background image

 

Specifications    

 

 

 

 

 

* Accuracy figures apply to calibration soils and over 0 to 60°C. 
  Percentages quoted as %vol are % volumetric water content.

 

Care and Safety  

 

Notices 

All parts of the SM200 design and documentation are the exclusive property of Delta-T 
Devices and covered under international copyright law, © 2005. Patent(s) pending. 
The SM200 product is CE compliant, conforming to EN61326:1997. 

 
 
 
 
 

 

Delta-T Devices Ltd 

128 Low Road 
Burwell  
Cambridge  CB5 0EJ 
England (UK)

 

Tel

:      

+44 1638 742922 

Fax

:     

+44 1638 743155 

E-mail

[email protected]

 

Web

:    

www.delta-t.co.uk

 

 

The rods of the SM200 are sharp in order to ease insertion.  Care must be 
taken and handling precautions followed.  

 

Avoid touching the rods or exposing them to other sources of static damage.  
Keep the SM200 in its protective tube when not in use. 

 

Take care when attaching cables to ensure that the connectors are clean, 
undamaged and properly aligned before pushing the parts together. 
Screw together firmly to ensure the connection is water-tight.  If the connector 
is damaged, apply a light smearing of silicon grease to maintain sealing.  

 

Do not pull the sensor out of the soil by its cable. 

 

If you feel strong resistance when inserting the SM200 into soil, it is likely you 
have encountered a stone.  Stop pushing and re-insert at a new location.  

 

Range and Notes 

Accuracy* 

±

 3 %vol 

0 to 50 %vol 

Salinity errors 

± 3.5 %vol 

0 to 40 %vol, over  

50 to 500 mS.m

-1

    

(0.5 to 5 dS.m

-1

Power requirement 

5 to 14V 
15mA typical 

1 second warm-up recommended  
200ms minimum 

Output signal 

0 to 1.0V 

Nominal 0 to 60 %vol 

Environmental sealing 

IP68  

Sensor buriable, sealed to IP68 

Operating range 

-20 to +60°C 

Readings in frozen soil are not meaningful 

 

Summary of Contents for SM200

Page 1: ...SM200 Soil Moisture Sensor Quick Start Guide Version 1 3 Delta T Devices Ltd ...

Page 2: ... 2005 Delta T Devices Ltd Page 2 SM200 overview 1 Cables 3 HH2 4 Data Loggers 2 Installation ...

Page 3: ...0 you have probably hit a stone Stop and re insert at a new location Installing at depth Auger a 45mm diameter hole 10 to vertical is recommended Fit insertion rod to SM200 remember to pass the cable through the insertion rod and fit the connector first Push the SM200 into the soil until rods are fully inserted Ensure good soil contact Backfill around the insertion rod Alternatively Dig a trench a...

Page 4: ...een press Set and scroll down to the Soil Type option Press Set again and scroll down to the appropriate soil type use Mineral for sand silt or clay soils or Organic for peaty soils Press Set to confirm this choice Choose the units you want for displaying readings At the start up screen press Set and scroll down to the Display option Press Set again and scroll down to select units Press Set to con...

Page 5: ...ure the GP1 by choosing SM200 from the sensor menu in PC DeltaLINK or Pocket DeltaLINK For configuration details see the GP1 Quick Start Guide DL6 Up to 6 SM200s can be connected to each DL6 with each sensor connected as a single ended powered sensor These details illustrate connection to Channel1 SM200 wiring Colour DL6 terminal Power V Red V Signal White IN Ground Shield IN and 0V Configure the ...

Page 6: ...nd Shield 58 and 61 Configure the DL2e by choosing one of the SM200 sensor codes from the LS2Win sensor library according to your soil type For configuration details see the DL2e User Manual Other data loggers The SM200 should be connected as a single ended powered sensor Configure the logger input as a voltage sensor approximately 0 to 1 0 volts corresponding to 0 to 60 water content see next sec...

Page 7: ... 0 1 V V V V V ε where V is the SM200 output in volts Linearisation table use for SM200 readings from 0 to 1 2 Volts V ε V ε V ε V ε V ε 0 000 1 011 0 120 2 461 0 260 3 442 0 820 5 936 1 150 7 661 0 030 1 447 0 150 2 718 0 310 3 700 0 960 6 586 1 200 8 039 0 060 1 832 0 180 2 946 0 400 4 105 1 040 6 991 1 220 8 264 0 090 2 168 0 220 3 211 0 600 4 953 1 100 7 333 1 800 9 000 Conversion from ε to So...

Page 8: ...amage Keep the SM200 in its protective tube when not in use Take care when attaching cables to ensure that the connectors are clean undamaged and properly aligned before pushing the parts together Screw together firmly to ensure the connection is water tight If the connector is damaged apply a light smearing of silicon grease to maintain sealing Do not pull the sensor out of the soil by its cable ...

Reviews: