background image

104437   Rev. A

Installation

Cartridge Installation

3

  

 

 

A.

B.

Turn off water supplies. Remove cover (1),

bonnet nuts (2) and test caps (3) from the 

rough-in body (4).

Place a bucket or small container over the front

of the valve body and slowly open the water

supplies to flush any debris from the supply

lines before installing the cartridge. Turn the

water supplies back off.

Rotate valve cartridge (1) so the words “HOT 

COLD” (2) appear on the top. Insert cartridge 

assembly into rough-in body. Make sure the key 

(3) on the cartridge is fully engaged with the slot 

in the brass body (4). Insert bonnet nut (5) on  

the cartridge and thread onto the body. Hand 

tighten securely. Slide o-ring (6) over cartridge 

and bonnet.A light coating of plumbers grease 

applied to o-rings may aid in assembly.

For the exceptions of back to back or reverse

installations (hot on right and cold on left) only:

Rotate valve cartridge (1) so “HOT COLD” (2) 

appears on the bottom.

Apply silicone lube to the three o-rings shown 

above to make the cartridge easier to install and 

remove from the rough-in body.

Install the cartridge making sure that the keys 

are fully engaged with the slot in the rough-in 

body (see step B).

Slide o-ring (4) and bonnet nut (3) over the 

cartridge and thread onto the rough-in body. 

Hand tighten securely.

Back to back Installation

Normal Installation  

(changes not required)

Reverse

Installation

Cold

Hot

1

2

3

4

2

3

1

2

3

4

5

3

4

2

4

3

1

1

6

Summary of Contents for MultiChoice T24 Series

Page 1: ... how to properly make these adjustments please refer to page 5 and if still uncertain call us at 1 800 345 DELTA After installation and adjustment you must affix your name company name and the date you adjusted the Rotational Limit Stop to the caution label provided and apply or attach the label to the back side of the closest cabinet door and the warning label to the water heater Leave this Instr...

Page 2: ...ervice Technical Service Centre 55 E 111th Street 350 South Edgeware Road Indianapolis IN 46280 St Thomas Ontario Canada N5P 4L1 Attention Customer Solutions Attention Customer Service www deltafaucet com service parts contact us http www deltafaucet ca customersupport assistance html Proof of purchase original sales receipt from the original purchaser must be made available to Delta Faucet Compan...

Page 3: ...nd thread onto the body Hand tighten securely Slide o ring 6 over cartridge and bonnet A light coating of plumbers grease applied to o rings may aid in assembly For the exceptions of back to back or reverse installations hot on right and cold on left only Rotate valve cartridge 1 so HOT COLD 2 appears on the bottom Apply silicone lube to the three o rings shown above to make the cartridge easier t...

Page 4: ...cone lube to the o ring 2 to make the diverter sleeve 3 easier to install diverter cartridge A light coating of plumbers grease applied to o rings 4 may aid in assembly Install diverter cartridge 1 assuring that the locating pin on the bottom of the cartridge aligns with mating hole in rough in body Slide diverter sleeve 3 over cartridge stem aligning tabs on the diverter sleeve with slots in roug...

Page 5: ... seasonally if the inlet water temperature changes For example during the winter the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures A water temperature for a comfortable bath or shower is typically between 90 F 110 F Run the water so that the cold water is as cold as it will get and hot water is as hot as it will get Place the handle...

Page 6: ...ded onto diverter sleeve Note For thick wall installations order installation kit RP90542 to support finished wall thickness up to 2 1 8 On rough or uneven surfaces it is necessary to apply caulk around the backplate 1 to supplement the seal Do not caulk the drip notch in the bottom of the backplate 1 Do not caulk the escutcheon 4 1 2 A B 1 2 5 4 3 3 Valve Handle Installation Using an allen wrench...

Page 7: ...ortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salida 1 Sortie 1 Outlet 2 Salida 2 Sortie 2 Outlet 3 Salida 3 Sortie 3 Outlet 1 Salid...

Page 8: ...valve to make sure COLD WATER FLOWS FIRST 2 To remove valve cartridge from body shut off water supplies and remove handle and bonnet nut Do not pry the valve cartridge out of the body with a screwdriver Place handle on stem and rotate counterclockwise approximately 1 4 turn after the stop has been contacted Lift valve cartridge out of body 3 To remove seats and springs Remove valve cartridge Separ...

Reviews: