Chemicals such as acetone, benzene, alcohol, thinner, ketones,

trichloroethylene, etc. must not come into contact with the hous-

ing to avoid chemical damage.

Please operate the Charging Screwdriver carefully in accordance 

with the operating instructions. Do not drop or subject the device 

to unnecessary impact.

When the device is running, do not change the forward

and reverse switch lever to avoid system error detection.

The mechanical wear of the device depends on the user’s torque, 

time or frequency. The greater the torque, the longer the time

or the higher the frequency, the faster the wear; after one month 

of use (8 hours every day, operating frequency 15Pcs/min) the 

minimum torque attenuation is about 2~3% of (the maximum is 

3~5%), and the attenuation will gradually decrease and be sta-

bilized over time. The user can periodically use a torque meter or 

torque wrench to determine if the torque output of the

device meets the application requirements.

Operating Function Summary

Summary of Contents for ESB4-SXI Series

Page 1: ...eries Automatic Shut off Precision Impact Driver USER MANUAL Delta Regis Tools Inc 7370 Commercial Circle Fort Pierce FL 34951 sales deltaregis com 1 888 500 2755 www deltaregis com Delta Regis_ESB4 S...

Page 2: ......

Page 3: ...s 5 Operating Instructions 5 Operating Function Summary 7 Function Description 10 1 Main panel buttons and screen display instructions 10 2 DR IRC1 Remote control overview 11 3 Operation function sett...

Page 4: ...cated to avoid danger 3 When the device is not in use remove the battery and store it in a dry and safe place 4 Please carefully set the device to appropriate torque according to the requirements of t...

Page 5: ...stall protection Low battery protection Forward and reverse three stage control protection Device sleep function if tool is unused for 3 min Operating Instructions 1 Before using this device please f...

Page 6: ...attached Please see table below DEVICE STATE ACTION FEEDBACK INCORRECT CORRECT Tool in active mode Press the trigger to exit sleep mode Indicator Lights Alternately flash red and green Green will fla...

Page 7: ...ierce FL 34951 772 465 4302 7 Operating Function Summary No Description 1 Trigger 2 Forward Reverse Switch 3 LED Work light 4 Bit Socket Holder 5 Aluminum Alloy Cover 6 Belt Hook Mount 7 Signal Displa...

Page 8: ...e counter clockwise Whenever the device is not in use leave the forward and reverse switch lever in the middle position Leave the forward and reverse switch lever in the middle position and press the...

Page 9: ...ot change the forward and reverse switch lever to avoid system error detection The mechanical wear of the device depends on the user s torque time or frequency The greater the torque the longer the ti...

Page 10: ...Quickly browse the setting of the running program Press and hold the button to enter the remote control setup mode Pc Button Quickly switch the running program Remember After switching programs press...

Page 11: ...mode display screen on the device will read SEr Program Choose Program P01 P05 1 Scroll through program with buttons Once on desired program you can select additional functions to add into specific p...

Page 12: ...h programs and add to sequence with button if desired Programs that were added to sequence will continue to cycle through in the order they were selected For example if you select P 0 1 and P 0 2 once...

Page 13: ...99 fas teners depending on application needs 2 Choose n0F only if you intend to turn off the screw count on the display Force Impact Force Setting Allows you to adjust the hammer strength based on app...

Page 14: ...OFF Once in secondary functions menu press the button on remote to toggle NG Confirm alert ON or OFF NG Confirm ON NG Confirm OFF OK All Confirm ON OFF Once in secondary functions menu press the butto...

Page 15: ...eased Stripped Screw If device drive continues to spin outside of normal parameters Red Light ON Top Continuous short beep until trigger is released Sleep Mode If device is unused for 180 sec sleep mo...

Page 16: ...ch is downward then push the device into the cover until it clips in 7 For testing this device it is recommended to use our company s specified testing equipment 8 This screwdriver is of clutch type m...

Page 17: ...b F02 H01 50 12 45 Nm 8 8 33 1 ftlb F01 H01 99 20 50 Nm 14 7 36 9 ftlb F01 H01 99 20 65 Nm 14 7 47 9 ftlb F01 H01 50 8 35 Nm 5 9 25 8 ftlb Weight Less Battery 1 02 kg 2 2 lbs 1 0 kg 2 2 lbs Recommende...

Page 18: ...M10 M12 M14 M16 M8 M10 M10 M12 M6 M8 M10 M12 Nm 8 40 Nm 20 70 Nm 20 90 Nm 28 100 Nm 8 30 Nm 8 40 Nm 20 60 Nm 20 70 Nm 3 20 Nm 3 20 Nm 5 30 Nm 12 50 ftlb 5 9 29 5 ftlb 14 7 51 6 ftlb 14 7 66 3 ftlb 20...

Page 19: ......

Page 20: ...www deltaregis com sales deltaregis com 7370 Commercial Circle Fort Pierce FL 34951 772 465 4302 20 ESB4 SXI Series...