除t雾
明
Light
Defog
溫度設定
除霜時間
Defrost
Operation
Temp
Temp. Set
SET
MADE IN TAIWAN
Hold for
3 seconds to
power on/off
POWER
ON/OFF
DOWN
DEFOG
LIGHT
UP
SET
1. Manual Defrost/Stop Defrost
Hold and
for 5 seconds.
2. Panel Parameter Lock
Hold and
SET
for 3 seconds. DIsplay “00” for lock status and “33” for
unlock status. When locked, only setpoint is able for setting.
3. Evaporator temperature
Hold for one second to display. It will switch back to indoor tempera-
ture after 3 seconds. The rest parameter setting cannot be changed.
4. Parameter Value Increase
Value increase with button pressed.
5. Default Setting Restore:
Unplug the power line, hole and
SET
then plug in to display rS.
1. Panel Parameter Lock
Hold and
SET
for 3 seconds. DIsplay “00” for lock status and
“33” for unlock status.
When locked, only setpoint is able for setting.
2. User’s Parameter Option
Hold
SET
for 3 seconds to enter parameter setting. “Temp. Set”
is ON. Press
SET
for one second, the parameter can be adjusted
accordingly.
3.Release Quick Setting Mode
In quick setting mode, press
SET
or any other button.
4. Default Setting Restore:
Unplug the power line, hole and
SET
then plug in to
display rS.
1. Manual Defrost/Stop Defrost
Hold and
for 5 seconds.
2. Quick Setting
Press
for one second, then press or
to adjust setpoint.
If no action occurs within 5 seconds, or press
SET
directly to restore
parameter automatically, and indoor temperature displayed.
Up: ON
Down: OFF
Up: ON
Down: OFF
RS-617S
Button Instruction
Wiring Instruction
G
G
G
G
P11
P12
AC1
AC1
AC1
AC1
P13
FAN
COMP
DEFROST
LIGHT
DEFOG
RLY5
FAN
RLY4
1.5HP/240VAC
1HP/120VAC
DEFROST
COMP
10A
Compr
essor pr
otection contact
P7
2A
1
2
AC2
P5
NEB
1 3W
AC110V
-220V
User’s wiring
10A
10A
P2
AC2
P9
P1
P1: Connect with operation panel.
Power supply: AC 110V-220V ± 10% single
phase 50/60Hz
Power consumption: Max. 10 Watt
(Controller only)
Reading range: —45°C - 45°C ± 1°C
The output contact capacity show in the
wiring diagram. Do not overload.
If the compressor uses 220V, but the other
devices are 110V, connect their common
line to #G instead of #AC1
Before applying power to the unit,
always check if the voltage set correctly
according to the input voltage.