6.3.4
Scaling of the analog command
In Analog mode, you control the motor’s Speed command by the analog voltage difference
between V_REF and VGND. Use parameter P1.040 (maximum rotation speed for the analog
Speed command) to adjust the slope of the speed change and its range.
6000 rpm
3000 rpm
6000 rpm
3000 rpm
Slope is set by
P1.040
Analog voltage input (V)
10
5
-10
-5
Relevant parameters: refer to Chapter 8 for more information.
Parameter
Function
P1.040
Maximum rotation speed for the analog Speed command