background image

www.delta-dct.com

Wired Controller 29FWC-100E

INSTRUCTION MANUAL

WARNING! 

Read and follow all safety precautions in

Instruction Manual - improper use can cause

serious injury.

Summary of Contents for 29FWC-100E

Page 1: ...www delta dct com Wired Controller 29FWC 100E INSTRUCTION MANUAL WARNING Read and follow all safety precautions in Instruction Manual improper use can cause serious injury...

Page 2: ...personal harm to the user or damage to property CAUTION 1 Do not install the wired controller in the damp place or under direct sunlight 2 Do not beat toss or frequently assemble disassemble the wired...

Page 3: ...Buttons 4 3 OPERATION INSTRUCTION 5 3 1 On off 5 3 2 Mode Setting 5 3 3 Temperature Setting 6 3 4 Fan Speed Setting 6 3 5 Right and Left Swing 7 3 6 Up and Down Swing 8 3 7 Timer Setting 8 3 8 Air Ex...

Page 4: ...tion Setting 21 3 19 Ultra Dry Setting 22 3 20 Other Functions 22 4 Installation of the Wired Controller 24 4 1 Standard Parts 24 4 2 Installation Location and Installation Requirements 25 4 3 How to...

Page 5: ...1 1 Introduction to the Wired Controller Fig 1 Appearance of the Wired Controller 1 1 Appearance and LCD Icons Fig 2 Appearance of the LCD...

Page 6: ...T mode 10 Health function 11 I Demand function 12 Vacation function 13 Status display of master and slave wired controller 14 Shield function The button operation temperature setting On Off operation...

Page 7: ...3 20 Electric heater 21 Blow function 22 Defrosting function 23 Filter cleaning 24 Timer Setting 25 Keycard control Detected status sensed by human body 26 Quiet function 27 Lock function...

Page 8: ...SAVE E HEATER BLOW QUIET 7 Timer Timer setting 8 On Off Turn on off indoor unit 4 mode and 2 Memory Press Mode and at the same time for 5s under the OFF state of the unit to activate deactivate memory...

Page 9: ...state of the unit after energization The state shown in Fig 5 indicates the ON state of the unit after energization Fig 4 OFF State of the Unit Fig 5 ON State of the Unit 3 2 Mode Setting Under the ON...

Page 10: ...decreased by 1 C every 0 5s In Cooling Dry Fan and Heating mode temperature setting range is 16 C 30 C In Auto mode the setting temperature is un adjustable As shown in Fig 7 Fig 7 Temperature Settin...

Page 11: ...t the Right and Left Swing function option and then press the Enter Cancel button to deactivate it Right and Left Swing function setting is as shown in Fig 9 Unit On no left right swing Press Function...

Page 12: ...to start the unit When the unit is OFF press the Timer button with xx Hour displayed and ON blinking then press to adjust the timer after that press the Timer button again to make a confirmation If t...

Page 13: ...hr every 0 5s Notes When Timer On and Timer Off both are set the displayed time is the Timer On setting for the unit under the OFF state or is the timer Off setting for the unit under the ON state Tim...

Page 14: ...and fresh air valve runs for 48 min 9 The unit continuously runs for 60min and fresh air valve runs for 54 min 10 The unit continuously runs for 60min and fresh air valve always runs How to deactivate...

Page 15: ...on button to set sleep function Press Enter Cancel button to activate sleep function Press Function button to set sleep function Press Enter Cancel button to cancel sleep function Fig 13 Sleep Setting...

Page 16: ...hour Fig 14 Sleep Curve under the COOL Mode Under the Heat mode the Sleep function is ON the setting temperature range can be 16 C 17 20 C 21 27 C or 28 30 C Each of them has a different curve as sho...

Page 17: ...tion Press Enter Cancel button to cancel health function Press Function button to set health function Fig 16 Health Setting Note The health function can be cancelled by turning off the unit The health...

Page 18: ...et the unit will run as per Auto fan speed The Turbo fan speed is not available When the I Demand function is set the setting temperature 27 C can not be changed When the setting temperature is shield...

Page 19: ...ation function can not be set when the distant shielding is taking into effect When the vacation function is set the setting temperature shown on the wired controller is 8 C The indoor fan will automa...

Page 20: ...be used to adjust Turbo function 3 14 SAVE Function Setting Energy Saving Function Energy saving can make the air conditioner runs in a smaller temperature range by setting lower limited value of sett...

Page 21: ...Setting Notes Under the Auto mode when the SAVE function is activated the unit will forcibly quit the Auto mode and change to the current operation mode Further the Sleep function will be deactivated...

Page 22: ...and then press the Enter Cancel button to deactivate it E HEATER Function setting is as shown in Fig 21 Unit On no E heater function Press Function button to set E heater function Press Enter Cancel...

Page 23: ...On Off button the indoor fan will still run at low fan speed for another 10 minutes When the Blow function is deactivated the indoor fan will stop directly as the unit is turned off The Blow function...

Page 24: ...number represents the pollution level The second number shows the accumulated operating time of the indoor fan There are four statuses in total No Filter function setting 00 shown at the timer area W...

Page 25: ...set the icon will light up If it is not necessary to clean the filter no matter whether the setting is changed or not the unit will not restart to timing while pressing Enter Cancel button If the filt...

Page 26: ...e setting temperature is 16 C press button twice and the setting temperature will be changed to 12 C at this time the unit enters the Ultra Dry function When the Ultra Dry function is activated it can...

Page 27: ...is no operation in 20s the unit will quit from this function automatically Note If the unit is not connected with the ambient temperature sensor after 12h electrification the display of the ambient t...

Page 28: ...nterface Fig 25 Indoor fan shutdown mode setting Note In the parameter setting interface only when 05 shown on it the indoor fan shutdown mode can be set Other parameters are not allowed to be modifie...

Page 29: ...e the communication line is wired into the correct port otherwise it would result in communication fault The communication line wired controller and power line must be separated with the minimal dista...

Page 30: ...ircuit potential Set the panel and the bottom together by clasps 4 4 How to Remove the Wired Controller The wired controller can be easily removed as shown in Fig 28 Fig 28 Removal of the Wired Contro...

Page 31: ...ent temperature sensor error 12 F4 Discharge temperature sensor error 13 F5 Temperature sensor error of wired controller 14 C5 Capacity code error 15 EE Outdoor memory chip error 16 PF Electric box se...

Page 32: ...35 PA AC current protection 36 Pc Drive current error 37 Pd Sensor connecting protection 38 PE Temperature drift protection 39 PL Bus low voltage protection 40 PH Bus high voltage protection 41 PU Cha...

Page 33: ...Thank you for Choosing airconditioners Perfectly engineered for your comfort www delta dct com...