![DeltaTRAK ThermoTrace 15039 Quick Start Manual Download Page 5](http://html1.mh-extra.com/html/deltatrak/thermotrace-15039/thermotrace-15039_quick-start-manual_2479174005.webp)
5
Thermocouple Probe Function Modes
Swing out the Thermocouple probe until it is fully extended
and locked into position. Insert the probe in the area to be
measured, press the
PROBE
button to continuously display
the probe temperature readings for up to 4 minutes. The
device will automatically shut off after 4 minutes to extend
the battery life.
Press and hold the
PROBE
button to interrupt the scanning
and hold the last temperature reading.
HOLD
will be dis-
played on the screen (if you release the
PROBE
button, the
unit will hold the reading then shut off in ~15 seconds).
To continue measuring temperature, press the
PROBE
button
again to display the current probe reading.
WARNINGS
Do not twist the probe, over-extend, or rotate the probe in
the wrong direction.
Stress on probe may cause it to break.
After measuring high temperature, the probe will be HOT.
Probe is dangerous when in an open position. Remember to
fold the probe back when not in use.
The thermocouple probe may be damaged if the temperature
exceeds the probe measurement range.
To avoid electric shock and thermometer damage, do not measure any live
circuit where voltage exceeds 24V AC RMS or 60V DC with the thermocouple
probe.
HACCP Food Safety Zone Functions
The
HACCP CHECK
feature is incorporated in the LED backlight to indicate when
a food product is in the HACCP safe zone or in the temperature danger zone.
The Green LED backlight
Indicates a safe cool or frozen condition below 40ºF (4°C)
or indicates a safe hot holding temperature above 140ºF (60°C).
The Red LED backlight
Indicates the temperature is in the HACCP danger zone
between 40ºF to140°F (4°C to 60°C).