9.  Reclaim 

At the end of the unit working life, the produce must not be disposed of as urban waste. 
It must be taken to a special local authority differentiated waste collection center or to a 
dealer providing this service.   

 

 

 

Summary of Contents for HEX110QA

Page 1: ...EX110QA Rev 00 Sample Date Code Sample Issue Date June 2 2020 DELTA ELECTRONICS INC 252 SHANG YING ROAD KUEI SAN TEL 886 0 3 3591968 TAOYUAN CITY 333 TAIWAN FAX 886 0 3 3591991 Please send one copy of...

Page 2: ...mber 7 1 3 Dimension 9 1 4 Mounting Panel Cutout 10 1 5 Configuration Maintenance 11 1 6 Thermal and Airflow 12 2 Electrical Specification 13 2 1 Indicator Connector 13 2 2 Cooling capacity temperatur...

Page 3: ...with care Do not place heavy objects on top of the box Pay attention to the below icons on the package Please check product function by self test process and make sure no alarm signal and abnormal aco...

Page 4: ...at has leaked from refrigerant pipes or other areas as there is a danger of frostbite 6 Before serving or cleaning unit switch power off and disconnect power supply 7 When cutting or drilling into wal...

Page 5: ...ace where there is a danger or flammable gas leakage 5 Arrange the drain to ensure complete drainage 6 To avoid injury do not touch the air inlet or aluminum fins of the unit 7 Watch your step at the...

Page 6: ...el no HEX110QA Page 6 Specification for Approval Customer Description Heat Exchanger 110W K Customer P N Rev Delta model no HEX110QA Rev 00A Sample revision Date Code Sample issue date Quantity 1 pcs...

Page 7: ...del Number Dimensions Weight Mounting method Dimension H x W x D without flange mm inch 536 x 447 x 220 21 1 x 17 6 x 8 7 Application Outdoor Weight Kg lbs 15 0 33 1 Mounting Method Roof Color optiona...

Page 8: ...nal Airflow m3 h CMH 400 Power Range Input Voltage VDC 48 Input Voltage Range VDC 40 60 Rated DC Current A 5 0 Alarm N A Dry Contact Output Key Components Controller Built in Smart Controller Communic...

Page 9: ...Part no Delta model no HEX110QA Page 9 1 3 Dimension 1 Material Aluminum sheet t 1 5mm 2 Finish Powder painting 75um MIN 3 Color RAL 7035 3 Dimension tolerance X X 1 0 mm mm...

Page 10: ...Part no Delta model no HEX110QA Page 10 1 4 Mounting Panel Cutout M5 SCREW WITH SKIDPROOF WASHER OR NYLOK 20X SYSTEM PANEL EXTERNAL SIDE INTERNAL SIDE AND SYSTEM PANEL...

Page 11: ...lean the core with water directly The external side fan blade can also be cleaned with normal pressure water if there is dust accumulation Please do not use strong water jet to impact the center of fa...

Page 12: ...arm air generated by the equipment will be blowing into the internal return opening and pass though the HEX then flow out from internal supply opening the cold supply air will be used to cool down the...

Page 13: ...m N C dry contact 6 RS485 A Reserved 7 RS485 B Reserved Alarm contact rating max 60VDC 100mA 2 LED Indicator Mate with DINKLE 2ESDVM 07P HEX status FAN SENSOR Power off Dark Dark HEX normal power on G...

Page 14: ...ting Temperature 10 C 55 C 14 F 131 F Storage Temperature 40 C 70 C 40 F 158 F Operation Humidity External air loop 0 100 RH Internal air loop 0 90 RH non condensing Ingress Protection Rating IP55 IEC...

Page 15: ...gh temp High humidity IEC 60068 2 3 Temperature cycle IEC 60068 2 14 test Nb Vibration ETSI 300 019 1 4 CLASS 4 1 Ingress protection external side IEC 60529 IP55 NEMA TYPE 4 Salt fog test external sid...

Page 16: ...X capacity is not match the load of the system The ambient temperature is too high Low efficiency of the outside Other system failure Check the heating load of the system Ensure the TEC is operating i...

Page 17: ...A Page 17 9 Reclaim At the end of the unit working life the produce must not be disposed of as urban waste It must be taken to a special local authority differentiated waste collection center or to a...

Page 18: ...Part no Delta model no HEX110QA Page 18 10 Versions REV DESCRIPTION DRAWN CHECKED APPROVED ISSUE DATE ME EE CE 00 ISSUE SPEC KC Liao KC Liao Ted Tu Mars Wu 2020 6 02...