TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

The fan is not  

turning ON

1. 

Power off

2.  Faulty switch
3.  Faulty wire connection

1.  Make sure power supply is on.
2.  Test or replace switch.
3.  Check wire in switch box.

The fan seems louder than it should

1.  CFM too great
2.  Damper not working properly or damaged 

3.  Bend in duct too close to fan discharge 

4. 

Fan discharge reduced to fit smaller duct

5.  Fan body not securely attached

1.  Be sure the CFM rating on the fan matches the size of your room.
2.  Check damper to ensure it is opening and closing properly. If the damper has 

become damaged, please call Customer Service.

3.  Be sure you do not have any sharp bends in duct closer than 18 in. to the fan 

discharge.

4.  Use recommended size ducting to reduce fan noise.
5.  Be sure the fan is securely attached to your ceiling joists.

The fan is not clearing the room

1. 

Insufficient intake airfow within room

 

2. 

Insufficient CFM

1. 

Be sure a door or window is slightly ajar or opened to allow airflow. The fan is 

not able to draw air out of the room without enough airflow to draw in from.

2.  Be sure the CFM rating on the fan matches the requirements for your room 

size.

The light is not turning ON

1. 

Power off

2.  Faulty switch
3.  Faulty wire connection

1.  Make sure power supply is on.
2.  Test or replace switch.
3.  Check wire in switch box.

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free 
from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1.  During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty 

provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.

2.  All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics 

distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.

3.  Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with 

products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.

4. 

This warranty does not extend to fluorescent lamp starters and tubes.

5.  The warranty does not cover if user does not comply with manufacturer’s installation manual.
6.  To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7. 

Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper 

transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper 

alteration, improper modification, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts 
thereof due to a physical environment beyond the requirement of products' specifications.

Summary of Contents for breez REC80LED

Page 1: ... be reached from a tub or shower 10 Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Fig A Turning angle too large Too many elbows Duct shrink Elbow near the body Body Minimum 18 in CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 Not for use in cooking are...

Page 2: ...ON BLACK GREEN WHITE WHITE RED Dual Switch Control With dual switches the fan and light can be controlled independently FAN SWITCH JUNCTION BOX SWITCH BOX GRD L N M LED MODULE UNIT OFF ON BLACK GREEN WHITE WHITE RED LIGHT SWITCH L N OFF ON BLACK ON OFF SWITCH purchase separately SWITCH BOX 120 VAC LINE IN WHITE GROUND bare FAN WIRING PLATE RED Dual Switch Control With dual switches the fan and lig...

Page 3: ...leaner 3 4 Dampen cloth with dust detergent and wipe the fan body 1 Then wipe dry with a clean cloth 1 4 5 Replace LED module 2 back onto fan body 1 2 1 5 6 Turn on power source to operate fan again DIMENSIONS Unit Inches mm PRODUCT SPECIFICATIONS Model No Voltage V Frequency Hz Air Flow 0 1SP CFM Power 0 1SP W Max Current amps Weight lb Note LED light spec REC80LED 120 60 80 14 5 0 34 8 8 Single ...

Page 4: ... Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions 1 During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs ...

Reviews: