background image

 

 

 

 

 

 

MODELS:

 GBR50 / GBR80 

Page 1. 

INSTALLATION AND 
OPERATING INSTRUCTIONS 

VENTILATION FAN 

 

 

READ AND SAVE THESE 

INSTRUCTIONS 

 

GENERAL SAFETY INFORMATION 

1.

 

Make sure that the electric service supply voltage is 
AC 120V, 60Hz. 

2.

 

Follow all local electrical and safety codes, as well as 
the Nation Electrical Code (NEC) and the Occupation 
Safety and Healthy Act (OSH Act). 

3.

 

Always disconnect the power source before working 
on or near the ventilating fan, motor or junction box. 

4.

 

Protect the power cord from sharp edges, oil, grease, 
hot surfaces, chemicals or other objects. 

5.

 

Do not kink the power cord. 

6.

 

Do not install the unit where ducts are configured as 
shown in Fig. A. 

7.

 

Provide suction parts with proper ventilation. 

8.

 

This unit is UL listed for use over a bathtub or shower 
when installed in a GFCI protected branch circuit. 

9.

 

These ventilating fans are intended for residential 
usage only. 

 

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.

 

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer. 

2.

 

Before servicing or cleaning unit, switch power off at 
service panel and lock the service disconnecting 
means to prevent power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

3.

 

Installation work and electrical wiring must be done 
by qualified person(s) in accordance with all 
applicable codes and standards, including fire-rated 
construction. 

4.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of 
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s 

guideline and safety standards such as those 
published by the National Fire Protection Association 
(NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers 
(ASHRAE) and the local code authorities. 

5.

 

When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities. 

6.

 

Ducted fans must always be vented to the outdoors. 

7.

 

If this unit is to be installed over a tub or shower, it 
must be marked as appropriate for the application 
and be connected to a GFCI (Ground Fault Circuit 
Interrupter)   

-protected branch circuit.

8.

 

Do not use this unit with any other solid-state 
control devices. Solid-state control devices may 
cause harmonic distortion, which can cause a motor 
humming noise. 

9.

 

NEVER

 place a switch where it can be reached from 

a tub or shower. 

10.

 

Not to be installed in a ceiling thermally insulated to 
a value greater than R40. (This is required for 
installation in Canada only). 

 

CAUTION

 

1.

 

For general ventilating use only. Do not use to 
exhaust hazardous or explosive materials and vapors. 

2.

 

Not for use in cooking areas. (Fig. B) 

3.

 

This product must properly connect to the 
grounding conductor of the supply circuit. 

4.

 

To reduce the risk of injury to persons, install the fan 
at least 7 feet (2.1m) above the floor. 

SUPPLIED ACCESSORIES 

Part name 

Appearance 

Quantity 

Grille 

 

Fan 

 

Housing 

 

Duct 

Connector 

(4”) 

 

Screw 

(

Ø

4×25) 

 

 

 

 

 

 

 

 
1. INSTALLATIONS 

MOUNT HOUSING WITH FLANGE: 

1-1.

 

To bend the housing tabs out to 90 degree and 
make housing tabs contact the bottom of the joist. 

Tabs

Joist

 

1-2.

 

The housing mounts with 4 screws (

Ø

4×25). Screw 

housing to joist through lowest holes in each 
mounting flange, then through the other holes. 

Screw 

Joist

 

USING SUSPENSION BRACKETS (SOLD SEPARATELY) 

1-3.

 

Sliding suspension brackets available to allow for 
your specific positioning of housing anywhere 
between joists and span up to 24”. 

1-4.

 

Insert suspension brackets into the channels on 
housing. Make sure tabs face “up” shown. 

Channel

Suspension Bracket

(Sold separately)

Tab Face

 

1-5.

 

Extend suspension brackets to the width of the joists. 
Hold fan in place with the suspension brackets tabs 
wrapping around the bottom of joist. 

1-6.

 

Fasten suspension brackets to joists with nails or 
screws through holes near nails. 

1-7.

 

Secure suspension brackets together with screws. 

Joist

Joist

Bottom of Joist

Screw

 

 

Fig. A 

Fig. B 

 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

45°

Cooking area

45°

Do not install above or

  inside this area

 Cooking

Equipment

floor