Page 2.
MODEL GBR
80LED
2. DUCT CONNECTION
2-1.
Insert the duct (not provided) into the duct
connector and tape all ductworks connection
to make them secure and air tight.
2-2.
Install the duct with a gradient 1°~2° to the
outside.
Inside
Outside
Duct
Body
Gradient
1°~2°
Tape
Ceiling
Grille
Duct Connector
3. CONNECT WIRING
3-1. Follow all local electrical and ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached
from a tub or shower.
(BLUE)
LIGHT
(BLK)
FAN
WHT
WHT
BLU
BLK
LIGHT
SWITCH
FAN
SWITCH
BLK
WHT
GRD
LIGHT/FAN ELECTRICAL BOX
LINE
IN
HOUSE ELECTRICAL BOX
3-3. Connect wires as shown in wiring diagrams.
3-4. Use wire nuts (not provided) and connect
house power cable to ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor
that shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. Insert the LED lighting connecting into the
power socket of main body as below shown.
4-2. When the power on, check for abnormal
vibration or sound.
4-3. Insert the mounting springs into the slots and
mount the grille to the fan unit.
Grille
Spring
Slots
Lighting Connector
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF,
and LED indicator is green.
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit.
Routine maintenance must be done every year.
CAUTION:
1.
Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2.
Do not allow water to enter motor.
3.
Do not soak resin parts in water over 60°C.
CLEANING
:
1.
Pull down the spring to remove grille.
2.
Clean grille. (Use non-abrasive kitchen
detergent, wipe dry with new cloth.)
3.
Use a cloth dampened with non-abrasive
kitchen detergent, remove dust and dirt from
ventilating fan. Wipe dry with new cloth.
4.
Replace grille.
DIMENSIONS
10.7
5"
10
.75
"
5 .7 5 "
8"
8 .
2 5
"
4" DUCT
10.75"
10.75"
8.25"
5.75"
0.84"
SPECIFICATIONS-FAN
Model No. Voltage
(V)
Frequen
cy
(Hz)
Power
@ 0.1SP
(W)
Air Flow
@ 0.1SP
(CFM)
Weigh
t
(lb.)
Power
@
0.0SP
(W)
GBR80LED 120
60
11.6
80
6.1
10.0
Note: Design and specifications subject to change
without notice.
SPECIFICATIONS-LED LIGHT ENGINE
ITEM
SPEC.
DIMENSION
(
INCH
)
8L×4.4W×1.4H
POWER CONSUMPTION
(
W
)
11
CORRELATED COLOR
TEMPERATURE (K)
2700
LIGHT SOURCE LIFE
(
HOURS
)
30000
(
MIN.
)
TRANSIENT PROTECTION
CLASS A
OPERATING FREQUENCY
(
HZ
)
120
FCC QUALIFIED
YES
ENERGY QUALIFIED
YES
ROHS QUALIFIED
YES
SAFETY REQUIREMENTS
UL/cUL
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED
WARRANTY
Delta Electronics Inc. (“Delta Electronics”)
warrants to the original consumer purchaser in
the USA that the Breez ventilation fan products
will be free from defects in material or
workmanship. This warranty is limited to three (3)
years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for
any defective product will be supplied free of
charge for installation by the consumer. The
warranty provided herein does not cover
charges for labor or other costs incurred in the
troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must
include the product model number, and must
be made through an authorized Delta
Electronics distributor. Authorized returns must
be shipped prepaid. Repaired or replacement
products will be shipped by Delta Electronics
F.O.B. shipping point.
3. Delta Electronics shall not be liable for any
indirect, incidental, consequential, punitive, or
special damages arising out of or in connection
with products use or performance, regardless
of the form of action whether in contract, tort
(including negligence), strict product liability or
otherwise.
4. This warranty does not extend to fluorescent
lamp starters and tubes.
5. The warranty does not cover if user does not
comply with manufacture’s installation manual.
6. To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
7. Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation,
improper use, improper maintenance,
improper repair, improper alteration, improper
modification, tampering or accident of
products or parts thereof, or unusual
deterioration or degradation of products or
parts thereof due to a physical environment
beyond the requirements of products’
specifications.
Address:4405 Cushing Parkway, Fremont, CA
94538 US Toll Free Number: 1-888-979-9889
GlobalTowne ~ 888-726-9752
www.globaltowne.com