Delta HEH080BB Specification And Manual Download Page 12

Part no.:   

Delta model no.: HEH080BB 

 

 

Page 12   

2-2 Protection 

 

Over Temperature Protection: 

Thermostat 1: Off temperature operation range: -20~40°C 

  Fuse: Cut-out temperature: 167°C  

 

3.  Environmental Condition

 

 

Operating Temperature 

-30 °C ~ +40 °C (-22 °F ~ +104 °F) 

 

Storage Temperature   

-40 °C ~ +75 °C (-40 °F ~ 167 °F) 

 

Operation Humidity 

Internal air loop: 0 ~ 90 % RH, non-condensing 

 

Ingress Protection Rating 

IP20 (IEC60529)   

 

4. Reliability Table 

Test item

 

 

Condition

 

 

High temperature 

IEC 60068-2-2 

Low temperature 

IEC 60068-2-1 

High temp. /High humidity 

IEC 60068-2-14 TEST Nb 

Temperature cycle 

IEC 60068-2-3 

Vibration 

ETSI 300 019-1-4 CLASS 4.1 

Package bump 

IEC 60068-2-29 

 

 

MTBF 

The L10 Fan life is expected to be at least 80,000 hours continuous operation 

at 40°Cwith 15 ~ 65%RH .@ label rated voltage. 

 

5.  Safety Certification 

UL File E358666 

 

Summary of Contents for HEH080BB

Page 1: ...BB Rev 04 Sample Date Code Sample Issue Date MAY 29 2020 DELTA ELECTRONICS INC TAOYUAN PLANT TEL 886 0 3 3591968 252 SHANGYING ROAD GUISHAN INDUSTRIAL ZONE FAX 886 0 3 3591991 TAOYUAN CITY 33341 TAIWA...

Page 2: ...ion 7 1 1 General Description 7 1 2 Main Feature Model Number 7 1 3 Dimension 9 1 4 Thermal and Airflow 10 2 Electrical Specification 11 2 1 Indicator Connector 11 2 2 Protection 12 3 Environmental Co...

Page 3: ...nstalling heater read these instructions carefully Failure to follow these instructions could damage the product or cause a hazardous condition 2 Check the ratings on the heater label to assure the pr...

Page 4: ...ock Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules 10 This appliance is intended for use only by qualified personnel Caution Do not use these elec...

Page 5: ...ance is not to be used by any persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given proper supervision or instruction 6 Children...

Page 6: ...no HEH080BB Page 6 Specification for Approval Customer Description Heater for Equipment Wall Mounting Customer P N Rev Delta model no HEH080BB Rev 04 Sample revision Date Code Sample issue date MAY 29...

Page 7: ...ght Mounting method Dimension H x W x D without flange mm inch 187 x 108 x 79 5 7 4 x 4 3 x 3 1 Application Indoor Weight Kg lbs 0 8 1 8 Mounting Method Door Side Color optional Silver Environmental P...

Page 8: ...A Fans Delta High Efficiency Fan The Heating capacity W is defined as W V A at 0 oC W power consumption V Operating Voltage A Operating current Test condition are AC input 230Vac that is cold start at...

Page 9: ...ect at the bottom and the air outlet at the top as shown 4 The recommended clearances shown by the shadowed area indicates the space that should be kept free for optimum operation of the heater and sa...

Page 10: ...re sensor has been placed in the return air for safe operation Cool air flows into the heater and warmed up by PTC heating element inside of case then supplied to the system Minimum gap for both of co...

Page 11: ...20 40 C Fuse Cut out temperature 167 C Note DC Fan is powered by adapter AC DC convert The on off temperature by user to setup Startup average current and inrush current The startup average and inrus...

Page 12: ...ity Internal air loop 0 90 RH non condensing Ingress Protection Rating IP20 IEC60529 4 Reliability Table Test item Condition High temperature IEC 60068 2 2 Low temperature IEC 60068 2 1 High temp High...

Page 13: ...ter failure Check the ambient temperature to define heater Is failure or not Please contact Delta or authorized Delta service agent Power on the Fan is stop but the heating is enable at low temp condi...

Page 14: ...SSUE SPEC VIC PAN 04 26 19 VIC PAN 04 26 19 Ted Tu 04 26 19 Diamond CHEN CW CHEN 04 26 19 09 05 18 01 Modify model no VIC PAN 01 28 19 VIC PAN 04 18 19 Ted Tu 04 18 19 Diamond CHEN CW CHEN 04 18 19 04...

Reviews: