MODELS 

SIG80 / SIG80M / SIG110 / SIG110H / SIG110D 

Page 1. 

INSTALLATION   AND OPERATING INSTRUCTIONS

 

VENTILATION FAN

 

READ AND SAVE THESE INSTRUCTIONS

 

GENERAL SAFETY INFORMATION

 

1.

 

Make sure that the electric service supply voltage is AC 120V, 60Hz.  

2.

 

Follow all local electrical and safety codes, as well as the National 
Electrical Code (NEC) and the Occupational Safety and Health Act (OSH 
Act). 

3.

 

Always disconnect the power source before working on or near the 
ventilating fan, motor or junction box.  

4.

 

Protect the power cord from sharp edges, oil, grease, hot surfaces, 
chemicals or other objects.  

5.

 

Do not kink the power cord.  

6.

 

Do not install the unit where ducts are configured as shown in Fig. A.  

7.

 

Provide suction parts with proper ventilation.  

8.

 

This unit is UL listed for use over a bathtub or shower when installed 
in a GFCI protected  branch circuit.  

9.

 

These ventilating fans are intended for residential usage only.  

 

WARNING

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 
TO PERSONS, OBSERVE THE FOLLOWING:

 

1.

 

Use this unit only in the manner intended by the manufacturer. If you 
have questions, contact the manufacturer.  

2.

 

Before servicing or cleaning the unit, switch the power off at the 
service panel and lock the service disconnecting means to prevent the 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel.  

3.

 

Installation work and electrical wiring must be done by a qualified 
person(s) in accordance with all applicable codes and standards, 
including fire -rated construction.  

4.

 

Sufficient air is needed for proper combustion and exhausting of 
gases through the flue (chimney) of fuel burning equipment to 

guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society 
for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) 
and local code authorities.  

5.

 

When cutting or drilling into the wall or ceiling, do not damage 
electrical wiring and  other hidden utilities.  

6.

 

Ducted ventilating fans must always be vented to the outdoors.  

7.

 

If this unit is to be installed over a tub or shower, it must be marked as 
appropriate for the application and be connected to a GFCI (Ground 
Fault Circuit Interrupter)  -protected branch circuit.  

8.

 

Do not use this unit with any other solid - state control device. 
Solid-state controls may cause harmonic distortion, which can cause a 
motor humming noise.  

9.

 

NEVER place a switch where it can be reached from a tub or shower.  
 
 
 

 
 
 
 
 
 
 

 

10.

 

Not to be installed in a ceiling thermally insulated to a value greater 
than R40. (This is required for installation in Canada only).

 

 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

Fig. A 

 

CAUTION

 

1.

 

For general ventilating use only. Do not use to exhaust hazardous or 
explosive materials and vapors.  

2.

 

Not for use in cooking areas. (Fig. B)  

3.

 

This product must properly connect to the grounding conductor of 
the supply circuit.  

4.

 

To reduce the risk of injury to persons, install the fan at least 7 feet 
(2.1m) above the floor.  

 

45°

Cooking area

45°

Do not install above or

  inside this area

 Cooking

Equipment

floor

 

Fig. B 

 

prevent backdrafting. Follow the heating equipment manufacturer’s