(7) Basic Inspection
Item
Content
General Inspection
Periodically inspect the screws of the connection between the HMI and device.
Ensure the correct installation and the control panel
should be free from airborne
dust, harmful gases or liquids.
Inspection before
operation
(power is not applied)
Make sure that all wiring is correct to avoid damage and malfunction.
Visually check and ensure that no unused screws, metal strips, any conductive or
inflammable materials are inside the HMI.
Lower electromagnetic interference when devices are influenced by it.
Ensure that the external applied voltage to HMI is correct and matched to the
controller.
Inspection before
operation
(power is applied)
Check if power indicator lights up.
Check if the communication among devices is normal.
Please contact our local distributors or Delta sales representative if there are any
abnormal conditions.
(8) Specifications
Model
DOP-H07S42x
DOP-H07S46x
DOP-H07E42x
DOP-H07E46x
L
CD M
O
DU
L
E
Display
Type
7" TFT LCD (65535 colors)
Resolution
800 x 480 pixels
Backlight
LED Back Light (less than 20,000 hours half-life at 25
o
C)
(Note 1)
Display Size
154.08 x 85.92 mm
Operation
System
Delta Real Time OS
MCU
32-bit RISC Micro-controller
Flash ROM
Flash ROM 128 MB(OS System: 30 MB / Backup: 16 MB / User Application: 82 MB)
Backup Memory
(Bytes)
16 Mbytes ROM, 128 Kbytes SRAM
Buzzer
Multi-Tone Frequency (2K ~ 4K Hz)
/
85 dB
Ethernet
Interface
N/A
10/100 Mbps auto-sensing (with built-in isolated
power circuit)
(Note 2)
Serial COM Port
RS-422
/
RS-485
N/A
Memory Card
SD / SDHC
USB
1 USB Client Ver 2.0
Emergency Stop
A-contact: 1 / B-contact: 1
Rated voltage: DC 30V
Maximum rated current: 1A
Minimum allowable load: DC 5V/1 mA
Complies with IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, UL 508, and CSA C22.2
No.14, GB 14085.5
3-Position
Operation Switch
A-contact: 1
Rated voltage: DC 30V
Maximum rated current: 700 mA
Minimum allowable load
:
DC 3 V/5mA
Complies with EN/IEC60947-5-8, IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, and CSA
C22.2 NO. 14
Applicable standards for use with ISO12100-1, -2/EN12100-1, -2, IEC60204-1/EN60204-1,
ISO11161/prEN11161, ISO10218/EN775, ANSI/RIA R15.06, ANSI B11.19
Handwheel
N/A
Rated Voltage: <DC 24V
in
Resolution: 50(P/R)
Output Pulse: Square
Output Phase: A, B
Phase difference of A
and B: 90° ± 45°
Max. Frequency
response: 200 Hz
N/A
Rated Voltage: <DC
24V in
Resolution: 50(P/R)
Output Pulse: Square
Output Phase: A, B
Phase difference of A
and B: 90° ± 45°
Max. Frequency
response: 200 Hz
Function Key
15 Function Keys
Cable Length &
Type
End of Model Name: 5-5M, A-10M
Perpetual
Calendar
Built-in
Cooling Method
Natural cooling
Safety Approval
CE
(Note 3)
Waterproof Level
of Panel Display
N/A
Operation
Voltage
(
DC +24V (±15%) (with built-in isolated power circuit)
(Note 2)
Voltage
Endurance
AC500V for 1 minute (between charging (DC24V terminal)
and FG terminals)
Power
Consumption
5.6 W
(Note 4)
Backup Battery
3V lithium battery CR2450 × 1
Backup Battery
Life
About 5 years or more at 25
o
C but subjects to the temperature and the conditions during usage.
Operation
Temperature
0
o
C ~ 40
o
C
Storage
Temperature
-10
o
C ~ +60
o
C
Operating
Environment
10% ~ 90% RH
【
0 ~ 40
o
C
】
; 10% ~ 55% RH
【
41 ~ 50
o
C
】
; Pollution Degree 2
Vibration
Conforms to IEC61131-2;
Continuous: 5Hz ~ 8.3Hz 3.5 mm, 8.3Hz ~ 150Hz 1G
Shock
Conforms to IEC60068-2-27;
11ms, 15G Peak , X, Y, Z direction for 6 times
Dimension
257.4 x 170.3 x 71.8 (Emergency stop switch and hook
are included.)
(W) x (H) x (D)
mm
Weight
750 g (cable excluded)
NOTE
1)
The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25
o
C normal temperature and
humidity conditions.
2)
The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute.
3)
Some models are in the process of application to certification. For more information, please consult our distributors.
4)
Power consumption of HMI is the power consumed when not connecting to any peripheral devices. The power
supply of which capacity is 1.5 ~ 2 times the power consumption is recommended to ensure normal operation.
5)
DOPSoft , the program editor for DOP-H series products and user manuals can be downloaded at our website,
http://www.delta.com.tw/ia.
6)
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the latest version 7)
Isolated power supply is recommended.