MODELS: GBR80HLED, GBR80LED, GBR80MHLED, GBR100HLED, GBR100LED
SUPPLIED ACCESSORIES
Part name
Appearance
Quantity
Grille
1
Fan
1
Housing
1
Duct Connector
(4’’)
1
Long Wood Screw
(ø4×25)
8
Machine Screw
(#8-32x5/16’’)
4
Suspension Bracket
4
INSTALLATIONS
Proper insulation around the fan to minimize building heat loss and
gain.
4’’ circular duct is recommended for installation. The ducting
from this fan to the outside of the building has a strong effect on
the air flow, noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance, and avoid
installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth.
Fans installed with existing ducts may not achieve their rated air
flow.
Roof cap
(with built-in damper)
Seal gap
around
housing
Caulk termination
to duct
Fan housing
Short piece of flexible
duct helps alignment
and absorbs sound
Wall cap
(with built-in damper)
or
MOUNT
MOUNT
MOUNT
MOUNT HOUSING
HOUSING
HOUSING
HOUSING WITH
WITH
WITH
WITH FLANGE:
FLANGE:
FLANGE:
FLANGE:
1.
To bend the housing tabs out to 90 degree and make
housing tabs contact the bottom of the joist.
Joist
Tabs
2.
The housing mounts with 4 l
ong wood screw
(
Ø
4×25).
Screw housing to joist through lowest holes in each
mounting flange, then through the other holes.
Joist
Long Wood Screw
( 4×25)
USING SUSPENSION BRACKETS
USING SUSPENSION BRACKETS
USING SUSPENSION BRACKETS
USING SUSPENSION BRACKETS
3.
Sliding suspension brackets available to allow for your
specific positioning of housing anywhere between joists
and span up to 24’’.
Suspension Bracket
4.
Extend suspension brackets to the width of the joists. Make
sure the fan body is level and perpendicular with the joist.
5.
Secure suspension brackets to joists with long wood screw
(ø4×25)
.
6.
Secure suspension brackets together with machine screw
(#8-32x5/16’’)
.
(#8-32x5/16”)
Joist
Joist