background image

 

(7)

 

Basic Inspection 

 

Item

 

Content

 

General Inspection 

  Periodically inspect the screws of the connection between the HMI and device. 

Tighten screws as necessary as they may loosen due to vibration and varying 
temperatures. 

  Ensure that oil, water, metallic particles or any foreign objects do not fall inside 

the HMI, control panel or ventilation slots and holes. As these will cause damage. 

  Ensure the correct installation and the control panel. It should be free from 

airborne dust, harmful gases or liquids. 

Inspection before 

operation (power is not 

applied) 

  Ensure that all wiring terminals are correctly insulated. 

  Ensure that all wiring is correct or damage and or malfunction may result. 

  Visually check to ensure that there are not any unused screws, metal strips, any 

conductive or inflammable materials inside HMI. 

  Ensure to lower electromagnetic interference when devices are influenced by it.

  Ensure that the external applied voltage to HMI is correct and matched to the 

controller. 

Inspection before 

operation (power is 

applied) 

  Check if power LED lights. 

  Check if the communication among devices is normal. 

  Please contact our local distributors or Delta sales representative if there are any 

abnormal conditions. 

 

(8)

 

Pin Definition of Serial Communication 

COM1 Port

Supports Flow Control

 

COM Port   

PIN 

Contact 
RS-232 

 
 

 

 

1  

RXD 

3 TXD 

 

5 GND 

 

7 RTS 

CTS 

9  

Note: Blank = No Connection. 

COM2 Port

Supports Flow Control

 

COM Port   

PIN 

MODE1 

MODE2 

MODE3 

RS-232 

RS-422 

RS-485 

 
 
 

 

1   TXD+ D+ 

RXD 

 

 

3 TXD 

 

 

 

RXD+ 

 

GND GND GND 

 

TXD- 

D- 

7 RTS 

 

 

CTS 

 

 

9  RXD-  

Note1: Blank = No Connection. 
Note2: When COM2 port is used for RS-232 flow control, i.e. RTS and CTS signals are used for flow control,   

COM3 port will become incapable of being used. 

Note3: When COM2 port is used for RS-422 flow control, please refer to the following COM3 Port signals table for 

pin assignments. The signals, RTS+, CTS+, RTS- and CTS- shown in brackets are the signals used for 
flow control.   

COM3 Port 

COM Port   

PIN 

MODE1 

MODE2 

MODE3 

RS-232 

RS-422 

RS-485 

 
 
 

 

1  

TXD+(RTS+) 

D+ 

RXD 

 

 

3 TXD 

 

 

 

RXD+(CTS+) 

 

GND GND GND 

 

TXD-(RTS-) 

D- 

7  

 

 

 

 

 

9   RXD-(CTS-)  

Note1: Blank = No Connection. 
Note2: When COM2 port is used for RS-422 flow control, please refer to the COM3 Port signals table above for pin 

assignments. The signals, RTS+, CTS+, RTS- and CTS- shown in brackets are the signals used for flow control.   

 

Ethernet Interface (LAN) 

Ethernet Interface (LAN) 

PIN 

Contact 

Ethernet 

 

 

 

1 TX+ 

TX- 

3 RX+ 

 

5  

RX- 

7  

 

Note: Blank = No Connection. 

 

DMCNET 

Ethernet Interface(LAN) 

PIN 

MODE 

 

 

 

1 D1+ 

D1- 

3 D2+ 

 

5  

D2- 

7  

 

Note: Blank = No Connection. 

Remote Module 

Ethernet Interface (LAN) 

PIN 

Contact 

 

 

 

1  

 

3  

TX+ 

5 TX- 

 

7 RX+ 

RX- 

Note: Blank = No Connection. 
 

(9) Dimensions 

HMC08-N500S52 

T=1.6mm(0.06") ~

5.0mm(0.19")

(2.06")

174.

1(

6.

85")

227.1(8.94")

 0

+0.04"

(8.63"        )

 0

219.4

+1

+0

.04"

6.

55"  

    

 

 0

+1

 166.

5  

 

 0

NOTE:

4-

R1

.0

(0

.0

4"

)

52.3

T

 

 (10) Specifications 

 

MODEL

 

HMC08-N500S52 

LCD MO

DULE

Display Type 

8” TFT LCD (65536

 colors

Resolution 

800 x 600 pixels 

Backlight 

LED Back Light(less than 20,000 hours half-life at 25

o

C) 

(Note 1)

 

Display Size 

162 x 121.5mm 

Operation System 

Delta Real Time OS 

MCU 

HMI 

32-bit RISC Micro-controller 

Controller 

32-bit DSP 

NOR Flash ROM 

Flash ROM 128 MB(OS System: 30MB / Backup: 16MB / User Application: 

82MB) 

SDRAM 

64Mbytes 

Backup Memory 

(Bytes) 

16Mbytes 

Sound 

Effect 

Output 

Buzzer 

Multi-Tone Frequency (2K ~ 4K Hz) 

85dB  

AUX 

Stereo output 

Ethernet Interface 

IEEE 802.3, IEEE 802.3u 

10/100 Mbps auto-sensing

(has built-in isolated power circuit 

(Note 3)

 

Memory Card 

SD Card (supports SDHC) 

USB 

1 USB Host 

(Note 2)

 Ver 1.1 / 1 USB Slave Ver 2.0 

Serial 

COM 

Port 

COM1 

RS-232

supports hardware flow control

 

COM2 

RS-232

RS-422

RS-485 

has built-in isolated power circuit

 (Note 3)

 

COM3 

RS-232

RS-422

RS-485 

has built-in isolated power circuit

 (Note 3)

 

Remote I/O 

Specialized 10M bps RS-422 

MODEL

 

HMC08-N500S52 

Motion Control Bus 

DMCNET  

Function Key 

N/A 

Perpetual Calendar 

Built-in 

Cooling Method 

Natural air circulation 

Safety Approval 

CE

UL 

(Note 4)

 

KCC 

(Note 4)

 

Waterproof Degree 

IP65

NEMA4

 

Operation Voltage

 

(Note5)

 

DC +24V

-10% ~ +15%

 

has built-in isolated power circuit

 (Note 3)

 

Voltage Endurance 

AC500V for 1 minute (between charging (DC24V terminal)   

and FG terminals) 

Power Consumption

 

(Note 5)

 

11 W   

Backup Battery 

3V lithium battery CR2032 x 1 

Backup Battery Life 

It depends on the temperature used and the conditions of usage,   

about 3 years or more at 25

o

C. 

Operation 

Temperature 

0

o

C ~ 50

o

Storage Temperature 

-20

o

C ~ +60

o

Ambient Humidity 

10% ~ 90% RH

0 ~ 40

o

C

】,

10% ~ 55% RH

41 ~ 50

o

C

】,

Pollution Degree 2

Vibration 

IEC 61131-2 compliant 5Hz

f

8.3Hz = Continuous: 3.5mm, 8.3Hz

f

150Hz = 

Continuous: 1.0g 

Shock 

IEC 60068-2-27 compliant 15g peak for 11 ms duration, X, Y, Z directions for 6 

times 

Dimensions 

(W) x (H) x (D) mm 

227.1 x 174.1 x 61 

Panel Cutout 

(W) x (H) mm 

219.4 X 166.5 

Weight 

Approx.1314 g 

 

 

NOTE

 

1) 

The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current 
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25

o

C normal temperature and 

humidity conditions. 

2) 

USB Host port can provide up to 5V/ 500mA of power. 

3) 

The withstand voltage of the isolated power circuit is 1500V peak for 1 minute. 

4) 

Some models are in the process of application to UL and KCC certification. For more information, please consult 
our distributors. 

5) 

The value of the power consumption indicates the electrical power consumed by HMI only without connecting to 
any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which 
the capacity is 1.5 ~2 times the value of the power consumption. 

6) 

Users can download the Screen Editor V2.00, the program editor of Delta HMI product and the user manual via the 
following link: 

http://www.delta.com.tw/ia

.  

7) 

The content of this quick start may be revised without prior notice. Please consult our distributors or download the 
most updated version at 

http://www.delta.com.tw/ia

.

 

 

 

 

  PIN1

 

  PIN1

 

  PIN1

 

Summary of Contents for HMC08

Page 1: ...Method Do not use a voltage that will exceed specification for the HMI Failure to observe this caution may result in electric shock or fire Remove the terminal block from the HMI before wiring Insert...

Page 2: ...pe 8 TFT LCD 65536 colors Resolution 800 x 600 pixels Backlight LED Back Light less than 20 000 hours half life at 25 o C Note 1 Display Size 162 x 121 5mm Operation System Delta Real Time OS MCU HMI...

Page 3: ...belirtilen de erlerin d nda voltaj uygulamay n z Aksi halde elektrik oku veya yang na sebep olabilir Kablo ba lant s yapmadan nce terminal blo unu HMI dan ay r n z Terminal blo undaki her bir terminal...

Page 4: ...4 R 1 0 0 04 52 3 T 10 zellikler MODEL HMC08 N500S52 LCD MOD L Display Tipi 8 TFT LCD 65536 renk z n rl k 800 x 600 pixel Ayd nlatma LED Ayd nlatma 25 o C yar m m rde 20 000 saatten az Not 1 Display...

Page 5: ...1 HMC HMI with Controller 2 LCM 08 8 TFT LCD 3 N 4 5 SVGA 5 6 S Standard 7 5 DMCNET 8 Remote Unit 2 RS 422 4 HMC08 N500S52 A B C HMC08 N500S52 A G USB Host B COM3 H C COM2 I D COM1 J DMCNET E USB Sla...

Page 6: ...ote 1 162 x 121 5mm Delta Real Time OS HMI 32 bit RISC Micro controller 32 bit DSP ROM Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 64Mbytes Bytes 16Mbytes Multi Tone Freque...

Page 7: ...1 HMC HMI with Controller 2 LCM 08 8 TFT LCD 3 N 4 5 SVGA 5 6 S Standard 7 5 DMCNET 8 Remote Unit 2 RS 422 4 HMC08 N500S52 A B C HMC08 N500S52 A G USB Host B COM3 H C COM2 I D COM1 J DMCNET E USB Sla...

Page 8: ...ote 1 162 x 121 5mm Delta Real Time OS HMI 32 bit RISC Micro controller 32 bit DSP ROM Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 64Mbytes Bytes 16Mbytes Multi Tone Freque...

Reviews: