background image

(7) Basic Inspection 

Item 

Content 

General Inspection 

  Periodically inspect the screws of the connection between the HMI and device.   

  Ensure the correct installation and the control panel

 

should be free from airborne 

dust, harmful gases or liquids. 

Inspection before 

operation 

(power is not applied) 

  Make sure that all wiring is correct to avoid damage and malfunction. 

  Visually check and ensure that no unused screws, metal strips, any conductive or 

inflammable materials are inside the HMI. 

  Lower electromagnetic interference when devices are influenced by it. 

  Ensure that the external applied voltage to HMI is correct and matched to the 

controller. 

Inspection before 

operation 

(power is applied) 

  Check if power indicator lights up. 

  Check if the communication among devices is normal. 

  Please contact our local distributors or Delta sales representative if there are any 

abnormal conditions. 

 
(8) Specifications 

Model 

DOP-H07S42x 

DOP-H07S46x 

DOP-H07E42x 

DOP-H07E46x 

L

CD M

O

DU

L

E

 

Display 

Type 

7" TFT LCD (65535 colors) 

Resolution 

800 x 480 pixels 

Backlight 

LED Back Light (less than 20,000 hours half-life at 25

o

C) 

(Note 1)

 

Display Size 

154.08 x 85.92 mm 

Operation 

System 

Delta Real Time OS 

MCU 

32-bit RISC Micro-controller 

Flash ROM 

Flash ROM 128 MB(OS System: 30 MB / Backup: 16 MB / User Application: 82 MB) 

Backup Memory 

(Bytes) 

16 Mbytes ROM, 128 Kbytes SRAM 

Buzzer 

Multi-Tone Frequency (2K ~ 4K Hz)

85 dB   

Ethernet 

Interface 

N/A 

10/100 Mbps auto-sensing (with built-in isolated 

power circuit) 

(Note 2)

 

Serial COM Port 

RS-422

RS-485 

N/A 

Memory Card 

SD / SDHC 

USB 

1 USB Client Ver 2.0 

Emergency Stop   

A-contact: 1 / B-contact: 1 

Rated voltage: DC 30V 

Maximum rated current: 1A 

Minimum allowable load: DC 5V/1 mA 

Complies with IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, UL 508, and CSA C22.2 

No.14, GB 14085.5 

  3-Position 

Operation Switch 

A-contact: 1 

Rated voltage: DC 30V 

Maximum rated current: 700 mA 

Minimum allowable load

DC 3 V/5mA 

Complies with EN/IEC60947-5-8, IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, and CSA 

C22.2 NO. 14 

Applicable standards for use with ISO12100-1, -2/EN12100-1, -2, IEC60204-1/EN60204-1, 

ISO11161/prEN11161, ISO10218/EN775, ANSI/RIA R15.06, ANSI B11.19 

Handwheel 

N/A 

Rated Voltage: <DC 24V 

in 

Resolution: 50(P/R) 

Output Pulse: Square 

Output Phase: A, B 

Phase difference of A 

and B: 90° ± 45° 

Max. Frequency 

response: 200 Hz 

N/A 

Rated Voltage: <DC 

24V in 

Resolution: 50(P/R) 

Output Pulse: Square 

Output Phase: A, B 

Phase difference of A 

and B: 90° ± 45° 

Max. Frequency 

response: 200 Hz 

Function Key 

15 Function Keys 

Cable Length & 

Type 

End of Model Name: 5-5M, A-10M 

Perpetual 

Calendar 

Built-in 

Cooling Method 

Natural cooling 

Safety Approval 

CE 

(Note 3)

 

Waterproof Level 

of Panel Display 

N/A 

Operation 

Voltage

 (

 

DC +24V (±15%) (with built-in isolated power circuit)

(Note 2)

 

Voltage 

Endurance 

AC500V for 1 minute (between charging (DC24V terminal)   

and FG terminals) 

Power 

Consumption 

5.6 W 

(Note 4)

 

Backup Battery 

3V lithium battery CR2450 × 1 

Backup Battery 

Life 

About 5 years or more at 25

o

C but subjects to the temperature and the conditions during usage. 

Operation 

Temperature 

0

o

C ~ 40

o

Storage 

Temperature 

-10

o

C ~ +60

o

Operating 

Environment 

10% ~ 90% RH

0 ~ 40

o

C

; 10% ~ 55% RH

41 ~ 50

o

C

; Pollution Degree 2 

Vibration   

Conforms to IEC61131-2;

   

Continuous: 5Hz ~ 8.3Hz 3.5 mm, 8.3Hz ~ 150Hz 1G 

Shock 

Conforms to IEC60068-2-27;   

11ms, 15G Peak , X, Y, Z direction for 6 times 

Dimension 

257.4 x 170.3 x 71.8 (Emergency stop switch and hook

 

are included.) 

(W) x (H) x (D) 

mm 

Weight 

750 g (cable excluded) 

 

 

NOTE

 

1) 

The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current 
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25

o

C normal temperature and 

humidity conditions. 

2) 

The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute. 

3) 

Some models are in the process of application to certification. For more information, please consult our distributors.   

4) 

Power consumption of HMI is the power consumed when not connecting to any peripheral devices. The power 
supply of which capacity is 1.5 ~ 2 times the power consumption is recommended to ensure normal operation.   

5) 

DOPSoft , the program editor for DOP-H series products and user manuals can be downloaded at our website, 
http://www.delta.com.tw/ia. 

6) 

The content of this instruction sheet may be revised without prior notice. Please consult our distributors or 
download the latest version 7) 

Isolated power supply is recommended.   

 