background image

You can have your drill press converted to 230 volt
operation.

A qualified electrician must perform this conversion. Should
you desire to have your drill press converted for 230 volt
operation, take your drill press to your local Authorized
Delta Service Center. You can call 800-223-7278 for the
location of the nearest Authorized Service Center.

When converted for 230 volt operation, your drill press is
intended for use on a circuit that has an outlet like the one
illustrated in Fig. C. After conversion to 230 volts, the drill
press will have a grounding plug that looks like the plug
illustrated in Fig. C.

Make sure the drill press is connected to an outlet having
the same configuration as the plug. No adapter is available
or should be used when the drill press is converted for 230
volts. If the drill press must be reconnected for use on a different type of electrical circuit, the re-connection should be made
by qualified service personnel; and after re-connection, the tool should comply with all local codes and ordinances.

6

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating less than
150 volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A

,

the machine

will have a grounding plug that looks like the plug illustrated
in Fig. A

A temporary adapter, which looks like the adapter

illustrated in Fig. B, may be used to connect this plug to a
matching 2-conductor receptacle as shown in Fig. B if a
properly grounded outlet is not available. The temporary
adapter should be used only until a properly grounded outlet
can be installed by a qualified electrician. The green-colored
rigid ear, lug, and the like, extending from the adapter must
be connected to a permanent ground such as a properly
grounded outlet box. Whenever the adapter is used, it must
be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is equipped
with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into a matching outlet that is properly installed and grounded
in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

I m p ro p e r c o n n e c t i o n o f t h e e q u i p m e n t - g ro u n d i n g
con du c t or can result i n ri sk of e l ec tri c shoc k. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if
in doubt as to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding
type plugs and matching 3-conductor receptacles that
accept the machine’s plug, as shown in Fig. A.

Repair or replace damaged or worn cord immediately.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

IN ALL CASES, MAKE CERTAIN THAT THE
RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. IF YOU ARE NOT SURE,
HAVE A QUALIFIED ELECTRICIAN CHECK
THE RECEPTACLE.

Fig. C

3. Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating between
150 - 250 volts, inclusive:

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Fig. B

Fig. A

Summary of Contents for 17-925

Page 1: ...chinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 3582 16 1 2 V...

Page 2: ...stal Mail Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson TN 38305 IN CANADA 505 SOUTHGATE DRIVE GUELPH ONTARIO N1H 6M7 Information regarding the safe and proper operation of t...

Page 3: ...EMS The symbols below are used to help you recognize this information SAFETY GUIDELINES DEFINITIONS SOME DUST CREATED BY POWER SANDING SAWING GRINDING DRILLING AND OTHER CONSTRUCTION ACTIVITIES contai...

Page 4: ...to the machine and or injury may result 13 USE RECOMMENDED ACCESSORIES The use of accessories and attachments not recommended by Delta may cause damage to the machine or injury to the user 14 USE THE...

Page 5: ...table or by securing it against the drill press column Loss of control of the workpiece can cause serious injury 16 TURN THE MACHINE OFF AND WAIT FOR THE DRILL BIT CUTTING TOOL OR SANDING DRUM TO STOP...

Page 6: ...the adapter must be connected to a permanent ground such as a properly grounded outlet box Whenever the adapter is used it must be held in place with a metal screw NOTE In Canada the use of a temporar...

Page 7: ...hich will accept the machine s plug When using an extension cord be sure to use one heavy enough to carry the current of the machine An undersized cord will cause a drop in line voltage resulting in l...

Page 8: ...rm for Table Raising Mechanism 7 Table Raising and Lowering Handwheel 8 Table 9 Chuck 10 Chuck Key 11A Pinion Shaft Handles 3 For model 17 925 ONLY 11B Pinion Shaft Handle For Model 17 990X ONLY 12 Sp...

Page 9: ...ed in STEP 1 into the groove in the table bracket I Make certain that the teeth of the internal gear located inside the table bracket are engaged with the teeth of the raising rack F 4 Slide the raisi...

Page 10: ...hat the top of the raising rack F is under the bottom of the ring E and that enough clearance is available to allow the rack F to rotate around the column Tighten the set screw D with the supplied 3mm...

Page 11: ...t the chuck by tapping it with a soft tipped hammer T or a block of wood and hammer Fig 17 To avoid damage to the chuck NEVER drive the chuck onto the spindle with a metal hammer Fig 16 Fig 17 Thread...

Page 12: ...shers lockwashers and hex nuts C Fig 25 furnished with your drill press The holes for the carriage bolt heads and flat washers under the board must be countersunk so that the bolt heads are flush or b...

Page 13: ...ght or left by pulling out and removing the table alignment pin E Fig 31 Loosen the table locking bolt F tilt the table to the desired angle and tighten the bolt F When returning table to the level po...

Page 14: ...en you want to drill a number of holes to the same depth use the stop nut A Fig 34 on the threaded stop rod B DRILLING HOLES TO DEPTH DISCONNECT MACHINE FROM POWER SOURCE VARIABLE SPEED CONTROL Turn v...

Page 15: ...ng fit of the quill was adjusted at the factory After a long period of time play between the quill and head casting may develop To re adjust loosen the nut F Fig 36 and tighten the screw E Fig 35 with...

Page 16: ...ole and are designed for removal of wood chips Do not use hand bits which have a screw tip At drill press speeds they will lift and rotate the workpiece For through boring align the workpiece so that...

Page 17: ...BRICATION Oil the variable speed pulleys and the speed range shifter mechanism weekly Use a few drops of light machine oil in the two oil holes A Fig 38 located on top of the variable speed pulleys an...

Page 18: ...ssories should be used with this product ACCESSORIES SERVICE KEEP MACHINE CLEAN Periodically blow out all air passages with dry compressed air All plastic parts should be cleaned with a soft damp clot...

Page 19: ...Delta may require that electric motors be returned prepaid to a motor manufacturer s authorized station for inspection and repair or replacement Delta will not be responsible for any asserted defect...

Page 20: ...F brica Porter Cable Delta m s cercano ARIZONA Phoenix 85013 2906 4501 N 7th Ave Phone 602 279 6414 Fax 602 279 5470 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390 5555 Fax...

Reviews: