background image

 

HD33[L]M.GSM

 

-   3   - 

V1.10

 

1

 

INTRODUCTION 

The HD33[L]M.GSM data logger allows several physical quantities to be monitored in a large 
variety of application fields: 

 

Temperature 

 

Relative humidity 

 

Atmospheric pressure 

 

Solar radiation 

 

Rainfall quantity 

 

Wind speed and direction 

It has 5 inputs: 

 

One input for relative humidity and temperature with NTC sensor combined probe or, 

alternatively, for temperature only probe with NTC sensor. 

 

One input for pyranometer. 

 

One input for rain gauge. 

 

One input for cup anemometer. 

 

One input for wind direction vane. 

It detects the atmospheric pressure by means of an 

optional

 internal sensor. 

If a relative humidity and temperature probe is connected, the dew point temperature is 
calculated. 

Only one probe of each type can be connected. 

The probes are connected through M12 

connectors. 
On request, one of the inputs can be replaced by a 4…20 mA analog input for the connection of 

a transmitter with current output, this allows the monitoring capability to be extended to many 
other quantities in addition to the ones mentioned above (for example, a level sensor can be 

connected). 
Thanks to GSM/GPRS transmission, the user will not have to remove the data logger from its 

position or reach the place where the data logger is installed to download the data measured 

with the PC: the instrument can send the data via 

e-mail

 or 

FTP

 and can upload the data on 

an 

HTTP

 server (for example the Delta OHM portal “

www.deltaohm.cloud

”). You can also 

make a direct GPRS TCP/IP connection with a remote PC which has an Internet connection. 
The data logger GSM functions can be remotely controlled by sending SMS messages. 
For each detected quantity, the user can set two alarm thresholds (high threshold and low 
threshold), the alarm hysteresis and a delay in the generation of the alarm. The overrun of the 

thresholds can be indicated by an audible signal of the data logger through an internal buzzer or 
signaled by alarm e-mails or SMS messages. 

HD35AP-S

 PC software, downloadable free of charge from the Delta OHM website, allows 

configuration of data logger, displaying measurements in real time both in graphical and 
numerical format, data download. The data transferred to the PC are entered into a database. 
The data logger operates with 7…30 Vdc direct power supply voltage and can be powered by a 
solar panel through an appropriate 

optional

 power supply unit. 

IP 67

 waterproof housing. 

Optional

 custom LCD display.

 

Summary of Contents for HD33[L]M.GSM

Page 1: ...Operating manual GSM Data Logger HD33 L M GSM Keep for future reference www deltaohm com English Companies Brands of GHM...

Page 2: ...TECHNICAL CHARACTERISTICS 5 4 MEASURING PROBES 7 5 SIM CARD 8 6 INSTALLATION 9 7 POWER SUPPLY 9 8 USB CONNECTION 10 9 HD35AP S SOFTWARE 10 10 SMS COMMANDS 11 11 GPRS TCP IP CONNECTION 13 12 STORAGE OF...

Page 3: ...o GSM GPRS transmission the user will not have to remove the data logger from its position or reach the place where the data logger is installed to download the data measured with the PC the instrumen...

Page 4: ...or LED red blinking indicates that the instrument is powered blinks green to signal the GSM activity 4 Custom LCD display The cyclic automatic scrolling of the measurements can be set with the HD35AP...

Page 5: ...Weight 1 kg approx including shield and fixing clamping Housing Dimensions 122 x 120 x 56 mm excluding external antenna Material Polycarbonate PC Protection degree IP 67 with protective cap on the US...

Page 6: ...tes to an hourly value For the other characteristics please refer to the data sheet of the chosen rain gauge A measurement compensation curve as a function of the rainfall rate can be configured Wind...

Page 7: ...lable Solar radiation The pyranometers LP PYRA 02 LP PYRA 03 LP PYRA 10 LP SILICON PYRA 04 etc with mV output signal can be connected Wind speed and direction For the measurement of wind speed and dir...

Page 8: ...t the SIM tray back in place and push the metal block in the direction of the arrow LOCK 6 Close again the housing by fixing the 4 front screws Through the HD35AP S software set the necessary informat...

Page 9: ...th direct voltage from 7 to 30 Vdc and can be powered by mains through the power supply unit HD32MT SWD or by a solar panel through the power supply unit HD32WSF S12 that includes a 12 Vdc 7 2 Ah batt...

Page 10: ...it is not powered by the PC USB port When the data logger is not connected to the PC replace the mini USB connector protective cap to ensure the watertight integrity of the instrument 9 HD35AP S SOFTW...

Page 11: ...of measurement data via FTP FTP OFF Deactivates the periodic download of measurement data via FTP FTP PERIOD period index Set the transmission interval via FTP where period index 0 15 min 1 30 min 2 1...

Page 12: ...date where YYYY year MM month DD day HH hour MM minutes SS seconds HTTP DL INTERVAL YYYY MM DD HH MM SS YYYY MM DD HH MM SS Uploads on the HTTP server all data between the specified dates where YYYY y...

Page 13: ...he Modem Router 4 Disconnect the data logger from the USB port 5 In the HD35AP S software select Tools Type of connection select the TCP server option and set the number of the port opened in the Mode...

Page 14: ...safety technical conditions The regular functioning and operational safety of these instruments can be ensured only if all normal safety measures as well as the specific measures described in this man...

Page 15: ...K sensor temperature probe Measuring range 40 105 C Probe stem AISI 304 14 mm length 150 mm Cable length 2 5 or 10 m standard 4 pole M12 female connector HD9007A 1 12 ring protection against solar rad...

Page 16: ...ion 0 2 mm 0 1 or 0 5 mm on request with order Normally closed output contact Power supply 12 Vdc or 24 Vdc 10 absorbed power 50 W HD2016 Weighing rain gauge area 400 cm2 3000 cc collecting reservoir...

Page 17: ...itions 40 60 C 0 100 RH Rod mounting Dimensions 210 x 120 mm HD54 9K Transverse mast kit including transverse mast 40 mm and L 1500 mm two extension bars 40 mm and accessories ACCESSORIES HD35AP CFR21...

Page 18: ...n be fixed on a flat base with screws or to the ground with pegs Foldable legs for the transport HD2005 20 1 Tripod kit with adjustable legs for installing environmental sensors pyranometers temperatu...

Page 19: ......

Page 20: ...third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic eq...

Page 21: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Page 22: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 10 10 10 2018...