Chapter 8 Logic Instructions
8-41
8_
FB/FC
Explanation
Applicable model
FC
NE is used for a not-equal comparison of two variables or constants.
DVP15MC11T
DVP15MC11T-06
Parameters
Parameter
name
Meaning
Input/
Output
Description
Valid range
In1
Comparison
data
Input
A value to compare
Depends on the data type of the variable
that the input parameter is connected to.
In2
Comparison
data
Input
A value to compare
Depends on the data type of the variable
that the input parameter is connected to.
Out
Comparison
result
Output
Comparison result
Depends on the data type of the variable
that the output parameter is connected
to.
B
oo
le
an
Bit string
Integer
Real
number
Time, date
S
tr
in
g
B
OOL
BYT
E
WO
R
D
DW
O
RD
LW
O
R
D
US
INT
UI
NT
UDI
NT
UL
INT
SI
N
T
IN
T
DI
NT
LI
N
T
R
EA
L
L
R
E
AL
T
IME
D
AT
E
T
O
D
DT
S
T
RI
NG
In1
and
In2
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Out
●
Note:
The symbol
●
indicates that the parameter is allowed to connect to the variable or constant of the data
type.
Function Explanation
NE is used for a not-equal comparison of two variables and constants.
Out
is TRUE if
In1ǂIn2.
Otherwise,
Out
is FALSE.
The input parameters
In1
and
In2
are allowed to be the variables of different data types in this
instruction when the data types of input variables are not BOOL, TIME, DATE, TOD and STRING.
When the data type of one input variable is one of BOOL, TIME, DATE, TOD and STRING, input
parameters
In1
and
In2
are both required to be of the data type. For example, if the data type of
In1
is TIME, the data type of
In2
must be TIME. Otherwise, an error will occur in the compiling of the
software.
Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software
if any input variable is omitted. But the output variable is allowed to omit.
The data type of output variables must be BOOL. Otherwise, an error will occur during the
compiling of the software.
NE
EN
ENO
In1
Ou t
In2
Summary of Contents for DVP-15MC Series
Page 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Page 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Page 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Page 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Page 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Page 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Page 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Page 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Page 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Page 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Page 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...