Accessory 51E
Hiperface Interface Option
35
The low signal occurs approximately 6mS after the command is received at the Sincoder. The output will
go to high level to show the index mark present for the duration of the active index mark location. When
the Sincoder is removed from the index mark, the signal will go low for approximately 5mS and then
revert to the digital RS485 mode and await more Hiperface commands.
05Fh Set Sincoder to Index Output Permanently
This command sets the Sincoder to apply the index mark to the RS485 digital output lines.
The low signal occurs approximately 6mS after the command is received at the Sincoder. The output will
go to high level to show the index mark present for the duration of the active index mark location.
When power is removed from the Sincoder, it will revert to the digital RS485 mode.