INSTALLATION AND OPERATING INSTRUCTIONS

 

FAN / LED LIGHT / LED NIGHT LIGHT 

READ AND SAVE THESE INSTRUCTIONS

   

 

GENERAL SAFETY INFORMATION       

1.

 

Make sure that the electric service supply voltage is AC 
120V, 60Hz. 

2.

 

Follow all local electrical and safety codes, as well as the 
Nation Electrical Code (NEC) and the Occupation Safety 
and Healthy Act (OSHA). 

3.

 

Always disconnect the power source before working on or 
near the ventilating fan, motor or junction box. 

4.

 

Protect the power cord from sharp edges, oil, grease, hot 
surfaces, chemicals or other objects. 

5.

 

Do not kink the power cord. 

6.

 

Do not install the unit where ducts are configured as shown 
in Fig. A. 

7.

 

Provide suction parts with proper ventilation. 

8.

 

This unit is UL listed for use over a bathtub or shower 
when installed in a GFCI protected branch circuit. 

9.

 

These ventilating fans are intended for residential usage 
only.  

10.

 

Do not install this ventilating fan where air temperature 
may exceed 40°C (104°F). 

 
 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

Fig. A 

 

WARNING                        

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING: 
 
1.

 

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer. 

2.

 

Before servicing or cleaning unit, switch power off at 
service panel and lock the service disconnecting means to 
prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, to the 
service panel. 

3.

 

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction. 

4.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent back drafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society 
of Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE) and local code authorities. 

5.

 

When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities. 

6.

 

Ducted ventilating fan must always be vented to the 
outdoors. 

7.

 

If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application and be connected 
to a GFCI (Ground Fault Circuit Interrupter) – protected 
branch circuit.   

8.

 

Do not use this unit with any other solid-state control 
device. Solid-state controls may cause harmonic distortion, 
which can cause motor humming noise. 

9.

 

NEVER place a switch where it can be reached from a tub 
or shower. 

10.

 

Not to be installed in a ceiling thermally insulated to a 
value greater than R40. (This is required for installation in 
Canada only) 

11.

 

Do not open/disassemble the LED light engine or tear off 
the warranty label for protect the life and performance. 

 

 

CAUTION 

1.

 

To

 

reduce the risk of electric shock, please disconnect the 

electrical supply circuit to the fan before installing

 

light kit. 

2.

 

For general ventilating use only. Do not use to exhaust 
hazardous or explosive materials and vapors. 

3.

 

Not for use in cooking area. (Fig. B)

 

4.

 

This product must be properly connect to the grounding 
conductor of the supply circuit.

 

 

Cooking area

 

Fig. B 

Summary of Contents for VFB080D4LED1

Page 1: ...and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the ...

Page 2: ...on bracket Suspension bracket No 12 0 inch Refer to Fig B 01 B 02 I II 16 0 inch Refer to Fig B 03 B 04 I II III 19 2 inch Refer to Fig B 03 B 04 I II III 24 0 inch Refer to Fig B 03 B 04 I II III 1 1 TypeⅠ 12 inches between joists 1 1 1 Insert the suspension bracketⅠ into the bracket cover of adaptor side and select one of suspension bracketⅡ of the back of the fan body 1 1 2 Insert the fan betwe...

Page 3: ... Install the duct with a gradient 1 2 to the outside 3 Connect wiring 3 1 Follow all local electrical and safety codes 3 2 NEVER place a switch where it can be reached from a tub or shower 3 3 Connect wires as shown in wiring diagrams 3 4 Using wire nuts connect house power cable to ventilating fan light and night light wires 3 5 14 AWG 2 1 mm2 is the smallest conductor that shall be used for bran...

Page 4: ... Exclusions 1 During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made throu...

Reviews: