background image

                                                                                                                                 

 

 

 

 

 

MODEL 

FRS200/VDB200F6D1 

Page 3.

DUCT CONNECTION 

1.

 

Remove the tape stuck on damper before duct 
connection and make sure the damp is closed by 
gravity. 

2.

 

Attach the 6’’ duct (not provided) onto the duct 
connector and tape all ductwork connections to 
make them secure and airtight. (Fig. O) 

3.

 

Install the duct with a gradient 1°~2° to the 
outside. 

Ceiling

Body

Tape

Duct

Outside

Gradient

1°~2°

Inside

Duct connector

Fig. O 

CONNECT WIRING 

1.

 

Follow all local electrical code and ANSI/NFPA70. 

2.

 

NEVER place a switch where it can be reached 
from a tub or shower. 

3.

 

Connect wires as shown in wiring diagrams. 

OFF

ON

L

N

POWER SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

GREEN

GRD

  Fig. P

   

 

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE

GROUND

(bare)

POWER
SWITCH

WIRING

PLATE

  Fig. Q 

 

4.

 

Using wire nuts (not provided), connect the 
house power cable to the ventilating fan wires. 

5.

 

14 AWG (2.1 mm

2

) is the smallest conductor that 

shall be used for branch-circuit wiring. 

OPERATION 

1.

 

Turn the POWER switch on to operate. 

 

 

MAINTENANCE

 

WARNING

 

Disconnect the power source before working on the 
unit. Routine maintenance must be done every year. 

CAUTION: 

1.

 

Never use gasoline, benzene, thinner or any other 
such chemicals to clean the supply air fan. 

2.

 

Do not allow water to enter the motor. 

3.

 

Do not soak resin parts in water over 140°F 
(60°C). 

CLEANING 

1.

 

Open the filter maintenance cover by turning the 
hand screw counterclockwise. (Fig. R) 

 

Fig. R 

2.

 

Pull out the pre-filter, clean it with water once in 
3 months. (Fig. S) 

 

Fig. S

 

3.

 

Pull out the MERV filter (optional), clean it with 
vacuum cleaner once in 3 months, and replace it 
once in 6 months. (Fig. T) 

 

Fig. T 

4.

 

Reinstall the filters and close the maintenance 
cover by turning the screw clockwise. 

 

DIMENSIONS 

  Fig. U 

WARRANTY 

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY 

 

Delta  Electronics  Inc.  (‘‘Delta  Electronics’’)  warrants  to  the 
original consumer purchaser in the USA

 

and  Canada

 

that the 

Breez  ventilation  fan  products  will  be  free  from  defects  in 
material or workmanship. This warranty is limited to three (3) 
years from the original date of purchase. 
Limitations and Exclusions

Limitations and Exclusions

Limitations and Exclusions

Limitations and Exclusions   
1. During the warranty period, a replacement for any defective 

product  will  be  supplied  free  of  charge  for  installation  by 
the consumer. The warranty provided herein does not cover 
charges  for  labor  or  other  costs  incurred  in  the 
troubleshooting, repair, removal, and installation service. 

2.  All  returns  of  defective  parts  or  products  must  include  the 

product  model  number,  and  must  be  made  through  an 
authorized Delta Electronics distributor. Authorized returns 
must  be  shipped  prepaid.  Repaired  or  replacement 
products  will  be  shipped  by  Delta  Electronics  F.O.B. 
shipping point. 

3.  Delta  Electronics  shall  not  be  liable  for  any  indirect, 

incidental,  consequential,  punitive,  or  special  damages 
arising  out  of  or  in  connection  with  products  use  or 
performance,  regardless  of  the  form  of  action  whether  in 
contract,  tort  (including  negligence),  strict  product  liability 
or otherwise.   

4.  This  warranty  does  not  extend to  fluorescent  lamp starters 

and tubes. 

5.  The  warranty  does  not  cover  if  user  does  not  comply  with 

manufacturer’s installation manual. 

6.  To  qualify  for  warranty  service,  you  must  notify  Delta 

Electronics at the address or telephone number below. 

7.  Delta  Electronics  shall  have  no  liability  to  the  original 

owner-user  with  respect  to  any  defect  caused  by  abuse, 
misuse,  neglect,  improper  transportation  or  storage, 
improper 

testing, 

improper 

installation, 

improper 

operation,  improper  use,  improper  maintenance,  improper 
repair, 

improper 

alteration, 

improper 

modification, 

tampering  or  accident  of  products  or  parts  thereof,  or 
unusual  deterioration  or  degradation  of  products  or  parts 
thereof  due  to  a  physical  environment  beyond  the 
requirements of products’ specifications. 

 

Address: 46101 Fremont Boulevard, Fremont , CA 94538 US 
Toll Free Number: 1-888-979-9889 

 

 

Summary of Contents for FRS200/VDB200F6D1

Page 1: ...llow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be ve...

Page 2: ...g F 2 Make sure the duct connector tab inserted to the flange and secure the duct connector by screw Fig G Fig G Install the housing I Suspended ceiling 1 Assemble bracket to body Fig H Suspend body with anchor bolts Fig I Fig H Fig I Install the housing II Attic Mount 1 Using 4 screws Ø 4x10 install the brackets on the unit and using 4 screws Ø 4x25 secure the unit to the joists or cross framing ...

Page 3: ...r purchaser in the USA and Canada that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions Limitations and Exclusions Limitations and Exclusions Limitations and Exclusions 1 During the warranty period a replacement for any defective product will be supplied fr...

Page 4: ...smaller duct 5 Fan body not securely attached 6 Filter is clogged 1 Be sure the CFM rating on the fan matches the size of your room 2 Check damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be s...

Reviews: