POWER CONNECTIONS

A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
motor to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the
same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the motor.

WARNING: DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

MOTOR SPECIFICATIONS

Your machine is wired for 120 volt, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position. 

GROUNDING INSTRUCTIONS

WARNING: THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Fig. A

Fig. B

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for use
on a supply circuit having a nominal rating less than 150
volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A, the
machine will have a grounding plug that looks like the plug
illustrated in Fig. A. A temporary adapter, which looks like
the adapter illustrated in Fig. B, may be used to connect
this plug to a matching 2-conductor receptacle as shown
in Fig. B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

WARNING: IN ALL CASES, MAKE CERTAIN THE 

RECEPTACLE IN QUESTION IS PROPERLY

G R O U N D E D . I F Y O U A R E N O T S U R E H AV E A
QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g r o u n d i n g i n s t r u c t i o n s a r e n o t c o m p l e t e l y
understood, or if in doubt as to whether the machine is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-conductor
receptacles that accept the machine’s plug, as shown in
Fig. A.

Repair or replace damaged or worn cord immediately.

Summary of Contents for SHOPMASTER GR250

Page 1: ...R250 PART NO 905595 05 03 02 Copyright 2002 Delta Machinery ESPA OL P GINA 13 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assist...

Page 2: ...y to get caught in moving parts Nonslip footwear is recommended Wear protective hair covering to contain long hair 12 SECURE WORK Use clamps or a vise to hold work when practical It s safer than using...

Page 3: ...nding wheel 15 NEVER GRIND NEAR FLAMMABLE GAS OR LIQUIDS Sparks can create a fire or an explosion 16 AVOID AWKWARD OPERATIONS AND HAND POSITIONS where a sudden slip could cause a hand to move into the...

Page 4: ...pter should be used only until a properly grounded outlet can be installed by a qualified electrician The green colored rigid ear lug and the like extending from the adapter must be connected to a per...

Page 5: ...ing container s Remove the protective coating from all unpainted surfaces This coating may be removed with a soft cloth moistened with kerosene do not use acetone gasoline or lacquer thinner for this...

Page 6: ...5 16 18x3 4 knob 2 6 Eye shield knob 2 7 Eye shield spacer 2 8 5 16 flat washer 6 9 1 4 flat washer 4 10 Eye shield 2 11 Left tool rest 12 Left tool rest arm 13 Left spark guard 14 Right spark guard...

Page 7: ...ece that is being ground Always maintain a distance of 1 8 or less between the grinding wheel and the inside edge of the tool rest As the wheels wear down the tool rest should be adjusted accordingly...

Page 8: ...TENERS NOT SUPPLIED THROUGH THE TWO HOLES A Fig 9 IN THE GRINDER BASE Fig 9 Fig 7 A Fig 8 A B C D E F A A OPERATING CONTROLS AND ADJUSTMENTS STARTING AND STOPPING GRINDER The switch A Fig 10 is locate...

Page 9: ...point on the face of the wheel and dress the wheel by moving the dresser back and forth Repeat this operation until the face of the grinding wheel is clean and the corners of the wheels are square GR...

Page 10: ...loosen counterclockwise to tighten the arbor nut 4 To replace the grinding wheel on the right turn the arbor nut counterclockwise to loosen clockwise to tighten the arbor nut 5 The arbor bushing shou...

Page 11: ...11 NOTES...

Page 12: ...lta s sole warranty and sets forth the customer s exclusive remedy with respect to defective products all other warranties express or implied whether of merchantability fitness for purpose or otherwis...