DeltaTRAK ThermoTrace 15039 Quick Start Manual Download Page 5

5

Thermocouple Probe Function Modes

Swing out the Thermocouple probe until it is fully extended 
and locked into position.  Insert the probe in the area to be 
measured, press the 

PROBE

 button to continuously display 

the probe temperature readings for up to 4 minutes. The 
device will automatically shut off after 4 minutes to extend 
the battery life. 

Press and hold the 

PROBE

 button to interrupt the scanning 

and hold the last temperature reading. 

HOLD

 will be dis-

played on the screen (if you release the 

PROBE

 button, the 

unit will hold the reading then shut off in ~15 seconds).

To continue measuring temperature, press the 

PROBE

 button 

again to display the current probe reading.

WARNINGS

Œ

 Do not twist the probe, over-extend, or rotate the probe in 

the wrong direction.



 Stress on probe may cause it to break.

Ž

 After measuring high temperature, the probe will be HOT.



 Probe is dangerous when in an open position. Remember to 

fold the probe back when not in use.

 The thermocouple probe may be damaged if the temperature 

exceeds the probe measurement range.

 

To avoid electric shock and thermometer damage, do not measure any live 

circuit where voltage exceeds 24V AC RMS or 60V DC with the thermocouple 

probe.

HACCP Food Safety Zone Functions

The 

HACCP CHECK

 feature is incorporated in the LED backlight to indicate when 

a food product is in the HACCP safe zone or in the temperature danger zone.

The Green LED backlight

 

Indicates a safe cool or frozen condition below 40ºF (4°C) 
or indicates a safe hot holding temperature above 140ºF (60°C).

The Red LED backlight

 

Indicates the temperature is in the HACCP danger zone 
between 40ºF to140°F (4°C to 60°C).

Summary of Contents for ThermoTrace 15039

Page 1: ...Model 15039 15039 01 Quick Start Guide Infrared Thermocouple Probe Combo BLE...

Page 2: ...odes The Infrared Thermocouple Probe Combo Thermometer is a non contact infrared thermometer combined with a thermocouple probe featuring a color coded backlight that lets you know when temperature is...

Page 3: ...le While scanning the newest temperature will be updated on the LCD and the measurement will continue as long as the SCAN button is depressed When the SCAN button is released HOLD will appear on the d...

Page 4: ...n the screen Press SCAN once to enter lock mode LOCK will freeze on the screen The thermometer will continuously display the temperature for up to 60 minutes or until the SCAN button is pressed and LO...

Page 5: ...nd or rotate the probe in the wrong direction Stress on probe may cause it to break After measuring high temperature the probe will be HOT Probe is dangerous when in an open position Remember to fold...

Page 6: ...displayed when the temperature being measured is outside of the measurement range Er2 is displayed when the thermometer is exposed to rapid changes in the ambient temperature Er3 is displayed when th...

Page 7: ...After powering on press the BLE key to start the Bluetooth broadcast Each broadcast time is 30 seconds During the broadcast if the APP is not successfully paired with the thermometer the device will...

Page 8: ...2741 2837 2664 8923 2778 www deltatrakchina com cn DTI China Limited NT Hong Kong 852 3568 5538 www dtiap com DTI Asia Pacific Auckland New Zealand 64 9 5757 886 www deltatraksouthpacific com DTI Sout...

Reviews: