background image

 

 

              Instruction Manual 

 

 

 

   

 

                                                                                                          PMC-24V100W1AA 

 

1.   Safety Instructions

 

 

 

To ensure sufficient convection cooling, always maintain a safety   
distance of >20mm from all ventilated surfaces while the device is 
in operation. 

 

The device is not recommended to be placed on low thermal        
conductive surface, for example, plastics. 

 

Note that the enclosure of the device can become very hot 
depending on the ambient temperature and load of the power 
supply. 
Do not touch the device while it is in operation or immediately after 
power is turned OFF. Risk of burning! 

 

Do not touch the terminals while power is being supplied. Risk of     
electric shock. 

 

Prevent any foreign metal, particles or conductors to enter the 
device through the openings during installation. It can cause: 

     - Electric shock; Safety Hazard; Fire; Product failure 

 

Warning: When connecting the device, secure Earth connection 
before connecting L and N. When disconnecting the device, remove 
L and N connections before removing the Earth connection. 

 

2.   Device Descriptions 

 

 

            Refer to Fig. 1: 

1     Input & Output terminal block connector 

2     DC voltage adjustment potentiometer 

3     DC OK control LED (green) 

 
 
 
 
 
 
  
 
 
 
 
 
 

 
 
 
 

 
3.    Installation of the Device 

     

 

           Refer to Fig. 2: 

     

A   Mounting holes for power supply assembly onto the mounting surface. Power  

supply shall be mounted on minimum 2 mounting holes using M3 screw,  
minimum 5mm length.  

 

     

B    This surface belongs to customer’s end system or panel where the power 

           

        supply is mounted. 

 

     C

 

  Connector 

 

 

        

 

 

 

 

 

   Use flexible cable (stranded or solid), AWG no. 22-12. The torque at the 

Connector shall not exceed 13Kgf.cm The insulation stripping length should 
not exceed 0.275” or 7mm

 

 

 
 
 
 

 

 

    4.    Installation of Mounting Accessories

 

     Only use M3 screw < 6mm through the base mounting holes. This is to keep 

           a safety distance between the screw

 

and internal components.  

 

Refer to Fig. 4:  

       Recommended mounting tightening torque: 4 ~ 8Kgf.cm 

 
 
 
 
 
 

   

     

Fig. 4 Mounting Screw 

Fig. 2  Mounting Orientation

 

www.delta.com.tw/industrialautomation

 

Side Mounting (Vertical)  Base Mounting (Vertical)   Side Mounting (Horizontal) 

Fig. 3 Wire Type 

Lug 

Stripped wire

Fig. 1  Device Descriptions 

Base surface 

Top 

Side surface 

Ventilated surface 