background image

TECHNICAL DATASHEET

 

Sync DIN Rail Power Supply 

24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1NZ

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (July 2019, Rev. 04) 

 

1

 

 

Highlights & Features 

  Ultra compact size and galvanic isolation up to 3.0KVac 

between input to output and input to ground 

  Universal AC input voltage and full power from -10°C to 

+55°C operation 

  Up to 88.0% efficiency 

  Low earth leakage current < 1.0mA @ 264Vac 

  Extreme low temperature cold start at -40°C 

  NEC Class 2 / Limited Power Source (LPS) certified 

  Overvoltage / Overcurrent / Over Temperature Protections 

  Certified according to IEC/EN/UL 62368-1 

 

 

Safety Standards 

 

CB Certified for worldwide use 

 

 

Model Number:

   

DRS-24V30W1NZ 

Unit Weight:

 

 

0.11 kg (0.24 lb)  

Dimensions (L x W x D):

  75 x 21 x 89.5

 

mm

 

(2.95 x 0.83 x 3.52 inch) 

 

 

General Description 

The  ultra-compact and competitively priced Delta Sync DIN rail power supply series is designed for industrial applications requiring 

highly reliable power supply within a tight space. The Sync series operates with universal AC input range and offers full power up to 

55°C. The output is adjustable from 24-28 volts, and can support up to 3000 microfarads of load capacitance. A green LED indicates 

output is present. All models in the series are certified according to IEC/EN/UL 60950-1  Information Technology Equipment (ITE), 

IEC/EN/UL 62368-1  Audio/video, information and communication technology equipment  and UL 508 Industrial Control Equipment 

(ICE). The series is also fully compliant with RoHS Directive 2011/65/EU for environmental protection. NEC Class 2 and Limited Power 

Source (LPS) approvals are available for this product. 

 

 

Model Information 

Sync DIN Rail Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRS-24V30W1NZ

 

85-264Vac (120-375Vdc) 

24Vdc 

1.25A 

 

 

Model Numbering 

DR

 

S –

 

24V

 

30W

 

1

 

N

 

Z

 

DIN Rail 

Product Series 
S – Sync Series 

Output Voltage 

Output Power 

Single Phase 

NEC Class 2 

Without DC OK 

Relay Contact 

 

 

 

Summary of Contents for DRS-24V30W1NZ

Page 1: ...IN rail power supply series is designed for industrial applications requiring highly reliable power supply within a tight space The Sync series operates with universal AC input range and offers full p...

Page 2: ...test conditions for DC input Safety approval for DC input can be obtained upon request Output Ratings Characteristics Nominal Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc 2 Output Voltage A...

Page 3: ...ting Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 560 ft Shock Test Non Operating IEC60068 2 27 Half Sine Wave 50G for a duration of 11ms 3 times per direction 9 times in...

Page 4: ...s Safety Entry Low Voltage SELV EN 60950 Electrical Safety TUV Bauart EN 60950 1 EN 62368 1 UL cUL recognized UL 60950 1 UL 62368 1 CSA C22 2 No 60950 1 File No E191395 CB Scheme IEC 60950 1 IEC 62368...

Page 5: ...ia A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode3 2kV Differential Mode4 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fields IEC 61000 4 8...

Page 6: ...meters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com July 2019 Rev 04 6 Block Diagram Device Description 1 Input terminal block connector 2 Output terminal blo...

Page 7: ...Environment the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air temperature is lowered or the load is reduced as far as necessary...

Page 8: ...ottom Each device is delivered ready to install Mounting No output power de rating across the entire input voltage range Dismounting Fig 2 1 Mounting Snap on the DIN rail as shown in Fig 2 1 1 Tilt th...

Page 9: ...mm 0 39 inch to other units In case the adjacent device is a heat source the lateral distance will be 25mm 0 98 inch Note that the enclosure of the device can become very hot depending on the surround...

Page 10: ...to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is the...

Page 11: ...ernal feedback circuit fails The output voltage shall not exceed its specifications defined on Page 3 under Protections Power supply will latch off and require removal re application of input AC volta...

Page 12: ...at any line voltage from 85 264Vac and set the PSU 1 and PSU 2 output voltage Step 2 Connect the power supply units PSU 1 and PSU 2 to Vin 1 Vin 2 respectively of the DRR 20N or 20A module shown on th...

Page 13: ...tances in electrical and electronic equipment This product conforms to this standard Attention Delta provides all information in the datasheets on an AS IS basis and does not offer any kind of warrant...