background image

 

 

HMC07

-N4

 

High Color

Motion Inside

User-Friendly HMI Products 

 

No.18, Xinglong Rd., Taoyuan City 

33068, Taiwan 

Instruction Sheet

 

(1) Preface 

Thank you for purchasing HMC07-N4. This instruction sheet provides for some related information of HMC07-N4 H 
series. Before using the product, please read through this manual carefully in order to ensure the correct use of the 
product. In addition, please place this manual safely for quick reference whenever is needed. Please follow the rules 
below if you have not finished reading this manual yet. 

 

Install the product in a clean and dry location free from corrosive and inflammable gases or liquids. 

 

Ensure that all wiring instructions and recommendations are followed. 

 

Ensure that HMI is correctly connected to the ground. The grounding method must comply with the national 
electrical standard (Please refer to NFPA 70: National Electrical Code, 2005 Ed.). 

 

Do not modify the wiring when power is applied to HMI. 

 

Do not touch the power supply during operation. Otherwise, it may cause electric shock. 

If you have any enquiry during operation, please contact our local distributors or Delta sales representatives.   
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the 
latest version at 

http://www.delta.com.tw/ia

 

(2) Safety Precautions 

Carefully note and observe the following safety precautions during inspecting, installation, operating, maintenance and 
troubleshooting. 

Installation 

 

  Comply with instruction mentioned in this instruction sheet for installation. Otherwise it may damage 

the equipment. 

  Do not expose the product to the environment which containing water, corrosive gas, inflammable gas. 

Or it may result in electric shock, fire, or explosion. 

  Do not install the product in a location where temperatures will exceed specification for the HMI. 

Failure to observe this caution may result in abnormal operation or damage to the product. Please 
refer to the specifications that listed on the second page. 

  This product has the approval of KCC Class A, which is for commercial or industrial use only. Home 

use product is classified as KCC Class B. 

  Do not place this product where that may result in personal injury, equipment damage, or cause 

emergency stop. 

Wiring 

 

  Connect the ground terminals to class-3 ground system (Ground resistance should not exceed 100 

). 

Improper grounding may result in communication error, electric shock or fire. 

  Do not connect to other wire rods to extend the cable length. Or it may cause poor communication or 

malfunction. 

Operation 

 

  When designing HMI programs, if the interface is not programmed well, it may cause the abnormal 

operation. Therefore, in order to prevent personal injury or equipment damage, make sure that the 
communication error caused by the interface, controller or equipment would not lead to the 
malfunction of the product. 

  Please backup the screen data and HMI programs in case the data is lost. 

  When not in use, please place the HMI at a flat surface or use the hook on the back to hang it properly 

to avoid risks of falling or crash. 

 

 

  Do not modify the wiring during operation. Otherwise it may result in electric shock or personal injury. 

  Never use a sharp object to touch or hit the screen as doing this may damage the screen and cause 

malfunction of HMI. 

Maintenance and Inspection 

 

  Do not touch any internal parts of the HMI as this may damage the product or cause electric shock. 

  Wait at least 10 minutes after the power is removed before touching any HMI terminals or performing 

any wiring and/or inspection.

 

Or the residual voltage may cause electric shock. 

Wiring Method 

 

  The voltage applied shall not exceed specification for the HMI. Failure to observe this caution may 

result in electric shock or fire. 

  If any cable is forced removed, please make sure to check the connection again before resuming the 

operation. 

Communication Wiring 

 

  Comply with communication wiring specification for wiring. 

  To avoid noise and interference, the communication cable, all power cables, and motor power cable 

should be placed in separate conduits. 

 
 
 
 
 
 
 
 
 
 
 

(3) Model Explanation 

HMC 07

-

N

4  11

H  5  C  5 

(1) (2)

 

(3)

(4)

(5)

(6) (7)

(8)

(9)

 

(1) Product 

Name 

HMC

: HMI with Controller

 

(2) LCM 

Size 

07

 : 7.0" TFT   

 

(3) Type 

N

: General type 

(4) 

Display

 

Specification 

4

: WVGA (800x480) 

(5) Version 

number 

10

11

 

(6) Series 

H

: Hand-held 

(7) 

External control 
interface (Bus) 

5

: DMCNET 

(8) External 

Device 

Device

Code

Handwheel

SD SD+USB

 

 

 

 

 

 

(9) Cable 

Length 

5

: 5 m 

A

: 10 m 

 

 

(4) Parts Names 

 

HMC07-N411H5CX (Front View)

 

 

LED Power Indicator 

Function Keys 

Touch Screen / Display 

Emergency Stop 

Handwheel 

 

 

HMC07-N411H5CX (Rear View) 

 

A

3-Position Operation Switch

B

Cable 

C

Hook 

HMC07-N411H5CX (Bottom View) 

 

 
 
 
(5) Ambient Conditions of Installation and Storage 

The product should be kept in the shipping carton before installation. In order to retain the warranty coverage, the HMI 
should be stored properly when it is not used for an extended period of time. Some storage suggestions are: 

 

Store in a clean and dry location 

 

Store within an ambient temperature range of -10°C to +60°C (-14°F to 140°F). 

 

Store within a relative humidity range of 10% to 90% and in a non-condensing environment. 

 

Do not store the HMI in a place subjected to corrosive gases and liquids. 

 

Correctly pack and place the product on a solid and durable surface. 

 

The ambient conditions of installation should NOT include: over-heat device; water drop, vapor, dust and oily 
dust; corrosive and inflammable gas and liquid; airborne dust and metal particles; interference of 
electromagnetic noise; and should have solid foundation and no vibration. 

(6) Wiring Method 

Wire of HMC07-N4 

 

 

Cable Definition

 

Color of Skinned Wire 

Function 

White / Purple 

Emergency Stop 1 – NC(B) 

White / Green 

Emergency Stop 1 – NC(B) 

Blue 

Emergency Stop 2 – NC(B) 

White / Blue 

Emergency Stop 2 – NC(B) 

Yellow RS-485 

(+) 

White / Yellow 

RS-485 (-) 

White / Black 

Grounding for Communication   

Brown 

Grounding for Communication   

White / Brown 

Grounding for Communication 

Red DC 

24V 

Black 0V 

White 

FGND (Power ground) 

White & Red 

N/A 

RJ-45 (Blue) 

DMCNET 

 
 

Note 

Note 

Correctly connect to the remote module or ASDA series 
servo drive according to the recommended direction of 
RJ-45. 

 

Leave at least 60 mm for connection. Do not over-bend 
the cable. 
 

 

 
 
 
 
 
 
 

USB Slave 

SD Card 

A

B

Summary of Contents for HMC07-N4

Page 1: ...on the back to hang it properly to avoid risks of falling or crash Do not modify the wiring during operation Otherwise it may result in electric shock or personal injury Never use a sharp object to touch or hit the screen as doing this may damage the screen and cause malfunction of HMI Maintenance and Inspection Do not touch any internal parts of the HMI as this may damage the product or cause ele...

Page 2: ...Minimum allowable load DC 5V 1 mA 3 Position Operation Switch For internal use No output signal Handwheel For internal use No output signal Function Keys 15 Function Keys Cable Length 5M 10M Perpetual Calendar Built in Cooling Method Natural cooling Safety Approval CE Note 3 Waterproof Level of Panel Display IP55 Operation Voltage DC 24V 15 Note 5 Voltage Endurance AC500V for 1 minute between char...

Page 3: ...örebilir veya elektrik şoku meydana gelebilir Enerjiyi kestikten sonra HMI terminallerine dokunmadan önce 10 dakika bekleyiniz Aksi halde kalan voltaj elektrik şokuna sebep olabilir Bağlantı Metodu HMI besleme voltajı direktiflerinde belirtilen aralığın dışında olmamalıdır Aksi halde elektrik şoku veya yangına sebep olabilir Eğer herhangi bir kablo yerinden çıkmış ise çalışmaya başlamadan önce bağ...

Page 4: ...ğı 1 dakika için AC500V DC 24V terminali ve FG terminalleri arasında Güç Tüketimi 6W Not 4 Backup Pil Dahili 3V lityum pil Backup Pil Ömrü Kullanım sırasındaki belirtilen koşullar ve sıcaklık altında 25 o C de 5 yıl veya daha fazla Çalışma Sıcaklığı 0o C 40o C Saklama Sıcaklığı 10o C 60o C Çalışma Ortamı 10 90 RH 0 40o C 10 55 RH 41 50o C Kirlenme Derecesi 2 Titreşim IEC61131 2 uyumlu Sürekli 5 Hz...

Page 5: ...壞 不得在開啟電源情況下改變配線 否則可能造成觸電或人員受傷 請勿以尖銳物品碰觸面板 否則可能導致面板凹陷 進而無法使人機介面正常運作 保養及檢查 禁止接觸人機介面內部 否則可能會造成觸電或產品損壞 電源關閉 10 分鐘內 不得接觸接線端子 殘餘電壓可能造成觸電 配線方法 請勿使用超過人機介面規格範圍的電壓 否則可能會引起產品損壞 觸電或火災 對於錯誤強行拔出電線的動作 請重新檢查連接電線再啟動 通訊電路的配線 採用正確的接地迴路 以避免通訊不良 為防止較大的雜訊干擾引起人機介面無法正常運作 請用單獨的配線槽將人機介面的通訊電纜和所有電 源線及馬達動力線分開 3 型號說明 HMC 07 N 4 11 H 5 C 5 1 2 3 4 5 6 7 8 9 1 產品名稱 HMC HMI with Controller 2 LCM尺寸 07 7 0 TFT 3 行業類別 N 泛用 4 顯示規格 4...

Page 6: ...Slave Ver 2 0 外部記憶體 SD SDHC 緊急停止按鈕 Push lock switch Output 2 contacts B 接點 normally close x 2 額定電壓 DC 30V 最大額定電流 500mA 最小適用負載 DC 5V 1mA 三段式操作按鈕 內部使用 無對外輸出訊號 手搖輪 內部使用 無對外輸出訊號 輔助鍵 15 Function Keys 總線長度 5M 10M 萬年曆 內建 冷卻方式 自然冷卻 安規認證 CE Note 3 面板防水等級 IP55 工作電壓 DC 24V 15 Note 5 絕緣耐力 DC24 端子與 FG 端子間 AC500V 1 分鐘 主機消耗功率 6W Note 4 記憶體備份電池 內建 3V 鋰電池 備份電池壽命 依使用環境溫度及使用條件而不同 常溫 25o C 下壽命約五年以上 操作溫度 0o C 40o C 儲存...

Page 7: ...配线方法 请勿使用超过人机界面规格范围的电压 否则可能会引起产品损坏 触电或火灾 对于错误强行拔出电线的动作 请重新检查连接电线再启动 通讯电路的配线 采用正确的接地回路 以避免通讯不良 为防止较大的噪声干扰引起人机界面无法正常运作 请用单独的配线槽将人机界面的通讯电缆和所有电 源线及马达动力线分开 3 型号说明 HMC 07 N 4 11 H 5 C 5 1 2 3 4 5 6 7 8 9 1 产品名称 HMC HMI with Controller 2 LCM尺寸 07 7 0 TFT 3 行业类别 N 泛用 4 显示规格 4 WVGA 800x480 5 版本标识符 10 11 6 系列名 H Hand held 手持式 7 控制 总线接口 5 DMCNet 8 外部装置 装置 代码 手动脉冲发 生器 SD SD USB 2 C 9 出线长度 5 5米 A 10米 4 产品说明 HM...

Page 8: ... 三段式操作按钮 内部使用 无对外输出讯号 手动脉冲发生器 内部使用 无对外输出讯号 辅助键 15 Function Keys 总线长度 5M 10M 万年历 内建 冷却方式 自然冷却 安规认证 CE Note 3 面板防水等级 IP55 工作电压 DC 24V 15 Note 5 绝缘耐力 DC24 端子与 FG 端子间 AC500V 1 分钟 主机消耗功率 6W Note 4 内存备份电池 内建 3V 锂电池 备份电池寿命 依使用环境温度及使用条件而不同 常温 25o C 下寿命约五年以上 操作温度 0o C 40o C 储存温度 10o C 60o C 工作环境 10 90 RH 0 40o C 10 55 RH 41 50o C 污染等级 2 耐震动 IEC61131 2 规定连续振动 5Hz 8 3Hz 3 5mm 8 3Hz 150Hz 1G 耐冲击 IEC60068 2 27...