5F 74 3F 1 15 12 32 97 7F 74 3F Test Time Test Value Environment TESTACY E success Jul 6 2020...

Page 10: ...e data click Save as Name the file and select the file type txt or csv Set the upper limit of the alarm When the temperature reading exceeds this value the thermometer will give an audible alarm Quant...

Page 11: ...The ThermoTrace Auto Check Pro Non Contact Infrared Forehead Thermometer was designed for long term professional use and has a limited warranty period of 1 year from the date of purchase against defec...

Page 12: ...64 8923 2778 www deltatrakchina com cn DTI China Limited NT Hong Kong 852 3568 5538 www dtiap com DTI Asia Pacific Auckland New Zealand 64 9 5757 886 www deltatraksouthpacific com DTI South Pacific Os...

Reviews: