29
10.
ORDER
CODES
HD2302.0
The kit is composed of the instrument HD2302.0, 3 1.5V alkaline batteries, oper-
ating manual, and case.
The probes must be ordered separately.
10.1
P
ROBES COMPLETE WITH
SICRAM
MODULE
LP 471 PHOT
Photometric probe for
ILLUMINANCE
measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, diffuser
for cosine correction, class B according to CIE n°69. Measurement range:
0.01 lux…200 10
3
lux.
LP 471 LUM 2
Photometric probe for
LUMINANCE
measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, vision an-
gle 2°. Measurement range: 0.1 cd/m
2
…2000 10
3
cd/m
2
.
LP 471 PAR
Quantum radiometric probe for the measurement of the photon flow across the
chlorophyll range
PAR
(Photosynthetically Active Radiation 400 nm…700 nm)
complete with SICRAM, measurement in mol/m
2
s, diffuser for cosine correc-
tion. Measurement range: 0.01 mol/m
2
s…10 10
3
mol/m
2
s
LP 471 RAD
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module; in the 400 nm…1050 nm spectral range, diffuser for cosine correction.
Measurement range: 0.1 10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVA
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module; in the 315 nm…400 nm, peak 360 nm,
UVA
spectral range, quartz dif-
fuser for cosine correction. Measurement range: 0.1 10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVB
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module, in the 280 nm…315 nm, peak 305 - 310 nm,
UVB
spectral range, quartz
diffuser for cosine correction. Measurement range: 0.1 10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVC
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module, in the 220 nm…280 nm, peak 260 nm,
UVC
spectral range, quartz dif-
fuser for cosine correction. Measurement range: 0.1 10
-3
W/m
2
…2000 W/m
2
.
LP 471 ERY
Radiometric probe for
EFFECTIVE TOTAL IRRADIANCE
measurement
(W
eff
/m
2
) weighted according to the UV action curve (CEI EN 60335-2-27) com-
plete with SICRAM module. Spectral range: 250 nm…400 nm, quartz diffuser
for cosine correction.
Measurement range: 0.1 10
-3
W
eff
/m
2
…2000 W
eff
/m
2
.
LP 471 BLUE
Radiometric probe for
EFFECTIVE IRRADIANCE
measurement in the spec-
tral range of Blue light complete with SICRAM module.
Spectral range 380nm…550nm, diffuser for cosine correction. Measurement
range: 0.1 10
-3
W/m
2
…2000 W/m
2
.
LP 471 P-A
Combined probe for measuring the
ILLUMINANCE
(lux), with standard pho-
topic spectral response, and for measuring the
IRRADIANCE
(μW/cm
2
) in the
UVA
spectral range (315-400 nm, with peak at 360 nm). Both sensors are
equipped with diffuser for the correction according to the cosine law.