UDG-4999 THERMosTAT

The UDG-4999 thermostat is an “all-in-one” programmable 
thermostat for electric in-floor heating control. 

PRECAUTIONS

Turn off the power to the heating system at the main 

• 

power panel to avoid electrical shock. 
Install

• 

 in compliance with the National and/or Local Elec-

trical Code. The UDG-4999 thermostat is equipped with 
a ground fault circuit interrupter (GFCI, Class A), which 
requires that the line and load be isolated from each other 
for correct operation.
The resistive load must not exceed 15A (1800 W at 120 

• 

VAC, 3120 W at 208 VAC, 3600 W at 240 VAC).

1. lOCATION

Locate the thermostat on the wall with free air circulation 
about 62” (1.6m) above the floor. Do not mount thermostat in 
direct sunlight. Refer to Detail 1.

2. INSTAllINg ThE ThERmISTOR IN ThE flOOR 

The UDG-4999 thermistor is used for temperature regulation 
of in-floor heating systems. Install the thermistor in a piece 
of 1/2” thin walled metal conduit, and place between heating 
cable runs. Refer to Detail 2.
If required, the thermistor cable can be extended up to 328’ 
(100m).

3. ThERmOSTAT CONNECTION 
Incoming Power Wiring

Delivers power from the service panel (breaker panel or 
fuse box) to the UDG-4999 thermostat. Connect line voltage 
wiring to the terminals (marked L1 and L2).

Cold lead Wiring

Delivers power from the UDG-4999 thermostat to the heating 
cable. Connect cold lead wiring to the load terminals (marked 
load and 15A).

Remove cover (open lock with a Phillips head screwdriver).

1. 

Connect wiring according to the directions above and  

2. 
  diagram on back of UDG-4999. Refer to Detail 3.

4. ThERmISTOR CONNECTION

Bring thermistor wire through the slot and connect to terminals 
marked “IN/SENSOR”, terminals C and D. Refer to Detail 4.

5. mOUNTINg ThE ThERmOSTAT 

Mount the UDG-4999 in the junction box, located on the wall.
Carefully replace the front cover by first positioning its upper 
edge and then clicking it into place.

Detail 2. 

Install thermistor between two cable runs.

62”

Detail 4. 

UDG-4999 thermistor connection.

1

2

3

4

L1(L)

L2(N)

LINE

120 / 240 VAC 

LOAD

1800W / 3600W  MAX  15A

5“

2“

2“

2“

2“

2“

2“

Thermistor

in conduit.

Detail 1. 

Do not mount thermostat in direct sunlight.

Detail 3. 

Remove cover and connect wiring.