Basic Inspection
Item
Content
General Inspection
Periodically inspect the screws of the connection between the HMI and device.
Tighten screws as necessary as they may loosen due to vibration and varying
temperatures.
Ensure that oil, water, metallic particles or any foreign objects do not fall inside
the HMI, control panel or ventilation slots and holes. As these will cause damage.
Ensure the correct installation and the control panel. It should be free from
airborne dust, harmful gases or liquids.
Inspection before
operation (power is not
applied)
Ensure that all wiring terminals are correctly insulated.
Ensure that all wiring is correct or damage and or malfunction may result.
Visually check to ensure that there are not any unused screws, metal strips, any
conductive or inflammable materials inside HMI.
Ensure to lower electromagnetic interference when devices are influenced by it.
Ensure that the external applied voltage to HMI is correct and matched to the
controller.
Inspection before
operation (power is
applied)
Check if power LED lights.
Check if the communication among devices is normal.
Please contact our local distributors or Delta sales representative if there are any
abnormal conditions.
(8)
Pin Definition of Serial Communication
COM1 Port
(
Supports Flow Control
)
COM Port
PIN
Contact
RS-232
1
2
RXD
3 TXD
4
5 GND
6
7 RTS
8
CTS
9
Note: Blank = No Connection.
COM2 Port
(
Supports Flow Control
)
COM Port
PIN
MODE1
MODE2
MODE3
RS-232
RS-422
RS-485
1 TXD+ D+
2
RXD
3 TXD
4
RXD+
5
GND GND GND
6
TXD-
D-
7 RTS
8
CTS
9 RXD-
Note1: Blank = No Connection.
Note2: When COM2 port is used for RS-232 flow control, i.e. RTS and CTS signals are used for flow control,
COM3 port will become incapable of being used.
Note3: When COM2 port is used for RS-422 flow control, please refer to the following COM3 Port signals table for
pin assignments. The signals, RTS+, CTS+, RTS- and CTS- shown in brackets are the signals used for
flow control.
COM3 Port
COM Port
PIN
MODE1
MODE2
MODE3
RS-232
RS-422
RS-485
1
TXD+(RTS+)
D+
2
RXD
3 TXD
4
RXD+(CTS+)
5
GND GND GND
6
TXD-(RTS-)
D-
7
8
9 RXD-(CTS-)
Note1: Blank = No Connection.
Note2: When COM2 port is used for RS-422 flow control, please refer to the COM3 Port signals table above for pin
assignments. The signals, RTS+, CTS+, RTS- and CTS- shown in brackets are the signals used for flow control.
Ethernet Interface (LAN)
Ethernet Interface (LAN)
PIN
Contact
Ethernet
1 TX+
2
TX-
3 RX+
4
5
6
RX-
7
8
Note: Blank = No Connection.
DMCNET
Ethernet Interface(LAN)
PIN
MODE
1 D1+
2
D1-
3 D2+
4
5
6
D2-
7
8
Note: Blank = No Connection.
Remote Module
Ethernet Interface (LAN)
PIN
Contact
1
2
3
4
TX+
5 TX-
6
7 RX+
8
RX-
Note: Blank = No Connection.
(9) Dimensions
HMC08-N500S52
T=1.6mm(0.06") ~
5.0mm(0.19")
(2.06")
174.
1(
6.
85")
227.1(8.94")
0
+0.04"
(8.63" )
0
219.4
+1
+0
.04"
6.
55"
0
+1
166.
5
0
NOTE:
4-
R1
.0
(0
.0
4"
)
52.3
T
(10) Specifications
MODEL
HMC08-N500S52
LCD MO
DULE
Display Type
8” TFT LCD (65536
colors
)
Resolution
800 x 600 pixels
Backlight
LED Back Light(less than 20,000 hours half-life at 25
o
C)
(Note 1)
Display Size
162 x 121.5mm
Operation System
Delta Real Time OS
MCU
HMI
32-bit RISC Micro-controller
Controller
32-bit DSP
NOR Flash ROM
Flash ROM 128 MB(OS System: 30MB / Backup: 16MB / User Application:
82MB)
SDRAM
64Mbytes
Backup Memory
(Bytes)
16Mbytes
Sound
Effect
Output
Buzzer
Multi-Tone Frequency (2K ~ 4K Hz)
/
85dB
AUX
Stereo output
Ethernet Interface
IEEE 802.3, IEEE 802.3u
10/100 Mbps auto-sensing
(
(has built-in isolated power circuit
(Note 3)
)
Memory Card
SD Card (supports SDHC)
USB
1 USB Host
(Note 2)
Ver 1.1 / 1 USB Slave Ver 2.0
Serial
COM
Port
COM1
RS-232
(
supports hardware flow control
)
COM2
RS-232
/
RS-422
/
RS-485
(
has built-in isolated power circuit
(Note 3)
)
COM3
RS-232
/
RS-422
/
RS-485
(
has built-in isolated power circuit
(Note 3)
)
Remote I/O
Specialized 10M bps RS-422
MODEL
HMC08-N500S52
Motion Control Bus
DMCNET
Function Key
N/A
Perpetual Calendar
Built-in
Cooling Method
Natural air circulation
Safety Approval
CE
/
UL
(Note 4)
/
KCC
(Note 4)
Waterproof Degree
IP65
/
NEMA4
Operation Voltage
(Note5)
DC +24V
(
-10% ~ +15%
)
(
has built-in isolated power circuit
(Note 3)
)
Voltage Endurance
AC500V for 1 minute (between charging (DC24V terminal)
and FG terminals)
Power Consumption
(Note 5)
11 W
Backup Battery
3V lithium battery CR2032 x 1
Backup Battery Life
It depends on the temperature used and the conditions of usage,
about 3 years or more at 25
o
C.
Operation
Temperature
0
o
C ~ 50
o
C
Storage Temperature
-20
o
C ~ +60
o
C
Ambient Humidity
10% ~ 90% RH
【
0 ~ 40
o
C
】,
10% ~ 55% RH
【
41 ~ 50
o
C
】,
Pollution Degree 2
Vibration
IEC 61131-2 compliant 5Hz
≦
f
<
8.3Hz = Continuous: 3.5mm, 8.3Hz
≦
f
≦
150Hz =
Continuous: 1.0g
Shock
IEC 60068-2-27 compliant 15g peak for 11 ms duration, X, Y, Z directions for 6
times
Dimensions
(W) x (H) x (D) mm
227.1 x 174.1 x 61
Panel Cutout
(W) x (H) mm
219.4 X 166.5
Weight
Approx.1314 g
NOTE
1)
The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25
o
C normal temperature and
humidity conditions.
2)
USB Host port can provide up to 5V/ 500mA of power.
3)
The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
4)
Some models are in the process of application to UL and KCC certification. For more information, please consult
our distributors.
5)
The value of the power consumption indicates the electrical power consumed by HMI only without connecting to
any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which
the capacity is 1.5 ~2 times the value of the power consumption.
6)
Users can download the Screen Editor V2.00, the program editor of Delta HMI product and the user manual via the
following link:
http://www.delta.com.tw/ia
.
7)
The content of this quick start may be revised without prior notice. Please consult our distributors or download the
most updated version at
http://www.delta.com.tw/ia
.