Wiring
3-57
3
3.10.5 Wiring for STO
3.10.5.1 Not using the STO function
You can short-circuit the connector or plug in the short-circuit connector that comes with the
servo drive.
2
3
4
5
6
7
8
STO_A
/ STO_A
STO_B
/ STO_B
FDBK+
FDBK-
Reserved
STO
1
Reserved
M
3.10.5.2 Single drive module
To use a safety relay to trigger the STO function, connect the wiring as shown in the following
diagram:
ESTOP
2
3
4
5
6
7
8
STO_A
/ STO_A
STO_B
/ STO_B
FDBK+
FDBK-
Reserved
STO
24V DC
Safety
relay
1
Reserved
M