ELP AM Series - Manual 2011 - 042011
Copyright Delta UV
©
Page 2
CERTIFICATIONS
The Delta UV ELP range of Ultraviolet Sanitation Systems for pools, spas, water features and
ponds are certified and listed by the following independent laboratories and authorities.
Certifications can be independently confirmed by visiting the specific websites shown with each
certification below :
o
Listed under UL standard UL1081/UL1563 –US
o
Certified To Canadian CAN/CSA Standard C22.2 No. 218.1
o
MET Listing #
o
http://
o
Certified to NSF-50 Sanitation Standard
o
NSF Listing #
o
http://www.nsf.com/Certified/Pools/
o
EPA Established #075659-FRA-001
Delta UV declares to be in conformance with the applicable provisions of the Code of Federal
Regulations (CFR) requirements including Title 21, Chapter 1, Subchapter J pertaining to
radiological health.
All
Delta UV
systems are sized to match the maximum flow rate of the circulation pump(s).
Proper installation calls for 100% of the circulation system flow to pass through the UV reactor.
Slip stream or bypass installations which direct only a portion of the recirculation flow to pass
through the UV reactor cannot be guaranteed to produce the required sanitation and
dechloramination results and should be avoided.
Delta UV
systems are sized by confirming the
maximum GPM flow though the reactor to produce a dose of 60mJ/sec/cm
2
, which is the proper
UV-C dose for effective 99.99% (4 log minimum) kill rate for bacteria, algae and even chlorine
resistant parasites such as cryptosporidium, giardia, legionnella, and shigella.