29
GB
Troubleshooting
Problem
Possible cause
Remedy
Motor will not start
No mains power supply
Check the socket, cable, lead and
plug for damage, and if necessary,
have any damage repaired by qualified
repair personnel.
Overload protection trip-
ped
Wait until the motor has cooled down,
then press the Reset button and re-
start the unit
Lid of housing not closed
properly
Tightly screw in the housing interlock
Garden waste is not
drawn in
Shredding material is too
soft
Use the pusher or add dry twigs/
branches
Unit blocked
See section „Removing blockages“
Shredding material in
discharge duct
Remove shredding material from
discharge duct
Unit won‘t shred
properly
Blades are blunt
Check and turn, sharpen or replace
blades as necessary (see section
„Sharpening, turning, replacing the
blades“)
Summary of Contents for DG-EKS 2445