background image

11- ENG

D29382

BEFORE STARTING

1.

Move pressure washer to level ground.

2.

Make sure the ON/OFF switch is in the OFF position

To reduce the risk of electrocution, keep all connections dry
and off the ground. Do not touch plug with wet hands. Do not

use if cord is damaged.

3.

Plug the unit into an appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances. See the 

GROUNDING

paragraph. 

4.

Press reset button and indicator light (a) will appear. You will have one of the
following GFCI switches shown below.

5.

Test GFCI switch before each use, to test:
a.

Press test button (b), indicator light will disappear.

c.

Press reset button (c) to use unit. If indicator light does not reappear DO
NOT use unit, see troubleshooting guide.

READ AND UNDERSTAND ALL WARNINGS BEFORE STARTING UNIT

When using the high pressure setting, DO NOT

allow the

high pressure spray to come in contact with unprotected skin,

eyes, or with any pets or animals. Serious injury can occur.

Your washer operates at fluid pressures and velocities high enough to penetrate
human and animal flesh, which could result in amputation or other serious injury.
Leaks caused by loose fittings or worn or damaged hoses can result in injection
injuries. 

DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT! See a

physician immediately!

Never

pull water supply hose to move pressure washer. This

could damage hose and/or pump inlet.

DO NOT 

use hot water, use cold water only.

Never

turn water supply off while pressure washer motor is running or damage

to pump will result.

This unit is equipped

with an automatic stop mode. When the trigger is released

the motor is shut off automatically. When the trigger is pressed again the motor
will automatically start. The time between release and engagement must not be
less than 4-5 seconds. 

DO NOT

leave the unit in automatic stop mode for more

than 15 minutes.

Stand on a stable surface

and grip gun/wand firmly with both hands. Expect

the gun to kick when triggered.

This product is intended for intermittent use only

. Operate pressure washer

one hour or less in a 2 hour period. 

If you do not understand these precautions please call 1-866-422-4286 to
speak to a service representative for further instructions.

a

c

b

c

b

a

c

b

a

Summary of Contents for D29382

Page 1: ...ore about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Electric Pressure Washer with 2400 Cleaning Units Model...

Page 2: ...Instructions Do not use with extension cords SAFETY GUIDELINES DEFINITIONS Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potential...

Page 3: ...ause injury or death Restricting any of the pressure washer ventilation openings will cause serious overheating and could cause fire Never place objects against or on top of pressure washer Operate pr...

Page 4: ...ed while unit is running Know how to stop product and bleed pressure quickly Pressure washer pump contains moving parts Contact with moving parts can cause serious injury Never operate machine with pu...

Page 5: ...e plug provided with the product if it will not fit the outlet have a proper outlet installed by a qualified electrician Do not use any type of adapter with this product EXTENSION CORDS Use additional...

Page 6: ...e conveniently located and equipped to handle all in warranty and out of warranty service For the location of the nearest Authorized Warranty Service Center call 1 866 422 4286 24 hours a day 7 days a...

Page 7: ...7 ENG D29382 ASSEMBLY INSTRUCTIONS 2 Connect spray wand to gun Tighten securely 3 Attach high pressure hose to gun Tighten securely 1 Place handle assembly onto frame and connect handle to frame...

Page 8: ...ning solutions see How To Use Cleaning Solution Application Unit in this section READ THIS OWNER S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustrations with your unit to famili...

Page 9: ...change from narrow jet stream to fan jet as shown Total Stop System This unit is equipped with a total stop system When the trigger is released the motor is shut off automatically When the trigger is...

Page 10: ...m cleaning solution application nozzle b Position the notch c on the pipe to the desired soap mixture 1 6 1 being the highest and 6 being the lowest c Press pipe into position 6 Fill application tank...

Page 11: ...sures and velocities high enough to penetrate human and animal flesh which could result in amputation or other serious injury Leaks caused by loose fittings or worn or damaged hoses can result in inje...

Page 12: ...ckwise until it snaps into place To remove nozzle turn nozzle counter clockwise to remove To connect chemical application unit c see How To Use Cleaning Solution Application Unit in this section 12 Tu...

Page 13: ...detergent apply the high pressure jet keeping the nozzle at least 10 inches from the surface work from the bottom up SHUTTING DOWN YOUR PRESSURE WASHER 1 Place the ON OFF switch in the OFF position 2...

Page 14: ...ction is removed 6 Direct water supply into nozzle end to backflush loosened particles for 30 seconds 7 Plug unit into appropriate outlet 8 Reassemble the nozzle to the wand Tighten securely to preven...

Page 15: ...FOR MORE THAN 30 DAYS AND OR WHEN FREEZING TEMPERATURES ARE EXPECTED RV antifreeze needs to be run through the pump as outlined in the steps below 4 Obtain a funnel six ounces of RV antifreeze and app...

Page 16: ...rce circuit continues to trip or blow fuses Motor hums but will not start Worn nozzle Replace nozzle Pressure fluctuates with out opening gun Water leak in high pressure fittings hose or gun Replace h...

Page 17: ...17 ENG D29382...

Page 18: ...with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Delta Authorized Warranty Service Center that provides on site service calls for service call arrangement...