Timer + Counter Function
In Timer + Counter function, SV1, PV1 and Output 1 are for Timer; SV2, PV2 and Output2 are for Counter. DIP switch is
disabled. All timer and counter functions remain except
y
RCY2, SCON, STON, STOFF in output mode of Timer function
y
Command up/down, Individual up/down, quadrature counting in input mode, S, T, D in output mode of Counter function
Only 1-stage counting in Counter function is available.
Easy DIP Switch Setup
Users can use DIP switch to setup parameters. When DIP is switched to ON, the corresponding parameters can only be
read, not changed.
SW
Counter
Timer
Tachometer
8
Reset pulse width
ON: 1ms, OFF: 20ms
Reset pulse width
ON: 1ms, OFF: 20ms
Reset pulse width
ON: 1ms, OFF: 20ms
7
Input type
ON: PNP OFF: NPN
Unit of Timer
See Table 2
Input type
ON: PNP OFF: NPN
6 N/A
Unit of Timer
See Table 2
N/A
5
Counting speed
ON: 10KCPS OFF: 30CPS
Unit of Timer
See Table 2
Counting speed
ON: 10kHz OFF: 30Hz
4
Output mode of counter
See Table 3
Output mode of Timer
See Table 3
Output mode of Tachometer
See Table 3
3
Output mode of counter
See Table 3
Output mode of Timer
See Table 3
Output mode of Tachometer
See Table 3
2
Input mode of counter
ON: counting down OFF: counting up
Time counting up/down
ON: down OFF: up
N/A
1
ON: Enable DIP
OFF: Disable DIP
ON: Enable DIP
OFF: Disable DIP
ON: Enable DIP
OFF: Disable DIP
SW5
SW6
SW7
Displayed unit
OFF OFF OFF 0.01s
ON OFF OFF
0.1s
OFF ON OFF
1s
Output Mode Configuration
ON ON OFF
min,
0.01s
SW3
SW4
Counter
Timer
Tachometer
OFF
OFF
ON
min, 0.1s
OFF
OFF
F
Signal ON Delay 1
Lo-Lo
ON
OFF
ON
0.1 min
ON
OFF
N
Signal ON Delay 2
Lo-Hi
OFF
ON
ON
min
OFF
ON
C
Signal OFF Delay
Hi-Lo
ON
ON
ON
hr, min, sec
ON
ON
R
Signal ON
Hi-Hi
Table 2
Table 3
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.