background image

 

 

DOP-

103SQ

 

High color 

  Wide screen 

   

User-friendly 

Delta Electronics, Inc. 

No.18, Xinglong Rd., Taoyuan City 

33068, Taiwan 

Instruction Sheet

 

(1) General precautions

 

Thank you for purchasing this product. This DOP-103SQ instruction sheet provides information for the 
DOP-103SQ series HMI. Before using this product, read the instruction sheet to ensure the correct use 
of the product. Keep this sheet handy for quick reference whenever needed. Before finishing reading this 
sheet, follow these instructions: 

 

Install the product in an indoor environment which is free of vapor and corrosive and inflammable 
gas. 

 

Refer to the wiring diagram when connecting the wires. 

 

Ensure this product is correctly grounded. The grounding method must comply with the national 
electrical standard guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.). 

 

Do not disassemble the HMI or change the wiring when the power is on. 

 

Do not touch the power supply when the power is on to avoid electric shock. 

 

When the HMI displays a low power notification and requires a battery change, contact our local 
distributor or Delta Customer Service Center for the replacement. Do not change the batteries by 
yourself. 

 

This product can be used with other industrial automation equipment. Read this sheet carefully 
and install the product according to the instructions to avoid danger. 

 

Cleaning method: use a dry cloth to clean the product. 

 

This product must be used at an altitude below 2,000 m (6561.68 ft). 

 

If the equipment is used in a manner not specified by the manufacturer, the protection provided 
by the equipment may be impaired.

 

 

For repair and maintenance, contact Delta Electronics, Inc. Address: No.18, Xinglong Rd., 
Taoyuan City, Taiwan. TEL: +886-3-3626301. 

If you have any inquiry during operation, contact our local distributors or Delta Customer Service Center. 
The instruction sheet may be revised without prior notice. Contact our distributors or download the latest 
version from Delta’s website at http://www.deltaww.com. 

(1)  Précautions générales (FR)

 

Merci d'avoir acheté ce produit. Cette fiche d'instructions fournit des informations pour les IHM de la 
série DOP-103SQ. Avant d'utiliser ce produit, lisez attentivement cette fiche d'instructions pour assurer 
une utilisation correcte du produit. Gardez cette fiche à portée de main pour pouvoir vous y référer 
rapidement en cas de besoin. Avant de terminer la lecture de cette fiche, suivez ces instructions : 

 

Installez le produit dans un environnement exempt de vapeur, de gaz corrosifs et de gaz 
inflammables. 

 

Reportez-vous au schéma de câblage pour le raccordement des fils. 

 

Assurez-vous que ce produit est correctement mis à la terre. La méthode de mise à la terre doit 
être conforme aux directives des normes électriques nationales (voir NFPA 70 : National 
Electrical Code (Code électrique national), 2005 Ed.). 

 

Ne démontez pas l’IHM et ne changez pas le câblage, lorsque l'appareil est sous tension. 

 

Ne touchez pas à l'alimentation électrique lorsque l'appareil est sous tension, cela pourrait 
provoquer un choc électrique. 

 

Lorsque l’IHM affiche une information d’alimentation faible et nécessite un changement de 
batterie, contactez votre distributeur local ou le centre de service clientèle Delta pour le 
remplacement. Ne changez pas vous-même les batteries. 

 

Ce produit peut être utilisé avec d'autres équipements d'automatisation industrielle. Lisez 
attentivement cette fiche et installez le produit conformément aux instructions pour éviter tout 
danger. 

 

Méthode de nettoyage : nettoyez le produit à l'aide d'un chiffon sec. 

 

Utiliser ce produit à une altitude inférieure à 2 000 m (6,561.68 ft). 

 

Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la protection fournie par 
l'équipement risque d'être compromise. 

 

Pour les réparations et l'entretien, contactez Delta Electronics, Inc. Adresse : No. 18, Xinglong 
Rd., Taoyuan City, Taiwan. TÉL : +886-3-3626301. 

Si vous avez des questions concernant le fonctionnement du programme, contactez nos distributeurs 
locaux ou le centre de service clientèle Delta. La fiche d'instructions peut être révisée sans préavis. 
Contactez nos distributeurs ou téléchargez la dernière version sur le site web de Delta à l'adresse 
https://www.deltaww.com/.

 

 
 
 
 
 
 

(2) Communication port pin assignment 

DOP-103SQ COM definition 

COM Port 

Pin 

MODE1 

MODE2 

MODE3 

COM1 

COM2 

COM1 

COM2 

COM1 

COM2 

RS-232

RS-485

RS-485

RS-485

RS-232

RS-422

D+ 

TXD+ 

RXD 

RXD 

TXD 

TXD 

D+ 

D+ 

RXD+ 

GND 

GND 

GND 

D- 

TXD- 

RTS 

RTS 

CTS 

CTS 

D- 

D- 

RXD- 

Note: the mark “-” means connection is not required.   

(3) Description of each part 

DOP-103SQ (front view) 

 

A

Operation / display area 

DOP-103SQ (rear view) 

 

A

USB slave 

B

USB host 

C

Power input port

 

(24 AWG wire min.)

D

COM1 

 
 
 
 
 
 
 
 
 
 

(4) Mounting dimensions 

DOP-103SQ 

Note: T = 1.6 mm - 3 mm (0.063" - 0.12")

Unit: mm (inches)

 

(5) Installation and wiring 

Precautions: 

 

Incorrect installation direction may result in malfunction. 

 

For better ventilation and cooling, allow sufficient clearance between the HMI and the adjacent 
objects or walls, or overheating may result in machine malfunction. 

 

This product should be used on Type 4X enclosures constructed for indoor use. 

 

The maximum panel thickness for mounting must be no greater than 5 mm (0.2 inches). 

 

Use copper wires. 

(5)  Installation et câblage (FR) 

Précautions : 

 

Un sens d'installation incorrect peut entraîner un dysfonctionnement. 

 

Pour une bonne ventilation et un refroidissement optimal, laissez un espace suffisant entre l'IHM et 
les objets ou les parois adjacentes, une surchauffe peut entraîner un dysfonctionnement de 
l’appareil. 

 

Ce produit doit être utilisé sur des boîtiers de type 4X fabriqués pour une utilisation en intérieur. 

 

L'épaisseur maximale du panneau pour le montage ne doit pas dépasser 5 mm (0,2 pouce). 

 

Utilisez des fils de cuivre. 

Installation diagrams: 

Step 1: 
Apply the waterproof gasket to the HMI and then 
insert the HMI into the panel cutout. 

Step 2: 
Place the fasteners into the slots and tighten the 
screws until reaching the panel cutouts. 

 

Step 3: 
Tighten the screws with the torque of 0.5 N-m or   
0.7 N-m. Do not apply a torque greater than the 
specified torque, or the plastic case will be 
damaged. 
The mounting torque for DOP-103SQ is 4.41 lb-inch 
(0.5 N-m). 

Step 4: 
For heat dissipation, keep a minimum clearance of 
60 mm (2.36 inches) and 45 mm (1.77 inches) 
respectively on the rear and bottom of the HMI. 

 

 

Summary of Contents for DOP-103SQ

Page 1: ...IHM affiche une information d alimentation faible et n cessite un changement de batterie contactez votre distributeur local ou le centre de service client le Delta pour le remplacement Ne changez pas...

Page 2: ...wer consumption 2 5 67 W Max 3 Backup battery 3V lithium battery CR2032 1 Backup battery life About 3 years or more at room temperature of 25 C 77 F subject to operating temperature and condition Oper...

Page 3: ...herhangi bir bildirime gerek duyulmadan de i tirilebilir Dok man n son versiyonunu internetten indirebilirsiniz http www deltaww com 2 Haberle me Pinleri DOP 103SQ COM port COM Port Pin MOD 1 MOD 2 M...

Page 4: ...lityum pil CR2032 1 Yedekleme Pil mr Normal ko ullarda 25 C de 3 y l veya daha fazla al ma S cakl 0 C 50 C 32 F 122 F Depolama S cakl 20 C 60 C 4 F 140 F al ma Ortam 10 90 RH 0 C 40 C 10 55 RH 41 C 5...

Page 5: ...OM1 COM2 COM1 COM2 COM1 COM2 RS 232 RS 485 RS 485 RS 485 RS 232 RS 422 1 D TXD 2 RXD RXD 3 TXD TXD 4 D D RXD 5 GND GND GND 6 D TXD 7 RTS RTS 8 CTS CTS 9 D D RXD 3 DOP 103SQ A DOP 103SQ A USB Slave B U...

Page 6: ...422 RS 485 2 COM3 N A N A CE UL shielding 300 ohm 100 MHz IP65 NEMA4 UL TYPE 4X 2 DC 24V 15 15 Supplied by Class 2 or SELV circuit isolated from MAINS by double insulation DC24V FG AC500V 1 2 5 67 W...

Page 7: ...COM1 COM2 COM1 COM2 RS 232 RS 485 RS 485 RS 485 RS 232 RS 422 1 D TXD 2 RXD RXD 3 TXD TXD 4 D D RXD 5 GND GND GND 6 D TXD 7 RTS RTS 8 CTS CTS 9 D D RXD 3 DOP 103SQ A DOP 103SQ A USB Slave B USB Host...

Page 8: ...mm 8 3 Hz 150 Hz 1G IEC60068 2 27 11 ms 15G Peak X Y Z 6 W x H x D mm 129 x 103 x 37 8 W x H mm 118 8 x 92 8 280g 1 25 C 2 1 1500V 3 1 5 2 4 5 DOP 100 DOPSoft http www deltaww com 6 DOP 100 Part Name...