20210721
Installation
Insert Rawlplug
Wiring
PF pipe(mm)
Conduit hole(mm)
Φ28
Φ34
Screw torque:
0.8 N·m
(8 kgf·cm)
Current Transformer installation
Installation of BX12.6_AC100
- Please do not install the battery
pack on uneven floor surfaces.
- Holes size is 16 mm diameter for
attaching the battery pack.
CAUTION !
1. Drill 4 holes with
Φ
16 mm diameter in dimension 540 mm x 220 mm
2. Insert Rawlplug into these hole
3. Put on and fix BX6.3_AC100 firmly
* Please do not remove all the rubber covers on BX6.3_AC100 if BX6.3_EX100
is not installed.
①
②
③
④
220 mm
540 mm
1. The CT can be opened.
2. Take the CT clip on the Line conductor wire.
3. please be aware of the CT direction.
Arrow symbol means utility grid.
4. Connect the CT wires to the device.
5. Connect CT wire to the CT port of
communication card.
L
N
Main
Breaker
Energy meter
of the electric
utility
company
CT label direction
Model
GENERAL
Enclosure
Operating temperature
Relative humidity
Galvanic isolation
Safety class
Type
Battery Module
Typical Energy
Typical Voltage
Voltage Range
BX6.3_AC100
BX12.6_AC100
Aluminum with powder coating
-10
℃ *
~ 45
℃
* 0 degree for the first time installation.
0% – 95% non-condensing.
Operating Altitude
0 to 2000m (0 to 6666 ft.)
NO
Environmental category
Indoor / Outdoor
Protection degree
IP65 (Electronics)
Pollution degree
PD 2
Overvoltage category
AC output :III
Class I metal enclosure with protective earth
Weight
Dimensions(W*H*D)
570 × 840 × 250 mm
570 × 840 × 250 mm
+ 520 × 600 × 230 mm
Connectors
Weather resistant connectors
Audible noise
< 40dB
Li-ion
Samsung SDI 41J (21700)
6.3 kWh
DC 202.7 V
DC 175 - 228 V
12.6 kWh
DC 405.4 V
DC 350 - 456 V
BT INPUT
77kg
77 kg (BX6.3_AC)
+ 60 kg (BX6.3_EX)
Voltage
On Grid Nominal current
Stand-Alone Nominal current
Inrush current
Maximum output fault current (rms)
Maximum overcurrent protection
Tare loss
Frequency
Total harmonic distortion
Power factor
Nominal power
3000 VA
Maximum power
3000 VA
4500 VA
4500 VA
19.6 A
19.6 A
According to country setting
(Programmable 230Vac ± 20%)
16 A / 100 us
13 A
13 A
25 A
25 A
25 A
25 A
> 0.99 @ full power
Rated 50/60 Hz (Programmable 45-65 Hz)
< 3 %
Active anti-islanding method
Reactive power injection
Output current DC component
< 0.5% rated current
< 10 W
Maximum efficiency
BT+
BT-
Ground
①
Uart signal
②
Relay signal
③
Heater signal
96.5%
AC INPUT / OUTPUT
SYSTEM INFORMATION / COMMUNICATION
User interface
External communication
Variations and flicker
Immunity
Electrical safety
Wi-Fi connection
365 days data logger and real time clock
30 events record
2 RS-485 connections
EN 61000-3-3
CE conformity
Yes
Grid interface
AS/NZS 4777.2 :2015
Emission
EN 61000-6-3
Harmonics
EN 61000-3-2
EN 61000-6-2
CS
Immunity
PFMF
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
ESD
RS
EFT
Surge
IEC 61000-4-6
IEC 61000-4-8
IEC 62619:2017, IEC 62040-1:2017
REGULATIONS & DIRECTIVES
① ② ③