DVP-15MC Series Motion Controller Operation Manual
11-282
11
1
11.6.4.9
G50 (Precise Stop)
Function: Change the transition mode into precise stop. And the following transition modes are always
precise stop. G51/G52 can be used for the switch in the execution process. The terminal actuator will
reduce its speed to 0 between G codes.
Format: N_ G50
Parameter Explanation:
N_: The row number of G code in NC program
Example
N0 G50
N1 G1 X100 Y100
N2 G1 X300 Y100
100
0
300
100
Y
X